The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
New Nanostructured TiO2 for Direct Electrochemistry and Glucose Sensor Applications
Abstract
A new, slack, and uniformly porous TiO 2 material is synthesized by a simple, carbon nanotube (CNT) template‐assisted hydrothermal method and is further explored for protein immobilization and biosensing. Results demonstrate that the material has a large specific surface area and a unique nanostructure with a uniform pore‐size distribution. Glucose oxidase (GOD) immobilized on the material exhibits facile, direct electrochemistry and good electrocatalytic performance without any electron mediator. The fabricated glucose oxidase sensor shows good stability and high sensitivity, which indicates that the slack porous TiO 2 is an attractive material for use in the fabrication of biosensors, particularly enzymatic sensors, because of its direct electrochemistry, high specific surface area, and unique nanostructure for efficient immobilization of biomolecules.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Laviron, E. (1979) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/s0022-0728(79)80075-3 · Cited by 7,234
Generalized syntheses of large-pore mesoporous metal oxides with semicrystalline frameworks
Yang, P., Zhao, D., Margolese, D. I., Chmelka, B. F., & Stucky, G. D. (1998) · Nature · doi:10.1038/24132 · Cited by 2,493
RajanBabu, T. V. (. (2001) · Encyclopedia of Reagents for Organic Synthesis · doi:10.1002/047084289x.re001 · Cited by 2,480
"Plugging into Enzymes": Nanowiring of Redox Enzymes by a Gold Nanoparticle
Xiao, Y., Patolsky, F., Katz, E., Hainfeld, J. F., & Willner, I. (2003) · Science · doi:10.1126/science.1080664 · Cited by 1,270
Protein Electrochemistry Using Aligned Carbon Nanotube Arrays
Gooding, J. J., Wibowo, R., Liu, Yang, W., Losic, D., Orbons, S., Mearns, F. J., Shapter, J. G., & Hibbert, D. B. (2003) · Journal of the American Chemical Society · doi:10.1021/ja035722f · Cited by 881
Zinc oxide nanocomb biosensor for glucose detection
Wang, J. X., Sun, X. W., Wei, A., Lei, Y., Cai, X. P., Li, C. M., & Dong, Z. L. (2006) · Applied Physics Letters · doi:10.1063/1.2210078 · Cited by 595
Self-citationZSM-5 Monolith of Uniform Mesoporous Channels
Tao, Y., Kanoh, H., & Kaneko, K. (2003) · Journal of the American Chemical Society · doi:10.1021/ja0299405 · Cited by 498
Liu, S., & Ju, H. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00172-6 · Cited by 471
Enzymatic glucose biosensor based on ZnO nanorod array grown by hydrothermal decomposition
Wei, A., Sun, X. W., Wang, J. X., Lei, Y., Cai, X. P., Li, C. M., Dong, Z. L., & Huang, W. (2006) · Applied Physics Letters · doi:10.1063/1.2356307 · Cited by 442
Self-citationLiu, J., Chou, A., Rahmat, W., Paddon‐Row, M. N., & Gooding, J. J. (2005) · Electroanalysis · doi:10.1002/elan.200403116 · Cited by 307
Cited by
Electrochemical Non-enzymatic Glucose Sensors: A Perspective and an Evaluation
Toghill, K. E., & Compton, R. G. (2010) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)15359-4 · Cited by 926
Pang, S.-Y., Wong, Y.-T., Yuan, S., Liu, Y., Tsang, M.-K., Yang, Z., Huang, H., Wong, W.-T., & Hao, J. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.9b02578 · Cited by 835
A Comprehensive Review of Glucose Biosensors Based on Nanostructured Metal-Oxides
Rahman, M. M., Ahammad, A. J. S., Jin, J.-H., Ahn, S. J., & Lee, J.-J. (2010) · Sensors · doi:10.3390/s100504855 · Cited by 762
Metal oxide nanoparticles in electrochemical sensing and biosensing: a review
George, J. M., Antony, A., & Mathew, B. (2018) · Microchimica Acta · doi:10.1007/s00604-018-2894-3 · Cited by 580
Recent advances in ZnO nanostructures and thin films for biosensor applications: Review
Arya, S. K., Saha, S., Ramirez-Vick, J. E., Gupta, V., Bhansali, S., & Singh, S. P. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.05.048 · Cited by 579
Metadata
- Authors
- Bao, S., Li, C. M., Zang, J., Cui, X., Qiao, Y., & Guo, J.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2008-02-22
- Volume
- 18
- Issue
- 4
- Pages
- 591-599
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W1980728657
- Cited by
- 446
- References
- 26
- FWCI
- 22.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: New Nanostructured TiO2 for Direct Electrochemistry and Glucose Sensor Applications. https://app.cochat.ai/papers/10.1002/adfm.200700728
- The paper
- Bao, S., Li, C. M., Zang, J., Cui, X., Qiao, Y., & Guo, J. (2008). New Nanostructured TiO2 for Direct Electrochemistry and Glucose Sensor Applications. Advanced Functional Materials. https://doi.org/10.1002/adfm.200700728
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.