An overview of glucose sensors is presented, with specific focus on the promise of non-enzymatic electrochemical glucose sensors. The review addresses their merits and shortfalls with respect to their commercially available enzymatic counterparts. The mechanisms for catalysis are evaluated, and the future of the systems discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electric Field Effect in Atomically Thin Carbon Films
Novoselov, K. S., Geim, A. K., Morozov, S. V., Jiang, D., Zhang, Y., Dubonos, S. V., Grigorieva, I. V., & Firsov, A. A. (2004) · Science · doi:10.1126/science.1102896 · Cited by 66,834
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Biosensors for real-time in vivo measurements
Wilson, G. S., & Gifford, R. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.003 · Cited by 660
Chen, X., Matsumoto, N., Hu, Y., & Wilson, G. S. (2002) · Analytical Chemistry · doi:10.1021/ac015628m · Cited by 120
Cited by
Recent advances in electrochemical non-enzymatic glucose sensors – A review
Hwang, D.-W., Lee, S., Seo, M., & Chung, T. D. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.05.051 · Cited by 788
A contact lens with embedded sensor for monitoring tear glucose level
Yao, H., Shum, A. J., Cowan, M., Lähdesmäki, I., & Parviz, B. A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.12.042 · Cited by 513
Advances in carbon nanotube based electrochemical sensors for bioanalytical applications
Vashist, S. K., Zheng, D., Al-Rubeaan, K., Luong, J. H. T., & Sheu, F.-S. (2011) · Biotechnology Advances · doi:10.1016/j.biotechadv.2010.10.002 · Cited by 448
Significance of nanomaterials in electrochemical glucose sensors: An updated review (2016-2020)
Sehit, E., & Altintas, Z. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112165 · Cited by 380
Recent advances in perovskite oxides for non-enzymatic electrochemical sensors: A review
He, J., Xu, X., Li, M., Zhou, S., & Zhou, W. (2023) · Analytica Chimica Acta · doi:10.1016/j.aca.2023.341007 · Cited by 98
Metadata
- Authors
- Toghill, K. E., & Compton, R. G.
- Venue
- International Journal of Electrochemical Science
- Publisher
- Elsevier BV
- Published
- 2010-09
- Volume
- 5
- Issue
- 9
- Pages
- 1246-1301
- ISSN
- 1452-3981 (ISSN-L)
- OpenAlex
- W11159070
- Cited by
- 926
- References
- 5
- FWCI
- 30.15
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrochemical Non-enzymatic Glucose Sensors: A Perspective and an Evaluation. https://app.cochat.ai/papers/10.1016/s1452-3981(23)15359-4
- The paper
- Toghill, K. E., & Compton, R. G. (2010). Electrochemical Non-enzymatic Glucose Sensors: A Perspective and an Evaluation. International Journal of Electrochemical Science. https://doi.org/10.1016/s1452-3981(23)15359-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.