The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Fluorescent Conjugated Polyelectrolytes for Bioimaging
Abstract
This Feature Article summarizes the recent advances of water‐soluble fluorescent conjugated polyelectrolytes (CPEs) in bioimaging. Apart from a brief overview of traditional linear CPEs, a special emphasis is placed on CPEs that can self‐assemble into or are born with three‐dimensional nano‐architectures, including grafted CPEs, hyperbranched CPEs, and polyhedral oligomeric silsesquioxanes(POSS)‐based CPE derivatives. These CPEs naturally form nanoparticles with sizes ranging from 3 to 100 nm in aqueous media, and possess reactive functional groups for bioconjugation or complexation with desired biorecognition elements. The tunable size, low cytotoxicity, good photostability, and ease of surface modification ultimately enable these CPEs with wide applications in in vitro intracellular protein sensing, cell detection, in vivo cell imaging and drug tracking. Moreover, traditional linear CPEs can be transformed into uniform nanoparticles by complexation with oppositely charged biomolecules to allow for cell detection and in situ drug release monitoring. The work featured herein not only reveals the important molecular design principles of CPEs for different imaging tasks, but also highlights the promising directions for the further development of CPE‐based imaging materials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A clearer vision for in vivo imaging
Weissleder, R. (2001) · Nature Biotechnology · doi:10.1038/86684 · Cited by 3,839
RGD AND OTHER RECOGNITION SEQUENCES FOR INTEGRINS
Ruoslahti, E. (1996) · Annual Review of Cell and Developmental Biology · doi:10.1146/annurev.cellbio.12.1.697 · Cited by 3,191
Thermo-sensitive polymeric micelles based on poly (N-isopropylacrylamide) as drug carriers
Wei, H., Cheng, S.-X., Zhang, X.-Z., & Zhuo, R.-X. (2009) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2009.05.002 · Cited by 718
Cited by
Polymer-encapsulated organic nanoparticles for fluorescence and photoacoustic imaging
Li, K., & Liu, B. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00014e · Cited by 987
Self-citationFeng, L., Zhu, C., Yuan, H., Liu, L., Lv, F., & Wang, S. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60036j · Cited by 873
Hong, G., Zou, Y., Antaris, A. L., Diao, S., Wu, D., Cheng, K., Zhang, X., Chen, C., Liu, B., He, Y., et al. (2014) · Nature Communications · doi:10.1038/ncomms5206 · Cited by 563
Self-citationLi, J., Rao, J., & Pu, K. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2017.11.025 · Cited by 469
Self-citationDiketopyrrolopyrrole‐Based Semiconducting Polymer Nanoparticles for In Vivo Photoacoustic Imaging
Pu, K., Mei, J., Jokerst, J. V., Hong, G., Antaris, A. L., Chattopadhyay, N., Shuhendler, A. J., Kurosawa, T., Zhou, Y., Gambhir, S. S., et al. (2015) · Advanced Materials · doi:10.1002/adma.201502285 · Cited by 332
Self-citation
Metadata
- Authors
- Pu, K., & Liu, B.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2011-08-15
- Volume
- 21
- Issue
- 18
- Pages
- 3408-3423
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W1995724714
- Cited by
- 257
- References
- 3
- FWCI
- 16.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluorescent Conjugated Polyelectrolytes for Bioimaging. https://app.cochat.ai/papers/10.1002/adfm.201101153
- The paper
- Pu, K., & Liu, B. (2011). Fluorescent Conjugated Polyelectrolytes for Bioimaging. Advanced Functional Materials. https://doi.org/10.1002/adfm.201101153
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.