Encapsulating Elastically Stretchable Neural Interfaces: Yield, Resolution, and Recording/Stimulation of Neural Activity
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A high‐resolution elastically stretchable microelectrode array (SMEA) for interfacing with neural tissue is described. The SMEA consists of an elastomeric substrate, such as poly(dimethylsiloxane) (PDMS), elastically stretchable gold conductors, and an electrically insulating encapsulating layer in which contact holes are opened. We demonstrate the feasibility of producing contact holes with 40 μm × 40 μm openings, show why the adhesion of the encapsulation layer to the substrate is weakened during contact hole fabrication, and provide remedies. These improvements result in greatly increased fabrication yield and reproducibility. An SMEA with 28 microelectrodes was fabricated. The contact holes (100 μm × 100 μm) in the encapsulation layer are only ∼10% the size of the previous generation, allowing a larger number of microelectrodes per unit area, thus affording the capability to interface with a smaller neural population per electrode. This new SMEA is used to record spontaneous and evoked activity in organotypic hippocampal tissue slices at 0% strain before stretching, at 5% and 10% equibiaxial strain, and again at 0% strain after relaxation. Stimulus–response curves at each strain level are measured. The SMEA shows excellent biocompatibility for at least two weeks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Chronic, multisite, multielectrode recordings in macaque monkeys
Nicolelis, M. A. L., Dimitrov, D., Carmena, J. M., Crist, R., Lehew, G., Kralik, J. D., & Wise, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1934665100 · Cited by 740
Subbaroyan, J., Martin, D. C., & Kipke, D. R. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/006 · Cited by 368
Cited by
25th Anniversary Article: A Soft Future: From Robots and Sensor Skin to Energy Harvesters
Bauer, S., Bauer‐Gogonea, S., Graz, I., Kaltenbrunner, M., Keplinger, C., & Schwödiauer, R. (2014) · Advanced Materials · doi:10.1002/adma.201303349 · Cited by 860
Hybrid 3D Printing of Soft Electronics
Valentine, A. D., Busbee, T. A., Boley, J. W., Raney, J. R., Chortos, A., Kotikian, A., Berrigan, J. D., Durstock, M. F., & Lewis, J. A. (2017) · Advanced Materials · doi:10.1002/adma.201703817 · Cited by 688
Topological supramolecular network enabled high-conductivity, stretchable organic bioelectronics
Jiang, Y., Zhang, Z., Wang, Y.-X., Li, D., Coen, C.-T., Hwaun, E., Chen, G., Wu, H.-C., Zhong, D., Niu, S., et al. (2022) · Science · doi:10.1126/science.abj7564 · Cited by 617
Materials for stretchable electronics
Wagner, S., & Bauer, S. (2012) · MRS Bulletin · doi:10.1557/mrs.2012.37 · Cited by 449
Self-citationA universal interface for plug-and-play assembly of stretchable devices
Jiang, Y., Ji, S., Sun, J., Huang, J., Li, Y., Zou, G., Salim, T., Wang, C., Li, W., Jin, H., et al. (2023) · Nature · doi:10.1038/s41586-022-05579-z · Cited by 422
Metadata
- Authors
- Graudejus, O., Morrison, B., Goletiani, C., Yu, Z., & Wagner, S.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2011-12-08
- Volume
- 22
- Issue
- 3
- Pages
- 640-651
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2150960406
- Cited by
- 50
- References
- 3
- FWCI
- 1.91
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.