The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
A Single Component Conducting Polymer Hydrogel as a Scaffold for Tissue Engineering
Open accessAbstract
Conducting polymers (CPs) have exciting potential as scaffolds for tissue engineering, typically applied in regenerative medicine applications. In particular, the electrical properties of CPs has been shown to enhance nerve and muscle cell growth and regeneration. Hydrogels are particularly suitable candidates as scaffolds for tissue engineering because of their hydrated nature, their biocompatibility, and their tissue‐like mechanical properties. This study reports the development of the first single component CP hydrogel that is shown to combine both electro‐properties and hydrogel characteristics. Poly(3‐thiopheneacetic acid) hydrogels were fabricated by covalently crosslinking the polymer with 1,1′‐carbonyldiimidazole (CDI). Their swelling behavior was assessed and shown to display remarkable swelling capabilities (swelling ratios up to 850%). The mechanical properties of the networks were characterized as a function of the crosslinking density and were found to be comparable to those of muscle tissue. Hydrogels were found to be electroactive and conductive at physiological pH. Fibroblast and myoblast cells cultured on the hydrogel substrates were shown to adhere and proliferate. This is the first time that the potential of a single component CP hydrogel has been demonstrated for cell growth, opening the way for the development of new tissue engineering scaffolds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Matrix elasticity directs stem cell lineage specification
Engler, A. J., Sen, S., Sweeney, H. L., & Discher, D. E. (2006) · Cell · doi:10.1016/j.cell.2006.06.044 · Cited by 13,915
The dielectric properties of biological tissues: I. Literature survey
Gabriel, C., Gabriel, S., & Corthout, E. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/001 · Cited by 3,156
Myotubes differentiate optimally on substrates with tissue-like stiffness
Engler, A. J., Griffin, M. A., Sen, S., Bönnemann, C. G., Sweeney, H. L., & Discher, D. E. (2004) · The Journal of Cell Biology · doi:10.1083/jcb.200405004 · Cited by 1,743
Ghasemi-Mobarakeh, L., Prabhakaran, M. P., Morshed, M., Nasr-Esfahani, M. H., Baharvand, H., Kiani, S., Al-Deyab, S. S., & Ramakrishna, S. (2011) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.383 · Cited by 698
Electroconductive hydrogels: Synthesis, characterization and biomedical applications
Guiseppi-Elie, A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.12.052 · Cited by 646
Richardson-Burns, S. M., Hendricks, J. L., Foster, B., Povlich, L. K., Kim, D.-H., & Martin, D. C. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.11.026 · Cited by 503
Synthesis of a Novel, Biodegradable Electrically Conducting Polymer for Biomedical Applications
Rivers, T. J., Hudson, T. W., & Schmidt, C. E. (2002) · Advanced Functional Materials · doi:10.1002/1616-3028(20020101)12:1<33::aid-adfm33>3.0.co;2-e · Cited by 423
Prospects of conducting polymers in biosensors
Malhotra, B. D., Chaubey, A., & Singh, S. P. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.04.055 · Cited by 372
Nuttelman, C. R., Mortisen, D. J., Henry, S. M., & Anseth, K. S. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200111)57:2<217::aid-jbm1161>3.0.co;2-i · Cited by 328
Review paper: Progress in the Field of Conducting Polymers for Tissue Engineering Applications
Bendrea, A.-D., Cianga, L., & Cianga, I. (2011) · Journal of Biomaterials Applications · doi:10.1177/0885328211402704 · Cited by 322
Cited by
Yuk, H., Lu, B., & Zhao, X. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00595h · Cited by 2,108
Yang, J. C., Mun, J., Kwon, S. Y., Park, S., Bao, Z., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201904765 · Cited by 1,641
Electrically conductive polymers and composites for biomedical applications
Kaur, G., Adhikari, R., Cass, P., Bown, M., & Gunatillake, P. (2015) · RSC Advances · doi:10.1039/c5ra01851j · Cited by 836
Conducting Polymers for Tissue Engineering
Guo, B., & Ma, P. X. (2018) · Biomacromolecules · doi:10.1021/acs.biomac.8b00276 · Cited by 835
He, J., Shi, M., Liang, Y., & Guo, B. (2020) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.124888 · Cited by 623
Metadata
- Authors
- Mawad, D., Stewart, E., Officer, D. L., Romeo, T., Wagner, P., Wagner, K., & Wallace, G. G.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2012-04-12
- Volume
- 22
- Issue
- 13
- Pages
- 2692-2699
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2138371775
- Cited by
- 285
- References
- 35
- FWCI
- 7.72
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Single Component Conducting Polymer Hydrogel as a Scaffold for Tissue Engineering. https://app.cochat.ai/papers/10.1002/adfm.201102373
- The paper
- Mawad, D., Stewart, E., Officer, D. L., Romeo, T., Wagner, P., Wagner, K., & Wallace, G. G. (2012). A Single Component Conducting Polymer Hydrogel as a Scaffold for Tissue Engineering. Advanced Functional Materials. https://doi.org/10.1002/adfm.201102373
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.