Abstract

Minimally invasive surgery often requires devices that can change their geometry or shape when placed inside the body. Here, the potential of thermoplastic temperature‐memory polymers (TMP) for the design of intelligent devices, which can be programmed by the clinician to individually adapt their shifting geometry and their response temperature Tsw to the patient's needs, is explored. Poly(ω‐pentadecalactone) as hard segments and poly(ϵ‐caprolactone) segments acting as crystallizable controlling units for the temperature‐memory effect (TME) are chosen to form multiblock copolymers PDLCL. These components are selected according to their thermal properties and their good biocompatibility. Response temperatures obtained under stress‐free and constant strain recovery can be systematically adjusted by variation of the deformation temperature in a temperature range from 32 °C to 65 °C, which is the relevant temperature range for medical applications. The working principle of TMP based instruments for minimally invasive surgical procedures is successfully demonstrated using three temperature‐memory catheter concepts: individually programmable TM‐catheter, an in‐situ programmable TM‐catheter, and an intelligent drainage catheter for gastroenterology.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adfm.201200211

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 143

Metadata

Authors
Kratz, K., Voigt, U., & Lendlein, A.
Venue
Advanced Functional Materials
Publisher
Wiley
Published
2012-04-16
Volume
22
Issue
14
Pages
3057-3065
ISSN
  • 1616-301X (ISSN-L)
  • 1616-3028
OpenAlex
W2047222227
Cited by
143
References
13
FWCI
23.52
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.