The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Room‐Temperature Nanosoldering of a Very Long Metal Nanowire Network by Conducting‐Polymer‐Assisted Joining for a Flexible Touch‐Panel Application
Abstract
As an alternative to the brittle and expensive indium tin oxide (ITO) transparent conductor, a very simple, room‐temperature nanosoldering method of Ag nanowire percolation network is developed with conducting polymer to demonstrate highly flexible and even stretchable transparent conductors. The drying conducting polymer on Ag nanowire percolation network is used as a nanosoldering material inducing strong capillary‐force‐assisted stiction of the nanowires to other nanowires or to the substrate to enhance the electrical conductivity, mechanical stability, and adhesion to the substrate of the nanowire percolation network without the conventional high‐temperature annealing step. Highly bendable Ag nanowire/conducting polymer hybrid films with low sheet resistance and high transmittance are demonstrated on a plastic substrate. The fabricated flexible transparent electrode maintains its conductivity over 20 000 cyclic bends and 5 to 10% stretching. Finally, a large area (A4‐size) transparent conductor and a flexible touch panel on a non‐flat surface are fabricated to demonstrate the possibility of cost‐effective mass production as well as the applicability to the unconventional arbitrary soft surfaces. These results suggest that this is an important step toward producing intelligent and multifunctional soft electric devices as friendly human/electronics interface, and it may ultimately contribute to the applications in wearable computers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Silver nanowire-polymer composite electrodes for efficient polymer solar cells
Yu, Z., Li, L., Zhang, Q., Hu, W., & Pei, Q. (2011) · Advanced Materials · doi:10.1002/adma.201101992 · Cited by 352
Cited by
Carbonized Silk Fabric for Ultrastretchable, Highly Sensitive, and Wearable Strain Sensors
Wang, C., Li, X., Gao, E., Jian, M., Xia, K., Wang, Q., Xu, Z., Ren, T., & Zhang, Y. (2016) · Advanced Materials · doi:10.1002/adma.201601572 · Cited by 916
Extremely Elastic Wearable Carbon Nanotube Fiber Strain Sensor for Monitoring of Human Motion
Ryu, S., Lee, P., Chou, J. B., Xu, R., Zhao, R., Hart, A. J., & Kim, S.-G. (2015) · ACS Nano · doi:10.1021/acsnano.5b00599 · Cited by 770
Self-citationKim, K. K., Hong, S., Cho, H. M., Lee, J., Suh, Y. D., Ham, J., & Ko, S. H. (2015) · Nano Letters · doi:10.1021/acs.nanolett.5b01505 · Cited by 626
Self-citationRecent Progress on Stretchable Electronic Devices with Intrinsically Stretchable Components
Trung, T. Q., & Lee, N. (2017) · Advanced Materials · doi:10.1002/adma.201603167 · Cited by 497
Review of Flexible Temperature Sensing Networks for Wearable Physiological Monitoring
Li, Q., Zhang, L., Tao, X., & Ding, X. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201601371 · Cited by 354
Metadata
- Authors
- Lee, J., Lee, P., Lee, H. B., Hong, S., Lee, I., Yeo, J., Lee, S. S., Kim, T., Lee, D., & Ko, S. H.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2013-04-05
- Volume
- 23
- Issue
- 34
- Pages
- 4171-4176
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2029278568
- Cited by
- 507
- References
- 1
- FWCI
- 28.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Room‐Temperature Nanosoldering of a Very Long Metal Nanowire Network by Conducting‐Polymer‐Assisted Joining for a Flexible Touch‐Panel Application. https://app.cochat.ai/papers/10.1002/adfm.201203802
- The paper
- Lee, J., Lee, P., Lee, H. B., Hong, S., Lee, I., Yeo, J., Lee, S. S., Kim, T., Lee, D., & Ko, S. H. (2013). Room‐Temperature Nanosoldering of a Very Long Metal Nanowire Network by Conducting‐Polymer‐Assisted Joining for a Flexible Touch‐Panel Application. Advanced Functional Materials. https://doi.org/10.1002/adfm.201203802
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.