Cited by 626Advanced Sensor and Energy Harvesting MaterialsNanomaterials and Printing TechnologiesNanowire Synthesis and Applications

Highly Sensitive and Stretchable Multidimensional Strain Sensor with Prestrained Anisotropic Metal Nanowire Percolation Networks

Kim, Kyun Kyu, Hong, Sukjoon, Cho, Hyun Min, Lee, Jinhwan, Suh, Young Duk, Ham, Jooyeun, Ko, Seung Hwan·2015·Nano Letters

Abstract

To overcome the limitation of the conventional single axis-strain sensor, we demonstrate a multidimensional strain sensor composed of two layers of prestrained silver nanowire percolation network with decoupled and polarized electrical response in principal and perpendicular directional strain. The information on strain vector is successfully measured up to 35% maximum strain with large gauge factor (>20). The potential of the proposed sensor as a versatile wearable device has been further confirmed.

Integrity signals

Registry

Crossref · 10.1021/acs.nanolett.5b01505

Cites

42 of 42 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The application of an array of such strain sensors in mapping the strain distribution was demonstrated.

    “The application of an array of such strain sensors in mapping the strain distribution was demonstrated.[50]”

    From Nanomaterial-Enabled Wearable Sensors for Healthcare (2018) · cites this paper as [50]

  • Stretching along the prestrain direction leads to flattening of the wavy structure, which accompanies an almost constant resistance.

    “Stretching along the prestrain direction leads to flattening of the wavy structure (Figure 4g), which accompanies an almost constant resistance.”

    From Nanomaterial-Enabled Wearable Sensors for Healthcare (2018) · cites this paper as [50]

  • Without the wavy structure, significant resistance change was observed when strain was applied along the perpendicular direction.

    “In contrast, without the wavy structure, significant resistance change was observed when the strain was applied along the perpendicular direction.”

    From Nanomaterial-Enabled Wearable Sensors for Healthcare (2018) · cites this paper as [50]

  • Wavy AgNW percolation networks introduced by a prestrain (100%) release-buckling process make a strain sensor only responsive to strain in one direction.

    “To make the strain sensor only responsive to strain in one direction, wavy AgNW percolation networks were introduced by a prestrain (100%)release-buckling process.[50]”

    From Nanomaterial-Enabled Wearable Sensors for Healthcare (2018) · cites this paper as [50]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Kim, K. K., Hong, S., Cho, H. M., Lee, J., Suh, Y. D., Ham, J., & Ko, S. H.
Affiliations
  • Seoul National University (KR)
  • Stanford University (US)
Corresponding author
Ko, Seung Hwan
Venue
Nano Letters
Published
2015-07-07
Volume
15
Issue
8
Pages
5240-5247
ISSN
  • 1530-6984 (ISSN-L)
  • 1530-6992
OpenAlex
W2432872509
Cited by
626
References
42
Citations by year
2026: 13 · 2025: 39 · 2024: 53 · 2023: 51 · 2022: 66 · 2021: 73 · 2020: 73 · 2019: 75 · 2018: 81 · 2017: 55 · 2016: 39 · 2015: 7 · 2013: 1
FWCI
30.19
Type
journal article
Language
en
Open access
closed
Locations
  • Nano Letters (publishedVersion)
  • PubMed (publishedVersion)
  • Seoul National University Open Repository (Seoul National University) (submittedVersion)
Funders
  • Institute of Advanced Machinery and Design, Seoul National University
  • National Research Foundation of Korea (2012-0008779, 2012-054172)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
  • Physical Sciences › Engineering › Biomedical Engineering › Nanowire Synthesis and Applications
Keywords
silver nanowires, stretchable electronics, wearable devices, gauge factor

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review