Cited by 770Advanced Sensor and Energy Harvesting MaterialsCarbon Nanotubes in CompositesNanomaterials and Printing Technologies

Extremely Elastic Wearable Carbon Nanotube Fiber Strain Sensor for Monitoring of Human Motion

Ryu, Seongwoo, Lee, Phillip, Chou, Jeffrey B., Xu, Ruize, Zhao, Rong, Hart, Anastasios John, Kim, Sang-Gook·2015·ACS Nano

Abstract

The increasing demand for wearable electronic devices has made the development of highly elastic strain sensors that can monitor various physical parameters an essential factor for realizing next generation electronics. Here, we report an ultrahigh stretchable and wearable device fabricated from dry-spun carbon nanotube (CNT) fibers. Stretching the highly oriented CNT fibers grown on a flexible substrate (Ecoflex) induces a constant decrease in the conductive pathways and contact areas between nanotubes depending on the stretching distance; this enables CNT fibers to behave as highly sensitive strain sensors. Owing to its unique structure and mechanism, this device can be stretched by over 900% while retaining high sensitivity, responsiveness, and durability. Furthermore, the device with biaxially oriented CNT fiber arrays shows independent cross-sensitivity, which facilitates simultaneous measurement of strains along multiple axes. We demonstrated potential applications of the proposed device, such as strain gauge, single and multiaxial detecting motion sensors. These devices can be incorporated into various motion detecting systems where their applications are limited to their strain.

Integrity signals

Registry

Crossref · 10.1021/acsnano.5b00599

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Strain sensors fabricated by dry-spinning CNT fibers onto a prestrained (100%) Ecoflex substrate exhibited a GF of 0.54 for strain below 400% and 64 for strain between 400% and 960%.

    “Strain sensors fabricated by dry-spinning CNT fibers onto a prestrained (100%) Ecoflex substrate exhibited a GF of 0.54 for strain below 400% and 64 for strain between 400% and 960% (Figure 4a).[53]”

    From Nanomaterial-Enabled Wearable Sensors for Healthcare (2018) · cites this paper as [53]

  • Dry-spun CNT fibers were able to detect biaxial strain up to 200% with low cross-sensitivity between the two axes.

    “A similar idea was applied for dry-spun CNT fibers, [53] which was able to detect biaxial strain up to 200% with a low cross-sensitivity between the two axes.”

    From Nanomaterial-Enabled Wearable Sensors for Healthcare (2018) · cites this paper as [53]

Cites

Flagged first, then by citations

1 of the 39 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Ryu, S., Lee, P., Chou, J. B., Xu, R., Zhao, R., Hart, A. J., & Kim, S.-G.
Affiliations
  • Singapore University of Technology and Design (SG)
  • Massachusetts Institute of Technology (US)
Corresponding author
Kim, Sang-Gook
Venue
ACS Nano
Published
2015-06-09
Volume
9
Issue
6
Pages
5929-5936
ISSN
  • 1936-0851 (ISSN-L)
  • 1936-086X
OpenAlex
W2404934666
Cited by
770
References
39
Citations by year
2026: 31 · 2025: 45 · 2024: 69 · 2023: 51 · 2022: 61 · 2021: 97 · 2020: 92 · 2019: 118 · 2018: 96 · 2017: 66 · 2016: 41 · 2015: 3
FWCI
34.17
Type
journal article
Language
en
Open access
closed
Locations
  • ACS Nano (publishedVersion)
  • PubMed (publishedVersion)
Funders
Massachusetts Institute of Technology
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Materials Science › Materials Chemistry › Carbon Nanotubes in Composites
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
Keywords
carbon nanotube fibers, strain sensors, wearable electronics, stretchable sensors, human motion monitoring, cross-sensitivity, conductive pathways, motion sensors
MeSH terms
Clothing, Elasticity, Electronics, Humans, Monitoring, Physiologic, Movement, Nanotechnology, Nanotubes, Carbon

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review