The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Ultrathin Nanogenerators as Self‐Powered/Active Skin Sensors for Tracking Eye Ball Motion
Abstract
Ultrathin piezoelectric nanogenerator (NG) with a total thickness of ≈16 μm is fabricated as an active or self‐powered sensor for monitoring local deformation on a human skin. The NG was based on an anodic aluminum oxide (AAO) as an insulating layer grown on a thin Al foil by anodization, on which a thin film made of aligned ZnO nanowire compacted arrays is grown by solution chemistry. The performance of the NG is characterized with the assistance of the finite element method (FEM) simulation. The extremely thin NG is attached on the surface of an eyelid, and its output voltage/current characterizes the motion of the eye ball underneath. Since there is no external power needed for the operation of the NG, this self‐powered or active sensor can be effective in monitoring sleeping behavior, brain activities, and spirit status of a person as well as any biological associated skin deformation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Eye movements in reading and information processing: 20 years of research
Rayner, K. (1998) · Psychological Bulletin · doi:10.1037/0033-2909.124.3.372 · Cited by 7,979
Piezoelectric Nanogenerators Based on Zinc Oxide Nanowire Arrays
Wang, Z. L., & Song, J. (2006) · Science · doi:10.1126/science.1124005 · Cited by 7,922
Self-citationEnergy Harvesting From Human and Machine Motion for Wireless Electronic Devices
Mitcheson, P. D., Yeatman, E. M., Rao, G. K., Holmes, A. S., & Green, T. C. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.927494 · Cited by 1,888
Functional neuroanatomy of human rapid-eye-movement sleep and dreaming
Maquet, P., Péters, J.-M., Aerts, J., Delfiore, G., Degueldre, C., Luxen, A., & Franck, G. (1996) · Nature · doi:10.1038/383163a0 · Cited by 1,168
Nanotechnology‐Enabled Energy Harvesting for Self‐Powered Micro‐/Nanosystems
Wang, Z. L., & Wu, W. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201201656 · Cited by 1,063
Self-citationEye tracking in HCI and usability research
Poole, A., & Ball, L. J. (2006) · Encyclopedia of Human Computer Interaction · doi:10.4018/978-1-59140-562-7.ch034 · Cited by 690
Cited by
Nanopatterned Textile-Based Wearable Triboelectric Nanogenerator
Seung, W., Gupta, M. K., Lee, K. Y., Shin, K.-S., Lee, J.-H., Kim, T. Y., Kim, S., Lin, J., Kim, J. H., & Kim, S.-W. (2015) · ACS Nano · doi:10.1021/nn507221f · Cited by 714
Mahapatra, S. D., Mohapatra, P. C., Aria, A. I., Christie, G., Mishra, Y. K., Hofmann, S., & Thakur, V. K. (2021) · Advanced Science · doi:10.1002/advs.202100864 · Cited by 642
Piezoelectric nanogenerators – a review of nanostructured piezoelectric energy harvesters
Briscoe, J., & Dunn, S. (2015) · Nano Energy · doi:10.1016/j.nanoen.2014.11.059 · Cited by 613
Fiber-Based Generator for Wearable Electronics and Mobile Medication
Zhong, J., Zhang, Y., Zhong, Q., Hu, Q., Hu, B., Wang, Z. L., & Zhou, J. (2014) · ACS Nano · doi:10.1021/nn501732z · Cited by 612
Self-citationRecent Progress on Piezoelectric and Triboelectric Energy Harvesters in Biomedical Systems
Zheng, Q., Shi, B., Li, Z., & Wang, Z. L. (2017) · Advanced Science · doi:10.1002/advs.201700029 · Cited by 566
Self-citation
Metadata
- Authors
- Lee, S., Hinchet, R., Lee, Y., Yang, Y., Lin, Z., Ardila, G., Montès, L., Mouis, M., & Wang, Z. L.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2013-10-14
- Volume
- 24
- Issue
- 8
- Pages
- 1163-1168
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2059698328
- Cited by
- 190
- References
- 6
- FWCI
- 8.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.