The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Inkjet‐Printed Flexible Gold Electrode Arrays for Bioelectronic Interfaces
Abstract
Bioelectronic interfaces require electrodes that are mechanically flexible and chemically inert. Flexibility allows pristine electrode contact to skin and tissue, and chemical inertness prevents electrodes from reacting with biological fluids and living tissues. Therefore, flexible gold electrodes are ideal for bioimpedance and biopotential measurements such as bioimpedance tomography, electrocardiography (ECG), electroencephalography (EEG), and electromyography (EMG). However, a manufacturing process to fabricate gold electrode arrays on plastic substrates is still elusive. In this work, a fabrication and low‐temperature sintering (≈200 °C) technique is demonstrated to fabricate gold electrodes. At low‐temperature sintering conditions, lines of different widths demonstrate different sintering speeds. Therefore, the sintering condition is targeted toward the widest feature in the design layout. Manufactured electrodes show minimum feature size of 62 μm and conductivity values of 5 × 10 6 S m−1. Utilizing the versatility of printing and plastic electronic processes, electrode arrays consisting of 31 electrodes with electrode‐to‐electrode spacing ranging from 2 to 7 mm are fabricated and used for impedance mapping of conformal surfaces at 15 kHz. Overall, the fabrication process of an inkjet‐printed gold electrode array that is electrically reproducible, mechanically robust, and promising for bioimpedance and biopotential measurements is demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Recent advances in flexible sensors for wearable and implantable devices
Pang, C., Lee, C., & Suh, K. (2013) · Journal of Applied Polymer Science · doi:10.1002/app.39461 · Cited by 457
Cited by
Wu, H., Yang, G., Zhu, K., Liu, S., Guo, W., Jiang, Z., & Li, Z. (2021) · Advanced Science · doi:10.1002/advs.202001938 · Cited by 395
Recent Progress in Inkjet‐Printed Thin‐Film Transistors
Chung, S., Cho, K., & Lee, T. (2019) · Advanced Science · doi:10.1002/advs.201801445 · Cited by 312
Khoshmanesh, F., Thurgood, P., Pirogova, E., Nahavandi, S., & Baratchi, S. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112946 · Cited by 204
Stephens-Fripp, B., Sencadas, V., Mutlu, R., & Alici, G. (2018) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2018.00179 · Cited by 29
Metadata
- Authors
- Khan, Y., Pavinatto, F. J., Lin, M. C., Liao, A., Swisher, S. L., Mann, K., Subramanian, V., Maharbiz, M. M., & Arias, A. C.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2015-12-10
- Volume
- 26
- Issue
- 7
- Pages
- 1004-1013
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2194345460
- Cited by
- 165
- References
- 2
- FWCI
- 5.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Inkjet‐Printed Flexible Gold Electrode Arrays for Bioelectronic Interfaces. https://app.cochat.ai/papers/10.1002/adfm.201503316
- The paper
- Khan, Y., Pavinatto, F. J., Lin, M. C., Liao, A., Swisher, S. L., Mann, K., Subramanian, V., Maharbiz, M. M., & Arias, A. C. (2016). Inkjet‐Printed Flexible Gold Electrode Arrays for Bioelectronic Interfaces. Advanced Functional Materials. https://doi.org/10.1002/adfm.201503316
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.