Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 231 of the 233 references it cites were found in a registry or an index.

Materials, Devices, and Systems of On‐Skin Electrodes for Electrophysiological Monitoring and Human–Machine Interfaces

Open access

Abstract

On‐skin electrodes function as an ideal platform for collecting high‐quality electrophysiological (EP) signals due to their unique characteristics, such as stretchability, conformal interfaces with skin, biocompatibility, and wearable comfort. The past decade has witnessed great advancements in performance optimization and function extension of on‐skin electrodes. With continuous development and great promise for practical applications, on‐skin electrodes are playing an increasingly important role in EP monitoring and human–machine interfaces (HMI). In this review, the latest progress in the development of on‐skin electrodes and their integrated system is summarized. Desirable features of on‐skin electrodes are briefly discussed from the perspective of performances. Then, recent advances in the development of electrode materials, followed by the analysis of strategies and methods to enhance adhesion and breathability of on‐skin electrodes are examined. In addition, representative integrated electrode systems and practical applications of on‐skin electrodes in healthcare monitoring and HMI are introduced in detail. It is concluded with the discussion of key challenges and opportunities for on‐skin electrodes and their integrated systems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/advs.202001938

Cites

231 of 231 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 A schematic illustration of desirable properties of on‐skin electrodes.
Figure 1 A schematic illustration of desirable properties of on‐skin electrodes.CC BY · PubMed Central
Figure 2 Metal thin film electrodes. a) On‐skin electrodes with serpentine design. Reproduced with permission.[ 55 ] Copyright 2016, Wiley‐VCH. b) Stretchable electrodes with UL‐Sil and fabrics. Reproduced with permission.[ 56 ] Copyright 2014, Springer Nature. c‐i) Epidermal electrode systems incorporating EMG/ECG sensors and ii) image of the on‐skin electronics integrated onto a tattoo. Reproduced with permission.[ 57 ] Copyright 2011, AAAS. d) A schematic of TCR electrodes and the magnified views of Peano curves (inset). Reproduced with permission.[ 58 ] Copyright 2015, National Academy of Sciences USA. e) Photographs of gold film electrodes with wrinkled structures on the plasticized silk substrate. Reproduced with permission.[ 60 ] Copyright 2018, Wiley‐VCH. f‐i) An illustration of optimized on‐skin electrodes and ii) an SEM image shows the superior conformality of a 5 µm thick membrane. Reproduced with permission.[ 61 ] Copyright 2013, Wiley‐VCH. g‐i) Multifunctional device consisting of EP sensors and ii) an image shows conformal skin‐electrode interfaces during compression. Reproduced with permission.[ 66 ] Copyright 2015, Wiley‐VCH. h) Images of the SCG and ECG sensors with excellent conformal contact with skin. Reproduced with permission.[ 67 ] Copyright 2019, Wiley‐VCH.
Figure 2 Metal thin film electrodes. a) On‐skin electrodes with serpentine design. Reproduced with permission.[ 55 ] Copyright 2016, Wiley‐VCH. b) Stretchable electrodes with UL‐Sil and fabrics. Reproduced with permission.[ 56 ] Copyright 2014, Springer Nature. c‐i) Epidermal electrode systems incorporating EMG/ECG sensors and ii) image of the on‐skin electronics integrated onto a tattoo. Reproduced with permission.[ 57 ] Copyright 2011, AAAS. d) A schematic of TCR electrodes and the magnified views of Peano curves (inset). Reproduced with permission.[ 58 ] Copyright 2015, National Academy of Sciences USA. e) Photographs of gold film electrodes with wrinkled structures on the plasticized silk substrate. Reproduced with permission.[ 60 ] Copyright 2018, Wiley‐VCH. f‐i) An illustration of optimized on‐skin electrodes and ii) an SEM image shows the superior conformality of a 5 µm thick membrane. Reproduced with permission.[ 61 ] Copyright 2013, Wiley‐VCH. g‐i) Multifunctional device consisting of EP sensors and ii) an image shows conformal skin‐electrode interfaces during compression. Reproduced with permission.[ 66 ] Copyright 2015, Wiley‐VCH. h) Images of the SCG and ECG sensors with excellent conformal contact with skin. Reproduced with permission.[ 67 ] Copyright 2019, Wiley‐VCH.CC BY · PubMed Central
Figure 3 Carbon material electrodes. a) Images of nine CNT/PDMS electrodes. Reproduced with permission.[ 72 ] Copyright 2012, IEEE. b) A schematic illustration of a CNTs/aPDMS ECG electrode. Reproduced with permission.[ 75 ] Copyright 2014, Springer Nature. c) The CNT/graphene electrode patch with the content of CNT and graphene at 9:1. Reproduced with permission.[ 76 ] Copyright 2016, American Chemical Society. d) A photograph of the graphene electronic tattoo containing EP sensors. Reproduced with permission.[ 82 ] Copyright 2017, American Chemical Society. e) rGO‐aPDMS electrodes for monitoring EP signals. Reproduced with permission.[ 85 ] Copyright 2020, Elsevier. f) EP electrodes with laser‐induced porous graphene. Reproduced with permission.[ 86 ] Copyright 2018, Wiley‐VCH.
Figure 3 Carbon material electrodes. a) Images of nine CNT/PDMS electrodes. Reproduced with permission.[ 72 ] Copyright 2012, IEEE. b) A schematic illustration of a CNTs/aPDMS ECG electrode. Reproduced with permission.[ 75 ] Copyright 2014, Springer Nature. c) The CNT/graphene electrode patch with the content of CNT and graphene at 9:1. Reproduced with permission.[ 76 ] Copyright 2016, American Chemical Society. d) A photograph of the graphene electronic tattoo containing EP sensors. Reproduced with permission.[ 82 ] Copyright 2017, American Chemical Society. e) rGO‐aPDMS electrodes for monitoring EP signals. Reproduced with permission.[ 85 ] Copyright 2020, Elsevier. f) EP electrodes with laser‐induced porous graphene. Reproduced with permission.[ 86 ] Copyright 2018, Wiley‐VCH.CC BY · PubMed Central
Figure 4 Electrodes based on Metallic nanomaterials. a‐i) On‐skin electrodes with Cu networked mesh structure (inset) and ii) schematic of Cu nanomesh electrodes. Reproduced with permission.[ 98 ] Copyright 2016, Wiley‐VCH. b‐i) Au nanomesh conductors and ii) the process of the polyvinyl alcohol nanofibers (PVA NFs) dissolution. Reproduced with permission.[ 44 ] Copyright 2017, Springer Nature . c‐i) A cross‐sectional SEM image of convoluted nanonetworks and ii) an image of the NEE intimately coupling with human skin. Reproduced with permission.[ 100 ] Copyright 2019, Wiley‐VCH. d‐i) SEM image of Ag‐PU network conductors, ii) an illustration of the hydrogen bonding, and iii) porous Ag‐PU electrodes on skin. Reproduced with permission.[ 101 ] Copyright 2019, Wiley‐VCH. e‐i) SEM image of the Ag flakes and Ag nanoparticle and ii) the ECCs‐based electrodes conformally attached to skin during compression. Reproduced with permission.[ 102 ] Copyright 2019, American Chemical Society. f‐i) SEM image of AgNW‐embedded aPDMS matrix and ii) the AgNWs‐aPDMS ECG electrodes on skin. Reproduced with permission.[ 103 ] Copyright 2018, American Chemical Society. g‐i) SEM image and backscattered electron (BSE) image (inset) of Ag–Au nanowires, ii) schematic illustrations of Ag–Au nanocomposites, and iii) photograph of Ag–Au nanocomposite EP electrodes. Reproduced with permission.[ 104 ] Copyright 2018, Springer Nature.
Figure 4 Electrodes based on Metallic nanomaterials. a‐i) On‐skin electrodes with Cu networked mesh structure (inset) and ii) schematic of Cu nanomesh electrodes. Reproduced with permission.[ 98 ] Copyright 2016, Wiley‐VCH. b‐i) Au nanomesh conductors and ii) the process of the polyvinyl alcohol nanofibers (PVA NFs) dissolution. Reproduced with permission.[ 44 ] Copyright 2017, Springer Nature . c‐i) A cross‐sectional SEM image of convoluted nanonetworks and ii) an image of the NEE intimately coupling with human skin. Reproduced with permission.[ 100 ] Copyright 2019, Wiley‐VCH. d‐i) SEM image of Ag‐PU network conductors, ii) an illustration of the hydrogen bonding, and iii) porous Ag‐PU electrodes on skin. Reproduced with permission.[ 101 ] Copyright 2019, Wiley‐VCH. e‐i) SEM image of the Ag flakes and Ag nanoparticle and ii) the ECCs‐based electrodes conformally attached to skin during compression. Reproduced with permission.[ 102 ] Copyright 2019, American Chemical Society. f‐i) SEM image of AgNW‐embedded aPDMS matrix and ii) the AgNWs‐aPDMS ECG electrodes on skin. Reproduced with permission.[ 103 ] Copyright 2018, American Chemical Society. g‐i) SEM image and backscattered electron (BSE) image (inset) of Ag–Au nanowires, ii) schematic illustrations of Ag–Au nanocomposites, and iii) photograph of Ag–Au nanocomposite EP electrodes. Reproduced with permission.[ 104 ] Copyright 2018, Springer Nature.CC BY · PubMed Central
Figure 5 Other Materials for on‐skin Electrodes. a‐i) PEDOT:PSS electrodes with different diameters for EEG recording and ii) schematic illustrations show the cross section and top view of the electrode. Reproduced with permission.[ 111 ] Copyright 2014, Wiley‐VCH. b) Printed PEDOT:PSS electrodes on commercial paper for ECG measurements. Reproduced with permission.[ 112 ] Copyright 2017, Wiley‐VCH. c‐i) Schematics of the hybrid Au/hydrogel composite electrode on a forefinger and ii) SEM image of the Au arrays of 0.2 mm × 0.2 mm square tiles. Reproduced with permission.[ 114 ] Copyright 2016, Elsevier. d‐i) Schematics of interlocked electrodes, ii) SEM of the interlocking layer, and iii) an image of interlocking electrodes on the upper arm. Reproduced with permission.[ 115 ] Copyright 2020, Wiley‐VCH. e) A photo showing seven different types of electrodes including hydrogel‐PDMS electrode (Ag/AgCl and steel electrode as control groups). Reproduced with permission.[ 116 ] Copyright 2019, Wiley‐VCH.
Figure 5 Other Materials for on‐skin Electrodes. a‐i) PEDOT:PSS electrodes with different diameters for EEG recording and ii) schematic illustrations show the cross section and top view of the electrode. Reproduced with permission.[ 111 ] Copyright 2014, Wiley‐VCH. b) Printed PEDOT:PSS electrodes on commercial paper for ECG measurements. Reproduced with permission.[ 112 ] Copyright 2017, Wiley‐VCH. c‐i) Schematics of the hybrid Au/hydrogel composite electrode on a forefinger and ii) SEM image of the Au arrays of 0.2 mm × 0.2 mm square tiles. Reproduced with permission.[ 114 ] Copyright 2016, Elsevier. d‐i) Schematics of interlocked electrodes, ii) SEM of the interlocking layer, and iii) an image of interlocking electrodes on the upper arm. Reproduced with permission.[ 115 ] Copyright 2020, Wiley‐VCH. e) A photo showing seven different types of electrodes including hydrogel‐PDMS electrode (Ag/AgCl and steel electrode as control groups). Reproduced with permission.[ 116 ] Copyright 2019, Wiley‐VCH.CC BY · PubMed Central
Figure 6 Electrodes with tuned adhesion. a‐i) Schematic illustrations of the liquid spray‐on‐bandage and ii) the multifunctional epidermal electronic system (EES) attached on forearm, the conditions of compression and stretch on skin and after wearing for a week. Reproduced with permission.[ 118 ] Copyright 2013, Wiley‐VCH. b‐i) Schematic illustrations of Ca‐modified hydrogel patch, which was ii) firmly attached to the forearm when subjected to tensile, compression, and twisting forces. Reproduced with permission.[ 121 ] Copyright 2018, Wiley‐VCH. c‐i) Illustrations of graphene‐based electrodes, ii) the SEM inset shows microstructures and comparison of adhesive force between 3M tape and bioinspired microstructures in repeated cycles. Reproduced with permission.[ 76 ] Copyright 2017, American Chemical Society. d‐i) Adhesion model for OIA attachment, ii) schematic illustrations, and iii) SEM images of OIA structure, and iv) ECG signals recording on wet skin in dynamic movements. Reproduced with permission.[ 135,136] Copyright 2017, Springer Nature; Copyright 2019, Wiley‐VCH. e‐i) Photograph of flexible ECG sensor on skin. Comparisons of peel forces of various silicone‐based adhesives with different ratios of H‐PDMS to V‐PDMS and MQ resin content. Reproduced with permission.[ 139 ] Copyright 2017, Wiley‐VCH. f‐i) Photograph of the on‐skin device and ii) correlation between PEIE concentration and adhesion. Reproduced with permission.[ 142 ] Copyright 2017, Wiley‐VCH. g‐i) Photograph of the GEPC‐based TEE and ii) schematic illustrations of the water‐triggered decomposition process, iii) comparisons of adhesion force before/during water treatment, and iv) the SNR of EMG signals obtained from the TEE and commercial patch during wet state. Reproduced with permission.[ 150 ] Copyright 2019, Wiley‐VCH.
Figure 6 Electrodes with tuned adhesion. a‐i) Schematic illustrations of the liquid spray‐on‐bandage and ii) the multifunctional epidermal electronic system (EES) attached on forearm, the conditions of compression and stretch on skin and after wearing for a week. Reproduced with permission.[ 118 ] Copyright 2013, Wiley‐VCH. b‐i) Schematic illustrations of Ca‐modified hydrogel patch, which was ii) firmly attached to the forearm when subjected to tensile, compression, and twisting forces. Reproduced with permission.[ 121 ] Copyright 2018, Wiley‐VCH. c‐i) Illustrations of graphene‐based electrodes, ii) the SEM inset shows microstructures and comparison of adhesive force between 3M tape and bioinspired microstructures in repeated cycles. Reproduced with permission.[ 76 ] Copyright 2017, American Chemical Society. d‐i) Adhesion model for OIA attachment, ii) schematic illustrations, and iii) SEM images of OIA structure, and iv) ECG signals recording on wet skin in dynamic movements. Reproduced with permission.[ 135,136] Copyright 2017, Springer Nature; Copyright 2019, Wiley‐VCH. e‐i) Photograph of flexible ECG sensor on skin. Comparisons of peel forces of various silicone‐based adhesives with different ratios of H‐PDMS to V‐PDMS and MQ resin content. Reproduced with permission.[ 139 ] Copyright 2017, Wiley‐VCH. f‐i) Photograph of the on‐skin device and ii) correlation between PEIE concentration and adhesion. Reproduced with permission.[ 142 ] Copyright 2017, Wiley‐VCH. g‐i) Photograph of the GEPC‐based TEE and ii) schematic illustrations of the water‐triggered decomposition process, iii) comparisons of adhesion force before/during water treatment, and iv) the SNR of EMG signals obtained from the TEE and commercial patch during wet state. Reproduced with permission.[ 150 ] Copyright 2019, Wiley‐VCH.CC BY · PubMed Central
Figure 7 a‐i) SEM image of a microperforated silicone layer with patterned Au mesh electrode, ii) SEM tilted view of a bilayer microperforated silicone support laminated on skin replica, and iii) comparisons of WVTR values of different silicone films and the value without a film. Reproduced with permission.[ 152 ] Copyright 2019, Springer Nature. b‐i) Photograph, ii) SEM image, and iii) WVTR of an EP sensor based on porous graphene and porous elastomer sponges. Reproduced with permission.[ 86 ] Copyright 2018, Wiley‐VCH. c‐i) Schematic illustrations and ii) SEM image of dual‐layer PU/c‐PVA electrospun membrane, and iii) directional water transport from the hydrophobic (PU) side to the hydrophilic (PVA) side. Reproduced with permission.[ 158 ] Copyright 2012, The Royal Society of Chemistry.
Figure 7 a‐i) SEM image of a microperforated silicone layer with patterned Au mesh electrode, ii) SEM tilted view of a bilayer microperforated silicone support laminated on skin replica, and iii) comparisons of WVTR values of different silicone films and the value without a film. Reproduced with permission.[ 152 ] Copyright 2019, Springer Nature. b‐i) Photograph, ii) SEM image, and iii) WVTR of an EP sensor based on porous graphene and porous elastomer sponges. Reproduced with permission.[ 86 ] Copyright 2018, Wiley‐VCH. c‐i) Schematic illustrations and ii) SEM image of dual‐layer PU/c‐PVA electrospun membrane, and iii) directional water transport from the hydrophobic (PU) side to the hydrophilic (PVA) side. Reproduced with permission.[ 158 ] Copyright 2012, The Royal Society of Chemistry.CC BY · PubMed Central
Figure 8 Large area, multichannel electrodes. a‐i) 5 × 5 interconnected electrode array ii) used for turning the fan or lamp on or off by squeezing the flexor or extensor muscles, and iii) two channel EMG signals measured from the flexor and extensor muscles (black) and corresponding control input signals (red). Reproduced with permission.[ 59 ] Copyright 2016, American Chemical Society. b‐i) 8‐channel sensor array and ii) an array laminated on the amputated upper limb of a subject for controlling prosthetic movements, iii) four sensor arrays covering the scalp of the subject, and iv) the scalp ERP map. Reproduced with permission.[ 152 ] Copyright 2019, Springer Nature. c‐i) 3 × 3 stretchable electrode array on the forearm and its 6 channels layout, ii) four gestures and the corresponding motion of the wheeled mobile robot. Reproduced with permission.[ 102 ] Copyright 2019, American Chemical Society.
Figure 8 Large area, multichannel electrodes. a‐i) 5 × 5 interconnected electrode array ii) used for turning the fan or lamp on or off by squeezing the flexor or extensor muscles, and iii) two channel EMG signals measured from the flexor and extensor muscles (black) and corresponding control input signals (red). Reproduced with permission.[ 59 ] Copyright 2016, American Chemical Society. b‐i) 8‐channel sensor array and ii) an array laminated on the amputated upper limb of a subject for controlling prosthetic movements, iii) four sensor arrays covering the scalp of the subject, and iv) the scalp ERP map. Reproduced with permission.[ 152 ] Copyright 2019, Springer Nature. c‐i) 3 × 3 stretchable electrode array on the forearm and its 6 channels layout, ii) four gestures and the corresponding motion of the wheeled mobile robot. Reproduced with permission.[ 102 ] Copyright 2019, American Chemical Society.CC BY · PubMed Central
Figure 9 Standalone on‐skin systems through integration. a‐i) A flexible sensing array with integrated FPCB, ii) schematic of the sensor array for multiplexed perspiration analysis, and iii) the smart wristband worn on forearm. Reproduced with permission.[ 174 ] Copyright 2016, Springer Nature. b‐i) The component side and ii) sensor side of an integrated wearable patch. Reproduced with permission.[ 175 ] Copyright 2016, Wiley‐VCH. c) The mechanoacoustic–electrophysiological sensing i) platform and ii) its stretchability. Reproduced with permission.[ 160 ] Copyright 2016, AAAS. d) The NFC‐enabled optoelectronic system. Reproduced with permission.[ 181 ] Copyright 2016, AAAS.
Figure 9 Standalone on‐skin systems through integration. a‐i) A flexible sensing array with integrated FPCB, ii) schematic of the sensor array for multiplexed perspiration analysis, and iii) the smart wristband worn on forearm. Reproduced with permission.[ 174 ] Copyright 2016, Springer Nature. b‐i) The component side and ii) sensor side of an integrated wearable patch. Reproduced with permission.[ 175 ] Copyright 2016, Wiley‐VCH. c) The mechanoacoustic–electrophysiological sensing i) platform and ii) its stretchability. Reproduced with permission.[ 160 ] Copyright 2016, AAAS. d) The NFC‐enabled optoelectronic system. Reproduced with permission.[ 181 ] Copyright 2016, AAAS.CC BY · PubMed Central
Figure 10 On‐skin electrodes for healthcare. a‐i) The mSC electrode system and ii) captured ECG and pulse signals, iii) the alarm function of the system. Reproduced with permission.[ 183 ] Copyright 2016, Wiley‐VCH. b‐i) On‐skin sensor patch with remote control unit and ii) comparisons with commercial sensors, iii) pilot study on a patient diagnosed with Parkinson's disease and dysphagia. Reproduced with permission.[ 189 ] Copyright 2019, AAAS. c‐i) On‐skin patches for recognizing mental fatigue, ii) prediction accuracy of different models, and iii) output fatigue level labels by the DT‐based model during daily mental works. Reproduced with permission.[ 164 ] Copyright 2020, American Chemical Society. d‐i) The chest‐mounted E‐tattoo and ii) captured ECG, SCG and STI signals, iii) the correlation between SBP/DBP and RAC measured by an e‐tattoo, and iv) continuous estimation of SBP and DBP by the SOMNO and EMAC tattoo. Reproduced with permission.[ 67 ] Copyright 2019, Wiley‐VCH.
Figure 10 On‐skin electrodes for healthcare. a‐i) The mSC electrode system and ii) captured ECG and pulse signals, iii) the alarm function of the system. Reproduced with permission.[ 183 ] Copyright 2016, Wiley‐VCH. b‐i) On‐skin sensor patch with remote control unit and ii) comparisons with commercial sensors, iii) pilot study on a patient diagnosed with Parkinson's disease and dysphagia. Reproduced with permission.[ 189 ] Copyright 2019, AAAS. c‐i) On‐skin patches for recognizing mental fatigue, ii) prediction accuracy of different models, and iii) output fatigue level labels by the DT‐based model during daily mental works. Reproduced with permission.[ 164 ] Copyright 2020, American Chemical Society. d‐i) The chest‐mounted E‐tattoo and ii) captured ECG, SCG and STI signals, iii) the correlation between SBP/DBP and RAC measured by an e‐tattoo, and iv) continuous estimation of SBP and DBP by the SOMNO and EMAC tattoo. Reproduced with permission.[ 67 ] Copyright 2019, Wiley‐VCH.CC BY · PubMed Central
Figure 11 Applications of on‐skin electrodes in HMI. a‐i) On‐skin devices on the bicep and tricep (inset) during control of the virtual arm and ii) accuracy associated with a virtual arm targeting task. Reproduced with permission.[ 55 ] Copyright 2016, Wiley‐VCH. b‐i) Quadrotor control by sEMG signals from forearms based on the control gestures and ii) sEMG signals acquired from forearms corresponding to four gestures. Reproduced with permission.[ 61 ] Copyright 2013, Wiley‐VCH. c‐i) LTE electrodes for EEG recordings and ii) demonstration of the spelling task based on the BCI. Reproduced with permission.[ 58 ] Copyright 2015, National Academy of Sciences USA. d) The AgPMS electrode BCI system for controlling a driverless car. Reproduced with permission.[ 163 ] Copyright 2019, American Chemical Society. e‐i) Flexible wireless electrode systems, ii) CNN and SVM test accuracy on using time‐domain data and frequency‐domain data, and iii) in vivo demonstration of the on‐skin BMI with human subjects. Reproduced with permission.[ 191 ] Copyright 2019, Springer Nature.
Figure 11 Applications of on‐skin electrodes in HMI. a‐i) On‐skin devices on the bicep and tricep (inset) during control of the virtual arm and ii) accuracy associated with a virtual arm targeting task. Reproduced with permission.[ 55 ] Copyright 2016, Wiley‐VCH. b‐i) Quadrotor control by sEMG signals from forearms based on the control gestures and ii) sEMG signals acquired from forearms corresponding to four gestures. Reproduced with permission.[ 61 ] Copyright 2013, Wiley‐VCH. c‐i) LTE electrodes for EEG recordings and ii) demonstration of the spelling task based on the BCI. Reproduced with permission.[ 58 ] Copyright 2015, National Academy of Sciences USA. d) The AgPMS electrode BCI system for controlling a driverless car. Reproduced with permission.[ 163 ] Copyright 2019, American Chemical Society. e‐i) Flexible wireless electrode systems, ii) CNN and SVM test accuracy on using time‐domain data and frequency‐domain data, and iii) in vivo demonstration of the on‐skin BMI with human subjects. Reproduced with permission.[ 191 ] Copyright 2019, Springer Nature.CC BY · PubMed Central
Figure 12 The skin‐electrode interface model of on‐skin electrodes.
Figure 12 The skin‐electrode interface model of on‐skin electrodes.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 233 references

Research works printed but not linked: 4

  1. Gallagher A. J., 2012, IRCOBI Conf., 40, 494
  2. Torres F., 2009, Clin. Cosmet. Invest. Dermatol., 2, 39
  3. Jagota A., 2011, Mater. Sci. Eng., R, 72, 253
  4. Zeng Z., 2020, ACS Sens.

Cited by

See all 446

Metadata

Authors
Wu, H., Yang, G., Zhu, K., Liu, S., Guo, W., Jiang, Z., & Li, Z.
Affiliations
  • State Key Laboratory of Digital Manufacturing Equipment and Technology (CN)
  • Fudan University (CN)
Corresponding author
  • Wu, Hao
  • Li, Zhuo
Venue
Advanced Science
Publisher
Wiley
Published
2020-12-04
Volume
8
Issue
2
Pages
2001938-2001938
ISSN
2198-3844 (ISSN-L)
OpenAlex
W3110558114
Cited by
395
References
233
Citations by year
2026: 56 · 2025: 95 · 2024: 77 · 2023: 69 · 2022: 59 · 2021: 38 · 2020: 1
FWCI
3.49
Type
journal article
Language
en
Open access
Locations
  • Advanced Science (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, other-oa)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
Funders
National Natural Science Foundation of China (51820105008, 91648115)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
Keywords
electrophysiological monitoring, human-machine interaction, wearable sensors, stretchable materials, biocompatibility, electrode adhesion, breathability, electrode materials, healthcare monitoring

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Materials, Devices, and Systems of On‐Skin Electrodes for Electrophysiological Monitoring and Human–Machine Interfaces. https://app.cochat.ai/papers/10.1002/advs.202001938
The paper
Wu, H., Yang, G., Zhu, K., Liu, S., Guo, W., Jiang, Z., & Li, Z. (2021). Materials, Devices, and Systems of On‐Skin Electrodes for Electrophysiological Monitoring and Human–Machine Interfaces. Advanced Science. https://doi.org/10.1002/advs.202001938

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.