The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Electrically Activated Paper Actuators
Open accessAbstract
This paper describes the design and fabrication of electrically controlled paper actuators that operate based on the dimensional changes that occur in paper when the moisture absorbed on the surface of the cellulose fibers changes. These actuators are called “Hygroexpansive Electrothermal Paper Actuators” (HEPAs). The actuators are made from paper, conducting polymer, and adhesive tape. They are lightweight, inexpensive, and can be fabricated using simple printing techniques. The central element of the HEPAs is a porous conducting path (used to provide electrothermal heating) that changes the moisture content of the paper and causes actuation. This conducting path is made by embedding a conducting polymer (PEDOT:PSS) within the paper, and thus making a paper/polymer composite that retains the porosity and hydrophilicity of paper. Different types of HEPAs (straight, precurved, and creased) achieved different types of motions (e.g., bending motion, accordion type motion). A theoretical model for their behavior is proposed. These actuators have been used for the manipulation of liquids and for the fabrication of an optical shutter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cellulose: Fascinating Biopolymer and Sustainable Raw Material
Klemm, D., Heublein, B., Fink, H., & Bohn, A. (2005) · Angewandte Chemie International Edition · doi:10.1002/anie.200460587 · Cited by 7,551
Cited by
Soft Actuators for Small-Scale Robotics
Hines, L., Petersen, K., Lum, G. Z., & Sitti, M. (2017) · Advanced Materials · doi:10.1002/adma.201603483 · Cited by 1,337
Recent Progress on Flexible Capacitive Pressure Sensors: From Design and Materials to Applications
Mishra, R. B., El‐Atab, N., Hussain, A. M., & Hussain, M. M. (2021) · Advanced Materials Technologies · doi:10.1002/admt.202001023 · Cited by 433
Flexible Electronics Based on Micro/Nanostructured Paper
Zhang, Y., Zhang, L., Cui, K., Ge, S., Cheng, X., Yan, M., Yu, J., & Liu, H. (2018) · Advanced Materials · doi:10.1002/adma.201801588 · Cited by 380
All Paper-Based Flexible and Wearable Piezoresistive Pressure Sensor
Gao, L., Zhu, C., Li, L., Zhang, C., Liu, J., Yu, H.-D., & Huang, W. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b07465 · Cited by 365
Functionalized Cellulose for Water Purification, Antimicrobial Applications, and Sensors
Bethke, K., Palantöken, S., Andrei, V., Roß, M., Raghuwanshi, V. S., Kettemann, F., Greis, K., Ingber, T. T. K., Stückrath, J. B., Valiyaveettil, S., et al. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201800409 · Cited by 269
Metadata
- Authors
- Hamedi, M. M., Campbell, V. E., Rothemund, P., Güder, F., Christodouleas, D. C., Bloch, J., & Whitesides, G. M.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2016-02-17
- Volume
- 26
- Issue
- 15
- Pages
- 2446-2453
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2286666480
- Cited by
- 174
- References
- 1
- FWCI
- 23.31
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.