Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 202

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Phosphorescent Polymeric Thermometers for In Vitro and In Vivo Temperature Sensing with Minimized Background Interference

Chen, Zejing, Zhang, Kenneth Yin, Tong, Xiao, Liu, Yahong, Hu, Changyong, Liu, Shujuan, Yu, Qi, Zhao, Qiang, Huang, Wei·2016·Advanced Functional Materials

Abstract

Temperature plays a crucial role in many biological processes. Accurate temperature determination is important for diagnosis and treatment of diseases. Autofluorescence is an unavoidable interference in luminescent bioimaging. Hence, a large amount of research works has been devoted to reducing background autofluorescence and improving signal‐to‐noise ratio (SNR) in biodetection. Herein, a dual‐emissive phosphorescent polymeric thermometer has been developed by incorporating two long‐lived phosphorescent iridium(III) complexes into an acrylamide‐based thermosensitive polymer. Upon increasing temperature, this polymer undergoes coil‐globule transition, which leads to a decrease in polarity of the microenvironment surrounding the iridium(III) complexes and hence brings about emission enhancement of both complexes. Owing to their different sensitivity to surrounding environment, the emission intensity ratio of the two complexes is correlated to the temperature. Thus, the polymer has been used for temperature determination in vitro and in vivo via ratiometric luminescence imaging. More importantly, by using the long‐lived phosphorescence of the polymer, temperature mapping in zebrafish has been demonstrated successfully with minimized autofluorescence interference and improved SNR via time‐resolved luminescence imaging. To the best of our knowledge, this is the first example to use photoluminescent thermometer for in vivo temperature sensing.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adfm.201600706

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 202

Metadata

Authors
Chen, Z., Zhang, K. Y., Tong, X., Liu, Y., Hu, C., Liu, S., Yu, Q., Zhao, Q., & Huang, W.
Venue
Advanced Functional Materials
Publisher
Wiley
Published
2016-04-09
Volume
26
Issue
24
Pages
4386-4396
ISSN
  • 1616-301X (ISSN-L)
  • 1616-3028
OpenAlex
W2319749963
Cited by
202
References
3
FWCI
11.35
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Phosphorescent Polymeric Thermometers for In Vitro and In Vivo Temperature Sensing with Minimized Background Interference. https://app.cochat.ai/papers/10.1002/adfm.201600706
The paper
Chen, Z., Zhang, K. Y., Tong, X., Liu, Y., Hu, C., Liu, S., Yu, Q., Zhao, Q., & Huang, W. (2016). Phosphorescent Polymeric Thermometers for In Vitro and In Vivo Temperature Sensing with Minimized Background Interference. Advanced Functional Materials. https://doi.org/10.1002/adfm.201600706

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.