The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Phosphorescent Polymeric Thermometers for In Vitro and In Vivo Temperature Sensing with Minimized Background Interference
Abstract
Temperature plays a crucial role in many biological processes. Accurate temperature determination is important for diagnosis and treatment of diseases. Autofluorescence is an unavoidable interference in luminescent bioimaging. Hence, a large amount of research works has been devoted to reducing background autofluorescence and improving signal‐to‐noise ratio (SNR) in biodetection. Herein, a dual‐emissive phosphorescent polymeric thermometer has been developed by incorporating two long‐lived phosphorescent iridium(III) complexes into an acrylamide‐based thermosensitive polymer. Upon increasing temperature, this polymer undergoes coil‐globule transition, which leads to a decrease in polarity of the microenvironment surrounding the iridium(III) complexes and hence brings about emission enhancement of both complexes. Owing to their different sensitivity to surrounding environment, the emission intensity ratio of the two complexes is correlated to the temperature. Thus, the polymer has been used for temperature determination in vitro and in vivo via ratiometric luminescence imaging. More importantly, by using the long‐lived phosphorescence of the polymer, temperature mapping in zebrafish has been demonstrated successfully with minimized autofluorescence interference and improved SNR via time‐resolved luminescence imaging. To the best of our knowledge, this is the first example to use photoluminescent thermometer for in vivo temperature sensing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Biology of Cancer: Metabolic Reprogramming Fuels Cell Growth and Proliferation
DeBerardinis, R. J., Lum, J. J., Hatzivassiliou, G., & Thompson, C. B. (2008) · Cell Metabolism · doi:10.1016/j.cmet.2007.10.002 · Cited by 4,088
Towards a molecular understanding of adaptive thermogenesis
Lowell, B. B., & Spiegelman, B. M. (2000) · Nature · doi:10.1038/35007527 · Cited by 1,630
Ke, G., Wang, C., Ge, Y., Zheng, N., Zhu, Z., & Yang, C. J. (2012) · Journal of the American Chemical Society · doi:10.1021/ja3082439 · Cited by 196
Cited by
Long-Lived Emissive Probes for Time-Resolved Photoluminescence Bioimaging and Biosensing
Zhang, K. Y., Yu, Q., Wei, H., Liu, S., Zhao, Q., & Huang, W. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00425 · Cited by 923
Self-citationRatiometric optical nanoprobes enable accurate molecular detection and imaging
Huang, X., Song, J., Yung, B. C., Huang, X., Xiong, Y., & Chen, X. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00612h · Cited by 820
Jiang, K., Wang, Y., Gao, X., Cai, C., & Lin, H. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201802441 · Cited by 630
Significance of Nanomaterials in Wearables: A Review on Wearable Actuators and Sensors
Jayathilaka, W. A. D. M., Qi, K., Qin, Y., Chinnappan, A., Serrano‐García, W., Baskar, C., Wang, H., He, J., Cui, S., Thomas, S. W., et al. (2019) · Advanced Materials · doi:10.1002/adma.201805921 · Cited by 627
Xie, Y., Ge, Y., Peng, Q., Li, C., Li, Q., & Li, Z. (2017) · Advanced Materials · doi:10.1002/adma.201606829 · Cited by 446
Metadata
- Authors
- Chen, Z., Zhang, K. Y., Tong, X., Liu, Y., Hu, C., Liu, S., Yu, Q., Zhao, Q., & Huang, W.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2016-04-09
- Volume
- 26
- Issue
- 24
- Pages
- 4386-4396
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2319749963
- Cited by
- 202
- References
- 3
- FWCI
- 11.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.