Transferred, Ultrathin Oxide Bilayers as Biofluid Barriers for Flexible Electronic Implants
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
The work presented here introduces a materials strategy that involves physically transferred, ultrathin layers of silicon dioxide (SiO 2) thermally grown on silicon wafers and then coated with hafnium oxide (HfO 2) by atomic layer deposition, as barriers that satisfy requirements for even the most challenging flexible electronic devices. Materials and physics aspects of hydrolysis and ionic transport associated with such bilayers define their performance and reliability characteristics. Systematic experimental studies and reactive diffusion modeling suggest that the HfO 2 film, even with some density of pinholes, slows dissolution of the underlying SiO 2 by orders of magnitude, independent of the concentration of ions in the surrounding biofluids. Accelerated tests that involve immersion in phosphate‐buffered saline solution at a pH of 7.4 and under a constant electrical bias demonstrate that this bilayer barrier can also obstruct the transport of ions that would otherwise cause drifts in the operation of the electronics. Theoretical drift–diffusion modeling defines the coupling of dissolution and ion diffusion, including their effects on device lifetime. Demonstrations of such barriers with passive and active components in thin, flexible electronic test structures highlight the potential advantages for wide applications in chronic biointegrated devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
An ultra-lightweight design for imperceptible plastic electronics
Kaltenbrunner, M., Sekitani, T., Reeder, J., Yokota, T., Kuribara, K., Tokuhara, T., Drack, M., Schwödiauer, R., Graz, I., Bauer-Gogonea, S., et al. (2013) · Nature · doi:10.1038/nature12314 · Cited by 2,485
Piezoelectricity of single-atomic-layer MoS2 for energy conversion and piezotronics
Wu, W., Wang, L., Li, Y., Zhang, F., Lin, L., Niu, S., Chenet, D., Zhang, X., Hao, Y., Heinz, T. F., et al. (2014) · Nature · doi:10.1038/nature13792 · Cited by 2,287
Soft Microfluidic Assemblies of Sensors, Circuits, and Radios for the Skin
Xu, S., Zhang, Y., Jia, L., Mathewson, K. E., Jang, K.-I., Kim, J., Fu, H., Huang, X., Chava, P., Wang, R., et al. (2014) · Science · doi:10.1126/science.1250169 · Cited by 1,199
Self-citationInjectable, Cellular-Scale Optoelectronics with Applications for Wireless Optogenetics
Kim, T.-I., McCall, J. G., Jung, Y. H., Huang, X., Siuda, E. R., Li, Y., Song, J., Song, Y. M., Pao, H. A., Kim, R.-H., et al. (2013) · Science · doi:10.1126/science.1232437 · Cited by 1,174
Self-citationCanales, A., Jia, X., Froriep, U. P., Koppes, R. A., Tringides, C. M., Selvidge, J., Lu, C., Hou, C., Wei, L., Fink, Y., et al. (2015) · Nature Biotechnology · doi:10.1038/nbt.3093 · Cited by 668
Xu, L., Gutbrod, S. R., Bonifas, A. P., Su, Y., Sulkin, M. S., Lu, N., Chung, H.-J., Jang, K.-I., Liu, Z., Ying, M., et al. (2014) · Nature Communications · doi:10.1038/ncomms4329 · Cited by 634
Self-citationWirelessly powered, fully internal optogenetics for brain, spinal and peripheral circuits in mice
Montgomery, K. L., Yeh, A. J., Ho, J. S., Tsao, V., Mohan Iyer, S., Grosenick, L., Ferenczi, E. A., Tanabe, Y., Deisseroth, K., Delp, S. L., et al. (2015) · Nature Methods · doi:10.1038/nmeth.3536 · Cited by 565
Kinetics of quartz dissolution in electrolyte solutions using a hydrothermal mixed flow reactor
Dove, P. M., & Crerar, D. A. (1990) · Geochimica et Cosmochimica Acta · doi:10.1016/0016-7037(90)90431-j · Cited by 463
Mechanisms of classical crystal growth theory explain quartz and silicate dissolution behavior
Dove, P. M., Han, N., & De Yoreo, J. J. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0507777102 · Cited by 321
Cited by
Chiang, C.-H., Won, S. M., Orsborn, A. L., Yu, K. J., Trumpis, M., Bent, B., Wang, C., Xue, Y., Min, S., Woods, V., et al. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aay4682 · Cited by 211
Self-citationRecent Advances in Materials, Devices, and Systems for Neural Interfaces
Won, S. M., Song, E., Zhao, J., Li, J., Rivnay, J., & Rogers, J. A. (2018) · Advanced Materials · doi:10.1002/adma.201800534 · Cited by 206
Self-citationConformable hybrid systems for implantable bioelectronic interfaces
Fallegger, F., Schiavone, G., & Lacour, S. P. (2020) · Advanced Materials · doi:10.1002/adma.201903904 · Cited by 113
Metadata
- Authors
- Song, E., Lee, Y. K., Li, R., Li, J., Jin, X., Yu, K. J., Xie, Z., Fang, H., Zhong, Y., Du, H., Zhang, J., Fang, G., Kim, Y., Yoon, Y., Alam, M. A., Mei, Y., Huang, Y., & Rogers, J. A.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2017-07-20
- Volume
- 28
- Issue
- 12
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2739218397
- Cited by
- 66
- References
- 11
- FWCI
- 3.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Transferred, Ultrathin Oxide Bilayers as Biofluid Barriers for Flexible Electronic Implants. https://app.cochat.ai/papers/10.1002/adfm.201702284
- The paper
- Song, E., Lee, Y. K., Li, R., Li, J., Jin, X., Yu, K. J., Xie, Z., Fang, H., Zhong, Y., Du, H., Zhang, J., Fang, G., Kim, Y., Yoon, Y., Alam, M. A., Mei, Y., Huang, Y., & Rogers, J. A. (2018). Transferred, Ultrathin Oxide Bilayers as Biofluid Barriers for Flexible Electronic Implants. Advanced Functional Materials. https://doi.org/10.1002/adfm.201702284
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.