The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Flexible Normal‐Tangential Force Sensor with Opposite Resistance Responding for Highly Sensitive Artificial Skin
Abstract
An electronic skin (e‐skin) that can detect both normal and tangential forces with a differentiable signals output is essential for wearable electronics. A flexible, stretchable, and highly sensitive tactile sensor is presented that enables the detection of both normal and tangential forces, with specific opposite and thus easily being differentiated resistance changing outputs. The e‐skin, which is based on two‐sublayered carbon nanotubes (CNTs)/graphene oxide (GO) hybrid 3D conductive networks, that are anchored on a thin porous polydimethylsiloxane (PDMS) layer, is synthesized via a porogen (GO wrapped NaCl) assisted self‐assembling process. The fabricated CNTs/GO@PDMS‐based e‐skin shows superior sensitivity (gauge factor of 2.26 under a pressure loading of 1 kPa) to tangential force, moderate sensitivity (−0.31 kPa−1 at 0.05–3.8 kPa, and −0.03 kPa−1 at 3.8–6.3 kPa, respectively) to normal force, and a high‐reproducible response over 5000 loading cycles including stretching, bending, and shearing. For applications, the e‐skin can not only detect wrist pulsing, discriminating different roughness of surfaces, but also produce an obvious responding to an extremely slight ticking (<20 mg) from a feather, and even can real‐timely monitor human's breath and music in rhythm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An ultra-lightweight design for imperceptible plastic electronics
Kaltenbrunner, M., Sekitani, T., Reeder, J., Yokota, T., Kuribara, K., Tokuhara, T., Drack, M., Schwödiauer, R., Graz, I., Bauer-Gogonea, S., et al. (2013) · Nature · doi:10.1038/nature12314 · Cited by 2,485
A wearable and highly sensitive pressure sensor with ultrathin gold nanowires
Gong, S., Schwalb, W., Wang, Y., Chen, Y., Tang, Y., Si, J., Shirinzadeh, B., & Cheng, W. (2014) · Nature Communications · doi:10.1038/ncomms4132 · Cited by 2,064
A flexible and highly sensitive strain-gauge sensor using reversible interlocking of nanofibres
Pang, C., Lee, G.-Y., Kim, T.-I., Kim, S. M., Kim, H. N., Ahn, S.-H., & Suh, K.-Y. (2012) · Nature Materials · doi:10.1038/nmat3380 · Cited by 1,695
Advances of flexible pressure sensors toward artificial intelligence and health care applications
Zang, Y., Zhang, F., Di, C.-A., & Zhu, D. (2015) · Materials Horizons · doi:10.1039/c4mh00147h · Cited by 1,272
Yang, Y., Zhang, H., Lin, Z.-H., Zhou, Y. S., Jing, Q., Su, Y., Yang, J., Chen, J., Hu, C., & Wang, Z. L. (2013) · ACS Nano · doi:10.1021/nn403838y · Cited by 798
Self-citationPark, J., Lee, Y., Hong, J., Lee, Y., Ha, M., Jung, Y., Lim, H., Kim, S. Y., & Ko, H. (2014) · ACS Nano · doi:10.1021/nn505953t · Cited by 649
Kim, K. K., Hong, S., Cho, H. M., Lee, J., Suh, Y. D., Ham, J., & Ko, S. H. (2015) · Nano Letters · doi:10.1021/acs.nanolett.5b01505 · Cited by 626
A Highly Elastic, Capacitive Strain Gauge Based on Percolating Nanotube Networks
Cohen, D. J., Mitra, D., Peterson, K., & Maharbiz, M. M. (2012) · Nano Letters · doi:10.1021/nl204052z · Cited by 501
Ha, M., Lim, S., Park, J., Um, D., Lee, Y., & Ko, H. (2015) · Advanced Functional Materials · doi:10.1002/adfm.201500453 · Cited by 395
Electronic Skin with Multifunction Sensors Based on Thermosensation
Zhao, S., & Zhu, R. (2017) · Advanced Materials · doi:10.1002/adma.201606151 · Cited by 273
Cited by
Flexible Hybrid Electronics for Digital Healthcare
Ma, Y., Zhang, Y., Cai, S., Han, Z., Liu, X., Wang, F., Cao, Y., Wang, Z., Li, H., Chen, Y., et al. (2020) · Advanced Materials · doi:10.1002/adma.201902062 · Cited by 620
Graphene-based wearable piezoresistive physical sensors
Zheng, Q., Lee, J.-H., Shen, X., Chen, X., & Kim, J.-K. (2020) · Materials Today · doi:10.1016/j.mattod.2019.12.004 · Cited by 486
Yang, J., Luo, S., Zhou, X., Li, J., Fu, J., Yang, W., & Wei, D. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b02049 · Cited by 433
A three-dimensionally architected electronic skin mimicking human mechanosensation
Liu, Z., Hu, X., Bo, R., Yang, Y., Cheng, X., Pang, W., Liu, Q., Wang, Y., Wang, S., Xu, S., et al. (2024) · Science · doi:10.1126/science.adk5556 · Cited by 411
Multimodal Sensors with Decoupled Sensing Mechanisms
Yang, R., Zhang, W., Tiwari, N., Yan, H., Li, T., & Cheng, H. (2022) · Advanced Science · doi:10.1002/advs.202202470 · Cited by 400
Metadata
- Authors
- Mu, C., Song, Y., Huang, W., Ran, A., Sun, R., Xie, W., & Zhang, H.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2018-03-08
- Volume
- 28
- Issue
- 18
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2793156678
- Cited by
- 240
- References
- 10
- FWCI
- 9.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Flexible Normal‐Tangential Force Sensor with Opposite Resistance Responding for Highly Sensitive Artificial Skin. https://app.cochat.ai/papers/10.1002/adfm.201707503
- The paper
- Mu, C., Song, Y., Huang, W., Ran, A., Sun, R., Xie, W., & Zhang, H. (2018). Flexible Normal‐Tangential Force Sensor with Opposite Resistance Responding for Highly Sensitive Artificial Skin. Advanced Functional Materials. https://doi.org/10.1002/adfm.201707503
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.