Cited by 649Advanced Sensor and Energy Harvesting MaterialsAdvanced Materials and MechanicsTactile and Sensory Interactions

Tactile-Direction-Sensitive and Stretchable Electronic Skins Based on Human-Skin-Inspired Interlocked Microstructures

Park, Jonghwa, Lee, Youngoh, Hong, Jaehyung, Lee, Youngsu, Ha, Minjeong, Jung, Youngdo, Lim, Hyuneui, Kim, Sung Youb +1 more·2014·ACS Nano

Abstract

Stretchable electronic skins with multidirectional force-sensing capabilities are of great importance in robotics, prosthetics, and rehabilitation devices. Inspired by the interlocked microstructures found in epidermal-dermal ridges in human skin, piezoresistive interlocked microdome arrays are employed for stress-direction-sensitive, stretchable electronic skins. Here we show that these arrays possess highly sensitive detection capability of various mechanical stimuli including normal, shear, stretching, bending, and twisting forces. Furthermore, the unique geometry of interlocked microdome arrays enables the differentiation of various mechanical stimuli because the arrays exhibit different levels of deformation depending on the direction of applied forces, thus providing different sensory output patterns. In addition, we show that the electronic skins attached on human skin in the arm and wrist areas are able to distinguish various mechanical stimuli applied in different directions and can selectively monitor different intensities and directions of air flows and vibrations.

Integrity signals

Registry

Crossref · 10.1021/nn505953t

Cites

52 of 52 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • A multifunctional sensor with interlocked microdome arrays exhibited a pressure sensitivity of 15.1 kPa-1, a shear-force sensitivity of 2.21 N-1 under a normal pressure of 65 Pa, and ultrahigh sensitivity to tensile strain (27.8 for strain of 0-40%, 1084 for 40-90%, and 9617 for 90-120%).

    “the multifunctional sensor with interlocked microdome arrays (Figure 5a) exhibited a pressure sensitivity of 15.1 kPa -1 , [141] a shear-force sensitivity of 2.21 N -1 under a normal pressure of 65 Pa and a ultrahigh sensitivity to tensile strain (i.e., 27.8 for strain of 0-40%, 1084 for 40-90%, and 9617 for 90-120%).[144]”

    From Nanomaterial-Enabled Wearable Sensors for Healthcare (2018) · cites this paper as [144]

  • A multitude of pressure sensing arrays have been demonstrated to capture the spatial pressure distributions induced by different sources, such as a static object placed onto the sensing array, gas flow, bouncing of a water droplet, finger touch, and acoustic vibration.

    “A multitude of pressure sensing arrays have been demonstrated to capture the spatial pressure distributions induced by different sources, such as a static object placed onto the sensing array, [57,139,141,158,203] gas flow, [141,144,153] bouncing of a water droplet (Figure 11a), [139] finger touch, [144,161] and acoustic vibration.[144,203]”

    From Nanomaterial-Enabled Wearable Sensors for Healthcare (2018) · cites this paper as [144]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Park, J., Lee, Y., Hong, J., Lee, Y., Ha, M., Jung, Y., Lim, H., Kim, S. Y., & Ko, H.
Affiliations
  • Ulsan National Institute of Science and Technology (KR)
  • Korea Institute of Machinery & Materials (KR)
Corresponding author
Ko, Hyunhyub
Venue
ACS Nano
Published
2014-11-18
Volume
8
Issue
12
Pages
12020-12029
ISSN
  • 1936-0851 (ISSN-L)
  • 1936-086X
OpenAlex
W1979369614
Cited by
649
References
52
Citations by year
2026: 34 · 2025: 37 · 2024: 64 · 2023: 73 · 2022: 61 · 2021: 72 · 2020: 77 · 2019: 73 · 2018: 55 · 2017: 48 · 2016: 36 · 2015: 19
FWCI
17.83
Type
journal article
Language
en
Open access
closed
Locations
  • ACS Nano (publishedVersion)
  • PubMed (publishedVersion)
  • Scholarworks@UNIST (Ulsan National Institute of Science and Technology) (submittedVersion)
Funders
  • Korea Institute of Machine & Materials (NK175B)
  • National Research Foundation of Korea (NRF-2011-0014965, NRF-2012K1A3A1A20031618)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Mechanical Engineering › Advanced Materials and Mechanics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
Keywords
tactile sensing, force sensing, shear force detection, airflow sensing, vibration sensing, wearable sensors
MeSH terms
Skin, Stress, Mechanical, Touch, Biomimetics, Mechanical Phenomena, Electrical Equipment and Supplies

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review