The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Flexible Weaving Constructed Self‐Powered Pressure Sensor Enabling Continuous Diagnosis of Cardiovascular Disease and Measurement of Cuffless Blood Pressure
Abstract
Pulse wave carries comprehensive information regarding the human cardiovascular system (CS), which is essential for directly capturing CS parameters. More importantly, cuffless blood pressure (BP) is one of the most critical markers in CS. Accurately measuring BP via the pulse wave for continuous and noninvasive diagnosis of a disease associated with hypertension remains a challenge and highly desirable. Here, a flexible weaving constructed self‐powered pressure sensor (WCSPS) is reported for measurement of the pulse wave and BP in a noninvasive manner. The WCSPS holds an ultrasensitivity of 45.7 mV Pa−1 with an ultrafast response time of less than 5 ms, and no performance degradation is observed after up to 40 000 motion cycles. Furthermore, a low power consumption sensor system is developed for precisely monitoring pulse wave from the fingertip, wrist, ear, and ankles. A practical measurement is performed with 100 people with ages spanning from 24 to 82 years and different health statuses. The discrepancy between the measured BP results using the WCSPS and that provided by the commercial cuff‐based device is about 0.87–3.65%. This work demonstrates an efficient and cost‐effective way for human health monitoring, which would be a competitive alternative to current complex cardiovascular monitoring systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A wearable and highly sensitive pressure sensor with ultrathin gold nanowires
Gong, S., Schwalb, W., Wang, Y., Chen, Y., Tang, Y., Si, J., Shirinzadeh, B., & Cheng, W. (2014) · Nature Communications · doi:10.1038/ncomms4132 · Cited by 2,064
Wang, X., Gu, Y., Xiong, Z., Cui, Z., & Zhang, T. (2014) · Advanced Materials · doi:10.1002/adma.201304248 · Cited by 1,398
Self-citationA review of fabrication and applications of carbon nanotube film-based flexible electronics
Park, S., Vosguerichian, M., & Bao, Z. (2013) · Nanoscale · doi:10.1039/c3nr33560g · Cited by 1,185
Conductive Fiber‐Based Ultrasensitive Textile Pressure Sensor for Wearable Electronics
Lee, J., Kwon, H., Seo, J., Shin, S., Koo, J. H., Pang, C., Son, S., Kim, J. H., Jang, Y. H., Kim, D. E., et al. (2015) · Advanced Materials · doi:10.1002/adma.201500009 · Cited by 1,152
Micro-cable structured textile for simultaneously harvesting solar and mechanical energy
Chen, J., Huang, Y., Zhang, N., Zou, H., Liu, R., Tao, C., Fan, X., & Wang, Z. L. (2016) · Nature Energy · doi:10.1038/nenergy.2016.138 · Cited by 1,060
Self-citationReviving Vibration Energy Harvesting and Self-Powered Sensing by a Triboelectric Nanogenerator
Chen, J., & Wang, Z. L. (2017) · Joule · doi:10.1016/j.joule.2017.09.004 · Cited by 1,021
Self-citationPu, X., Li, L., Liu, M., Jiang, C., Du, C., Zhao, Z., Hu, W., & Wang, Z. L. (2016) · Advanced Materials · doi:10.1002/adma.201504403 · Cited by 820
Self-citationThe velocity of pulse wave in man
Bramwell, J. C., & Hill, A. V. (1922) · Proceedings of the Royal Society of London. Series B, Containing Papers of a Biological Character · doi:10.1098/rspb.1922.0022 · Cited by 806
Highly Stretchable and Transparent Metal Nanowire Heater for Wearable Electronics Applications
Hong, S., Lee, H., Lee, J., Kwon, J., Han, S., Suh, Y. D., Cho, H., Shin, J., Yeo, J., & Ko, S. H. (2015) · Advanced Materials · doi:10.1002/adma.201500917 · Cited by 788
Flexible Nanocomposite Generator Made of BaTiO3 Nanoparticles and Graphitic Carbons
Park, K., Lee, M., Liu, Y., Moon, S., Hwang, G., Zhu, G., Kim, J. E., Kim, S. O., Kim, D. K., Wang, Z. L., et al. (2012) · Advanced Materials · doi:10.1002/adma.201200105 · Cited by 711
Self-citation
Cited by
Emerging Technologies of Flexible Pressure Sensors: Materials, Modeling, Devices, and Manufacturing
Huang, Y., Fan, X., Chen, S., & Zhao, N. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201808509 · Cited by 543
Self-citationMicroengineering Pressure Sensor Active Layers for Improved Performance
Ruth, S. R. A., Feig, V. R., Tran, H., & Bao, Z. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202003491 · Cited by 538
Machine-knitted washable sensor array textile for precise epidermal physiological signal monitoring
Fan, W., He, Q., Meng, K., Tan, X., Zhou, Z., Zhang, G., Yang, J., & Wang, Z. L. (2020) · Science Advances · doi:10.1126/sciadv.aay2840 · Cited by 516
Self-citationFlexible Wearable Sensors for Cardiovascular Health Monitoring
Chen, S., Qi, J., Fan, S., Qiao, Z., Yeo, J. C., & Lim, C. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100116 · Cited by 453
Artificial intelligence biosensors: Challenges and prospects
Jin, X., Liu, C., Xu, T., Su, L., & Zhang, X. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112412 · Cited by 399
Metadata
- Authors
- Meng, K., Chen, J., Li, X., Wu, Y., Fan, W., Zhou, Z., He, Q., Wang, X., Fan, X., Zhang, Y., Yang, J., & Wang, Z. L.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2018-12-12
- Volume
- 29
- Issue
- 5
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2904885888
- Cited by
- 409
- References
- 39
- FWCI
- 16.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Flexible Weaving Constructed Self‐Powered Pressure Sensor Enabling Continuous Diagnosis of Cardiovascular Disease and Measurement of Cuffless Blood Pressure. https://app.cochat.ai/papers/10.1002/adfm.201806388
- The paper
- Meng, K., Chen, J., Li, X., Wu, Y., Fan, W., Zhou, Z., He, Q., Wang, X., Fan, X., Zhang, Y., Yang, J., & Wang, Z. L. (2019). Flexible Weaving Constructed Self‐Powered Pressure Sensor Enabling Continuous Diagnosis of Cardiovascular Disease and Measurement of Cuffless Blood Pressure. Advanced Functional Materials. https://doi.org/10.1002/adfm.201806388
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.