The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
All‐Nanofiber Self‐Powered Skin‐Interfaced Real‐Time Respiratory Monitoring System for Obstructive Sleep Apnea‐Hypopnea Syndrome Diagnosing
Abstract
Human respiration is an indispensable physiological behavior of the body, which is an important indicator to evaluate health status, especially for sleep‐related diseases. A real‐time respiratory monitoring and sleep breathing detecting system with convenience, high sensitivity, simple fabrication, and wearing comfort still remains a challenge and urgently desirable. Here, a breathable, highly sensitive, and self‐powered electronic skin (e‐skin) based on a triboelectric nanogenerator (TENG) is reported for real‐time respiratory monitoring and obstructive sleep apnea‐hypopnea syndrome (OSAHS) diagnosis. By using multilayer polyacrylonitrile and “polyamide 66” nanofibers as the contact pairs, and deposited gold as the electrodes, a contact‐separation type of TENG‐based all‐nanofiber e‐skin is developed. The e‐skin has a peak power density of 330 mW m−2, high pressure sensitivity of 0.217 kPa−1, excellent working stability, and good air permeability. Therefore, the e‐skin is simultaneously capable of energy autonomy and accurate real‐time subtle respiration monitoring. Meanwhile, a self‐powered diagnostic system for real‐time detection and severity evaluation of obstructive sleep apnea‐hypopnea syndrome are further developed to prevent the occurrence of OSAHS, delay its development, and improve sleep quality. This study hopes to pave a new and practical pathway for real‐time respiration monitoring and sleep breathing diseases clinical detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
Wang, Z. L. (2014) · Faraday Discuss. · doi:10.1039/c4fd00159a · Cited by 1,749
Self-citationYang, J. C., Mun, J., Kwon, S. Y., Park, S., Bao, Z., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201904765 · Cited by 1,641
Sustainably powering wearable electronics solely by biomechanical energy
Wang, J., Li, S., Yi, F., Zi, Y., Lin, J., Wang, X., Xu, Y., & Wang, Z. L. (2016) · Nature Communications · doi:10.1038/ncomms12744 · Cited by 648
Self-citationPhysiologic Effects of High-Flow Nasal Cannula in Acute Hypoxemic Respiratory Failure
Mauri, T., Turrini, C., Eronia, N., Grasselli, G., Volta, C. A., Bellani, G., & Pesenti, A. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201605-0916oc · Cited by 641
Wearable humidity sensor based on porous graphene network for respiration monitoring
Pang, Y., Jian, J., Tu, T., Yang, Z., Ling, J., Li, Y., Wang, X., Qiao, Y., Tian, H., Yang, Y., et al. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.05.038 · Cited by 369
Cited by
Cheng, T., Shao, J., & Wang, Z. L. (2023) · Nature Reviews Methods Primers · doi:10.1038/s43586-023-00220-3 · Cited by 609
Self-citationNing, C., Cheng, R., Jiang, Y., Sheng, F., Yi, J., Shen, S., Zhang, Y., Peng, X., Dong, K., & Wang, Z. L. (2022) · ACS Nano · doi:10.1021/acsnano.1c09792 · Cited by 279
Self-citationPorous Conductive Textiles for Wearable Electronics
Ding, Y., Jiang, J., Wu, Y., Zhang, Y., Zhou, J., Zhang, Y., Huang, Q., & Zheng, Z. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00507 · Cited by 269
Self-citationTriboelectric nanogenerators as wearable power sources and self-powered sensors
Pu, X., Zhang, C., & Wang, Z. L. (2023) · National Science Review · doi:10.1093/nsr/nwac170 · Cited by 267
Self-citationWang, H., Qiu, X., Li, B., Tan, X., & Huang, J. (2025) · Complex & Intelligent Systems · doi:10.1007/s40747-024-01648-0 · Cited by 15
Metadata
- Authors
- Peng, X., Dong, K., Ning, C., Cheng, R., Yi, J., Zhang, Y., Sheng, F., Wu, Z., & Wang, Z. L.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2021-06-19
- Volume
- 31
- Issue
- 34
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W3176592315
- Cited by
- 210
- References
- 6
- FWCI
- 10.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: All‐Nanofiber Self‐Powered Skin‐Interfaced Real‐Time Respiratory Monitoring System for Obstructive Sleep Apnea‐Hypopnea Syndrome Diagnosing. https://app.cochat.ai/papers/10.1002/adfm.202103559
- The paper
- Peng, X., Dong, K., Ning, C., Cheng, R., Yi, J., Zhang, Y., Sheng, F., Wu, Z., & Wang, Z. L. (2021). All‐Nanofiber Self‐Powered Skin‐Interfaced Real‐Time Respiratory Monitoring System for Obstructive Sleep Apnea‐Hypopnea Syndrome Diagnosing. Advanced Functional Materials. https://doi.org/10.1002/adfm.202103559
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.