The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Helical Fiber Strain Sensors Based on Triboelectric Nanogenerators for Self-Powered Human Respiratory Monitoring
Abstract
Respiration is a major vital sign, which can be used for early illness diagnosis and physiological monitoring. Wearable respiratory sensors present an exciting opportunity to monitor human respiratory behaviors in a real-time, noninvasive, and comfortable way. Among them, fiber-shaped triboelectric nanogenerators (FS-TENGs) are attractive for their comfort and high degree of freedom. However, the single-electrode FS-TENGs cannot respond to their own tensile strains, and the coaxial double-electrode FS-TENGs show low sensitivity to strain due to structural limitations. Here, a type of helical fiber strain sensor (HFSS) is developed, which can respond to tiny tensile strains. In addition, a smart wearable real-time respiratory monitoring system is developed based on the HFSSs, which can measure some key breathing parameters for disease prevention and medical diagnosis. An intelligent alarm can automatically call a preset mobile phone for help in response to respiratory behavior changes. This work provides an effective helical structure for fabricating highly sensitive strain sensors based on FS-TENGs and develops wearable self-powered real-time respiratory monitoring systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Flexible triboelectric generator
Fan, F.-R., Tian, Z.-Q., & Lin Wang, Z. (2012) · Nano Energy · doi:10.1016/j.nanoen.2012.01.004 · Cited by 6,705
Trung, T. Q., & Lee, N. (2016) · Advanced Materials · doi:10.1002/adma.201504244 · Cited by 2,160
On Maxwell's displacement current for energy and sensors: the origin of nanogenerators
Wang, Z. L. (2017) · Materials Today · doi:10.1016/j.mattod.2016.12.001 · Cited by 2,083
Self-citationFan, F.-R., Lin, L., Zhu, G., Wu, W., Zhang, R., & Wang, Z. L. (2012) · Nano Letters · doi:10.1021/nl300988z · Cited by 1,985
Self-citationDong, K., Peng, X., & Wang, Z. L. (2020) · Advanced Materials · doi:10.1002/adma.201902549 · Cited by 1,322
Self-citationPeng, X., Dong, K., Ye, C., Jiang, Y., Zhai, S., Cheng, R., Liu, D., Gao, X., Wang, J., & Wang, Z. L. (2020) · Science Advances · doi:10.1126/sciadv.aba9624 · Cited by 885
Self-citationImani, S., Bandodkar, A. J., Mohan, A. M. V., Kumar, R., Yu, S., Wang, J., & Mercier, P. P. (2016) · Nature Communications · doi:10.1038/ncomms11650 · Cited by 861
On the first principle theory of nanogenerators from Maxwell's equations
Wang, Z. L. (2020) · Nano Energy · doi:10.1016/j.nanoen.2019.104272 · Cited by 707
Self-citationWearable and Stretchable Strain Sensors: Materials, Sensing Mechanisms, and Applications
Souri, H., Banerjee, H., Jusufi, A., Radacsi, N., Stokes, A. A., Park, I., Sitti, M., & Amjadi, M. (2020) · Advanced Intelligent Systems · doi:10.1002/aisy.202000039 · Cited by 681
Swanney, M. P., Ruppel, G., Enright, P. L., Pedersen, O. F., Crapo, R. O., Miller, M. R., Jensen, R. L., Falaschetti, E., Schouten, J. P., Hankinson, J. L., et al. (2008) · Thorax · doi:10.1136/thx.2008.098483 · Cited by 535
Cited by
Technology Roadmap for Flexible Sensors
Luo, Y., Abidian, M. R., Ahn, J.-H., Akinwande, D., Andrews, A. M., Antonietti, M., Bao, Z., Berggren, M., Berkey, C. A., Bettinger, C. J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12606 · Cited by 1,383
Self-citationPorous Conductive Textiles for Wearable Electronics
Ding, Y., Jiang, J., Wu, Y., Zhang, Y., Zhou, J., Zhang, Y., Huang, Q., & Zheng, Z. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00507 · Cited by 269
Self-citationTriboelectric nanogenerators as wearable power sources and self-powered sensors
Pu, X., Zhang, C., & Wang, Z. L. (2023) · National Science Review · doi:10.1093/nsr/nwac170 · Cited by 267
Self-citation
Metadata
- Authors
- Ning, C., Cheng, R., Jiang, Y., Sheng, F., Yi, J., Shen, S., Zhang, Y., Peng, X., Dong, K., & Wang, Z. L.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2022-01-31
- Volume
- 16
- Issue
- 2
- Pages
- 2811-2821
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W4210776720
- Cited by
- 279
- References
- 40
- FWCI
- 16.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Helical Fiber Strain Sensors Based on Triboelectric Nanogenerators for Self-Powered Human Respiratory Monitoring. https://app.cochat.ai/papers/10.1021/acsnano.1c09792
- The paper
- Ning, C., Cheng, R., Jiang, Y., Sheng, F., Yi, J., Shen, S., Zhang, Y., Peng, X., Dong, K., & Wang, Z. L. (2022). Helical Fiber Strain Sensors Based on Triboelectric Nanogenerators for Self-Powered Human Respiratory Monitoring. ACS Nano. https://doi.org/10.1021/acsnano.1c09792
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.