The DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.
Stretchable Triboelectric Self‐Powered Sweat Sensor Fabricated from Self‐Healing Nanocellulose Hydrogels
Abstract
Though visualizing perspiration constituents is crucial for physiological evaluation, inadequate material healing and unreliable power supply methods restrict its applications. Herein, a fully flexible self‐powered sweat sensor is fabricated from a cellulose‐based conductive hydrogel to address these issues. The hydrogel electrode is composed of a cellulose nanocomposite polymerized in situ with polyaniline and cross‐linked with polyvinyl alcohol/borax. The cellulose nanocomposites furnish the sweat sensor with tensile and electrical self‐healing efficiencies exceeding 95% within 10 s, a stretchability of 1530%, and conductivity of 0.6 S m−1. The sweat sensor quantitatively analyzes Na+, K+, and Ca 2+ contents in perspiration, to sensitivities of 0.039, 0.082, and 0.069 mmol–1, respectively, in real time via triboelectric effect and wirelessly transmits the results to a user interface. This fabricated sweat sensor with high flexibility, stability, and analytical sensitivity and selectivity provides new opportunities for self‐powered health monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Progress in triboelectric nanogenerators as a new energy technology and self-powered sensors
Wang, Z. L., Chen, J., & Lin, L. (2015) · Energy & Environmental Science · doi:10.1039/c5ee01532d · Cited by 2,174
‘Polyaniline’: Protonic acid doping of the emeraldine form to the metallic regime
Chiang, J.-C., & MacDiarmid, A. G. (1986) · Synthetic Metals · doi:10.1016/0379-6779(86)90070-6 · Cited by 1,979
Yang, J. C., Mun, J., Kwon, S. Y., Park, S., Bao, Z., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201904765 · Cited by 1,641
High-water-content mouldable hydrogels by mixing clay and a dendritic molecular binder
Wang, Q., Mynar, J. L., Yoshida, M., Lee, E., Lee, M., Okuro, K., Kinbara, K., & Aida, T. (2010) · Nature · doi:10.1038/nature08693 · Cited by 1,580
Bariya, M., Nyein, H. Y. Y., & Javey, A. (2018) · Nature Electronics · doi:10.1038/s41928-018-0043-y · Cited by 1,486
Tee, B. C.-K., Wang, C., Allen, R., & Bao, Z. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.192 · Cited by 1,419
Wang, S., & Urban, M. W. (2020) · Nature Reviews Materials · doi:10.1038/s41578-020-0202-4 · Cited by 1,374
Self-citationWearable and flexible electronics for continuous molecular monitoring
Yang, Y., & Gao, W. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00730b · Cited by 1,315
Label‐Free Impedance Biosensors: Opportunities and Challenges
Daniels, J. S., & Pourmand, N. (2007) · Electroanalysis · doi:10.1002/elan.200603855 · Cited by 1,192
Cited by
Device integration of electrochemical biosensors
Wu, J., Liu, H., Chen, W., Ma, B., & Ju, H. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00032-w · Cited by 895
Metadata
- Authors
- Qin, Y., Mo, J., Liu, Y., Zhang, S., Wang, J., Fu, Q., Wang, S., & Nie, S.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2022-03-31
- Volume
- 32
- Issue
- 27
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W4220830837
- Cited by
- 382
- References
- 55
- FWCI
- 22.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Stretchable Triboelectric Self‐Powered Sweat Sensor Fabricated from Self‐Healing Nanocellulose Hydrogels. https://app.cochat.ai/papers/10.1002/adfm.202201846
- The paper
- Qin, Y., Mo, J., Liu, Y., Zhang, S., Wang, J., Fu, Q., Wang, S., & Nie, S. (2022). Stretchable Triboelectric Self‐Powered Sweat Sensor Fabricated from Self‐Healing Nanocellulose Hydrogels. Advanced Functional Materials. https://doi.org/10.1002/adfm.202201846
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.