The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
A Self‐Powered Body Motion Sensing Network Integrated with Multiple Triboelectric Fabrics for Biometric Gait Recognition and Auxiliary Rehabilitation Training
Abstract
Gait analysis provides a convenient strategy for the diagnosis and rehabilitation assessment of diseases of skeletal, muscular, and neurological systems. However, challenges remain in current gait recognition methods due to the drawbacks of complex systems, high cost, affecting natural gait, and one‐size‐fits‐all model. Here, a highly integrated gait recognition system composed of a self‐powered multi‐point body motion sensing network (SMN) based on full textile structure is demonstrated. By combining of newly developed energy harvesting technology of triboelectric nanogenerator (TENG) and traditional textile manufacturing process, SMN not only ensures high pressure response sensitivity up to 1.5 V kPa−1, but also is endowed with several good properties, such as full flexibility, excellent breathability (165 mm s−1), and good moisture permeability (318 g m−2 h−1). By using machine learning to analyze periodic signals and dynamic parameters of limbs swing, the gait recognition system exhibits a high accuracy of 96.7% of five pathological gaits. In addition, a customizable auxiliary rehabilitation exercise system that monitors the extent of the patient's rehabilitation exercise is developed to observe the patient's condition and instruct timely recovery training. The machine learning‐assisted SMN can provide a feasible solution for disease diagnosis and personalized rehabilitation of the patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gait speed and survival in older adults.
Studenski, S. (2011) · JAMA · doi:10.1001/jama.2010.1923 · Cited by 4,558
Choi, S., Han, S. I., Jung, D., Hwang, H. J., Lim, C., Bae, S., Park, O. K., Tschabrunn, C. M., Lee, M., Bae, S. Y., et al. (2018) · Nature Nanotechnology · doi:10.1038/s41565-018-0226-8 · Cited by 984
Smart textile triboelectric nanogenerators: Current status and perspectives
Dong, K., Hu, Y., Yang, J., Kim, S.-W., Hu, W., & Wang, Z. L. (2021) · MRS Bulletin · doi:10.1557/s43577-021-00123-2 · Cited by 154
Self-citation
Cited by
Porous Conductive Textiles for Wearable Electronics
Ding, Y., Jiang, J., Wu, Y., Zhang, Y., Zhou, J., Zhang, Y., Huang, Q., & Zheng, Z. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00507 · Cited by 269
Fiber/Yarn and Textile-Based Piezoresistive Pressure Sensors
Yang, Y., Liu, Y., & Yin, R. (2025) · Advanced Fiber Materials · doi:10.1007/s42765-024-00479-5 · Cited by 110
Metadata
- Authors
- Wei, C., Cheng, R., Ning, C., Wei, X., Peng, X., Lv, T., Sheng, F., Dong, K., & Wang, Z. L.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2023-05-07
- Volume
- 33
- Issue
- 35
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W4375843245
- Cited by
- 190
- References
- 3
- FWCI
- 13.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Self‐Powered Body Motion Sensing Network Integrated with Multiple Triboelectric Fabrics for Biometric Gait Recognition and Auxiliary Rehabilitation Training. https://app.cochat.ai/papers/10.1002/adfm.202303562
- The paper
- Wei, C., Cheng, R., Ning, C., Wei, X., Peng, X., Lv, T., Sheng, F., Dong, K., & Wang, Z. L. (2023). A Self‐Powered Body Motion Sensing Network Integrated with Multiple Triboelectric Fabrics for Biometric Gait Recognition and Auxiliary Rehabilitation Training. Advanced Functional Materials. https://doi.org/10.1002/adfm.202303562
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.