CoChat

Highly conductive, stretchable and biocompatible Ag–Au core–sheath nanowire composite for wearable and implantable bioelectronics

Choi, Suji, Han, Sang Ihn, Jung, Dongjun, Hwang, Hye Jin, Lim, Chaehong, Bae, Soochan, Park, Ok Kyu, Tschabrunn, Cory M., Lee, Mincheol, Bae, Sun Youn, Yu, Ji Woong, Ryu, Ji Ho, Lee, Sang-Woo, Park, Kyungpyo, Kang, Peter M., Lee, Won Bo, Nezafat, Reza, Hyeon, Taeghwan, Kim, Dae-Hyeong · 2018 · Nature Nanotechnology

The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.

Abstract

Wearable and implantable devices require conductive, stretchable and biocompatible materials. However, obtaining composites that simultaneously fulfil these requirements is challenging due to a trade-off between conductivity and stretchability. Here, we report on Ag-Au nanocomposites composed of ultralong gold-coated silver nanowires in an elastomeric block-copolymer matrix. Owing to the high aspect ratio and percolation network of the Ag-Au nanowires, the nanocomposites exhibit an optimized conductivity of 41,850 S cm -1 (maximum of 72,600 S cm -1 ). Phase separation in the Ag-Au nanocomposite during the solvent-drying process generates a microstructure that yields an optimized stretchability of 266% (maximum of 840%). The thick gold sheath deposited on the silver nanowire surface prevents oxidation and silver ion leaching, making the composite biocompatible and highly conductive. Using the nanocomposite, we successfully fabricate wearable and implantable soft bioelectronic devices that can be conformally integrated with human skin and swine heart for continuous electrophysiological recording, and electrical and thermal stimulation.

Overview

Integrity signals

Registry

Crossref · 10.1038/s41565-018-0226-8

Cites

40 of 40 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 40 references

Cited by

See all 1,000

Metadata

Authors
Choi, S., Han, S. I., Jung, D., Hwang, H. J., Lim, C., Bae, S., Park, O. K., Tschabrunn, C. M., Lee, M., Bae, S. Y., Yu, J. W., Ryu, J. H., Lee, S.-W., Park, K., Kang, P. M., Lee, W. B., Nezafat, R., Hyeon, T., & Kim, D.-H.
Affiliations
  • Seoul National University (KR)
  • Beth Israel Deaconess Medical Center (US)
Corresponding author
  • Hyeon, Taeghwan
  • Kim, Dae-Hyeong
Venue
Nature Nanotechnology
Published
2018-08-13
Volume
13
Issue
11
Pages
1048-1056
ISSN
  • 1748-3387 (ISSN-L)
  • 1748-3395
OpenAlex
W2886878416
Cited by
984
References
40
Citations by year
2026: 56 · 2025: 109 · 2024: 140 · 2023: 161 · 2022: 137 · 2021: 152 · 2020: 118 · 2019: 100 · 2018: 10
FWCI
36.31
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • Nature Nanotechnology (publishedVersion)
  • PubMed (publishedVersion)
  • Digital Access to Scholarship at Harvard (DASH) (Harvard University) (acceptedVersion)
  • Seoul National University Open Repository (Seoul National University) (submittedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
Keywords
stretchable conductors, percolation network, phase separation, biocompatibility, wearable bioelectronics, implantable bioelectronics, electrophysiological recording, cardiac stimulation, thermal stimulation, soft electronics

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Highly conductive, stretchable and biocompatible Ag–Au core–sheath nanowire composite for wearable and implantable bioelectronics. https://app.cochat.ai/papers/10.1038/s41565-018-0226-8
The paper
Choi, S., Han, S. I., Jung, D., Hwang, H. J., Lim, C., Bae, S., Park, O. K., Tschabrunn, C. M., Lee, M., Bae, S. Y., Yu, J. W., Ryu, J. H., Lee, S.-W., Park, K., Kang, P. M., Lee, W. B., Nezafat, R., Hyeon, T., & Kim, D.-H. (2018). Highly conductive, stretchable and biocompatible Ag–Au core–sheath nanowire composite for wearable and implantable bioelectronics. Nature Nanotechnology. https://doi.org/10.1038/s41565-018-0226-8

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.