The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Microneedle‐Based Transdermal Sensor for On‐Chip Potentiometric Determination of K+
Abstract
The determination of electrolytes is invaluable for point of care diagnostic applications. An ion selective transdermal microneedle sensor is demonstrated for potassium by integrating a hollow microneedle with a microfluidic chip to extract fluid through a channel towards a downstream solid‐state ion‐selective‐electrode (ISE). 3D porous carbon and 3D porous graphene electrodes, made via interference lithography, are compared as solid‐state transducers for ISE's and evaluated for electrochemical performance, stability, and selectivity. The porous carbon K+ ISE's show better performance than the porous graphene K+ ISE's, capable of measuring potassium across normal physiological concentrations in the presence of interfering ions with greater stability. This new microfluidic/microneedle platform shows promise for medical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
Cited by
3D-printing technologies for electrochemical applications
Ambrosi, A., & Pumera, M. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00714c · Cited by 1,040
Rational design of all-solid-state ion-selective electrodes and reference electrodes
Hu, J., Stein, A., & Bühlmann, P. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.11.004 · Cited by 586
Shao, Y., Ying, Y., & Ping, J. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00587k · Cited by 472
Chang, H., Zheng, M., Yu, X., Than, A., Seeni, R. Z., Kang, R., Tian, J., Khanh, D. P., Liu, L., Chen, P., et al. (2017) · Advanced Materials · doi:10.1002/adma.201702243 · Cited by 462
Broza, Y. Y., Zhou, X., Yuan, M., Qu, D., Zheng, Y., Vishinkin, R., Khatib, M., Wu, W., & Haick, H. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00437 · Cited by 461
Metadata
- Authors
- Miller, P. R., Xiao, X., Brener, I., Burckel, D. B., Narayan, R., & Polsky, R.
- Venue
- Advanced Healthcare Materials
- Publisher
- Wiley
- Published
- 2013-12-21
- Volume
- 3
- Issue
- 6
- Pages
- 876-881
- ISSN
- 2192-2640 (ISSN-L)
- 2192-2659
- OpenAlex
- W2054162828
- Cited by
- 161
- References
- 2
- FWCI
- 4.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microneedle‐Based Transdermal Sensor for On‐Chip Potentiometric Determination of K+. https://app.cochat.ai/papers/10.1002/adhm.201300541
- The paper
- Miller, P. R., Xiao, X., Brener, I., Burckel, D. B., Narayan, R., & Polsky, R. (2014). Microneedle‐Based Transdermal Sensor for On‐Chip Potentiometric Determination of K+. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.201300541
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.