The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Organic Electrochemical Transistors for Clinical Applications
Abstract
The ability of organic electrochemical transistors is explored to record human electrophysiological signals of clinical relevance. An organic electrochemical transistor (OECT) that shows a high (>1 mS) transconductance at zero applied gate voltage is used, necessitating only one power supply to bias the drain, while the gate circuit is driven by cutaneous electrical potentials. The OECT is successful in recording cardiac rhythm, eye movement, and brain activity of a human volunteer. These results pave the way for applications of OECTs as an amplifying transducer for human electrophysiology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Buzsáki, G. (2006) · doi:10.1093/acprof:oso/9780195301069.001.0001 · Cited by 4,873
Subjective and objective sleepiness in the active individual
Åkerstedt, T., & Gillberg, M. (1990) · International Journal of Neuroscience · doi:10.3109/00207459008994241 · Cited by 3,088
An ultra-lightweight design for imperceptible plastic electronics
Kaltenbrunner, M., Sekitani, T., Reeder, J., Yokota, T., Kuribara, K., Tokuhara, T., Drack, M., Schwödiauer, R., Graz, I., Bauer-Gogonea, S., et al. (2013) · Nature · doi:10.1038/nature12314 · Cited by 2,485
Pfurtscheller, G., Stancák, A., & Neuper, C. (1996) · International Journal of Psychophysiology · doi:10.1016/s0167-8760(96)00066-9 · Cited by 1,205
Cited by
Organic electrochemical transistors
Rivnay, J., Inal, S., Salleo, A., Owens, R. M., Berggren, M., & Malliaras, G. G. (2018) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.86 · Cited by 2,065
Self-citationRoot, S. E., Savagatrup, S., Printz, A. D., Rodriquez, D., & Lipomi, D. J. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00003 · Cited by 904
High-performance transistors for bioelectronics through tuning of channel thickness
Rivnay, J., Leleux, P., Ferro, M., Sessolo, M., Williamson, A., Koutsouras, D. A., Khodagholy, D., Ramuz, M., Strakosas, X., Owens, R. M., et al. (2015) · Science Advances · doi:10.1126/sciadv.1400251 · Cited by 728
Self-citationMaterials and Structures toward Soft Electronics
Wang, C., Wang, C., Huang, Z., & Xu, S. (2018) · Advanced Materials · doi:10.1002/adma.201801368 · Cited by 662
Parlak, O., Keene, S. T., Marais, A., Curto, V. F., & Salleo, A. (2018) · Science Advances · doi:10.1126/sciadv.aar2904 · Cited by 603
Metadata
- Authors
- Leleux, P., Rivnay, J., Lonjaret, T., Badier, J., Bénar, C., Hervé, T., Chauvel, P., & Malliaras, G. G.
- Venue
- Advanced Healthcare Materials
- Publisher
- Wiley
- Published
- 2014-09-29
- Volume
- 4
- Issue
- 1
- Pages
- 142-147
- ISSN
- 2192-2640 (ISSN-L)
- 2192-2659
- OpenAlex
- W2044688936
- Cited by
- 163
- References
- 5
- FWCI
- 5.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Organic Electrochemical Transistors for Clinical Applications. https://app.cochat.ai/papers/10.1002/adhm.201400356
- The paper
- Leleux, P., Rivnay, J., Lonjaret, T., Badier, J., Bénar, C., Hervé, T., Chauvel, P., & Malliaras, G. G. (2015). Organic Electrochemical Transistors for Clinical Applications. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.201400356
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.