Interpenetrating Conducting Hydrogel Materials for Neural Interfacing Electrodes
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Conducting hydrogels (CHs) are an emerging technology in the field of medical electrodes and brain–machine interfaces. The greatest challenge to the fabrication of CH electrodes is the hybridization of dissimilar polymers (conductive polymer and hydrogel) to ensure the formation of interpenetrating polymer networks (IPN) required to achieve both soft and electroactive materials. A new hydrogel system is developed that enables tailored placement of covalently immobilized dopant groups within the hydrogel matrix. The role of immobilized dopant in the formation of CH is investigated through covalent linking of sulfonate doping groups to poly(vinyl alcohol) (PVA) macromers. These groups control the electrochemical growth of the conducting polymer poly(3,4‐ethylenedioxythiophene) (PEDOT) and subsequent material properties. The effect of dopant density and interdopant spacing on the physical, electrochemical, and mechanical properties of the resultant CHs is examined. Cytocompatible PVA hydrogels with PEDOT penetration throughout the depth of the electrode are produced. Interdopant spacing is found to be the key factor in the formation of IPNs, with smaller interdopant spacing producing CH electrodes with greater charge storage capacity and lower impedance due to increased PEDOT growth throughout the network. This approach facilitates tailorable, high‐performance CH electrodes for next generation, low impedance neuroprosthetic devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Hierarchical nanostructured conducting polymer hydrogel with high electrochemical activity
Pan, L., Yu, G., Zhai, D., Lee, H. R., Zhao, W., Liu, N., Wang, H., Tee, B. C.-K., Shi, Y., Cui, Y., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1202636109 · Cited by 1,216
Green, R. A., Lovell, N. H., & Poole-Warren, L. A. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.06.030 · Cited by 170
Self-citationNon-affine deformations in polymer hydrogels
Wen, Q., Basu, A., Janmey, P. A., & Yodh, A. G. (2012) · Soft Matter · doi:10.1039/c2sm25364j · Cited by 148
Stiffness quantification of conductive polymers for bioelectrodes
Hassarati, R. T., Goding, J. A., Baek, S., Patton, A. J., Poole‐Warren, L. A., & Green, R. A. (2014) · Journal of Polymer Science Part B Polymer Physics · doi:10.1002/polb.23465 · Cited by 35
Self-citation
Cited by
Yuk, H., Lu, B., & Zhao, X. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00595h · Cited by 2,108
Stretchable Conductive Polymers and Composites Based on PEDOT and PEDOT:PSS
Kayser, L. V., & Lipomi, D. J. (2019) · Advanced Materials · doi:10.1002/adma.201806133 · Cited by 1,186
Lu, B., Yuk, H., Lin, S., Jian, N., Qu, K., Xu, J., & Zhao, X. (2019) · Nature Communications · doi:10.1038/s41467-019-09003-5 · Cited by 1,035
Soft and elastic hydrogel-based microelectronics for localized low-voltage neuromodulation
Liu, Y., Liu, J., Chen, S., Lei, T., Kim, Y., Niu, S., Wang, H., Wang, X., Foudeh, A. M., Tok, J. B.-H., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0335-6 · Cited by 811
Recent advances in conductive hydrogels: classifications, properties, and applications
Zhu, T., Ni, Y., Biesold, G. M., Cheng, Y., Ge, M., Li, H., Huang, J., Lin, Z., & Lai, Y. (2023) · Chemical Society Reviews · doi:10.1039/d2cs00173j · Cited by 738
Metadata
- Authors
- Goding, J., Gilmour, A., Martens, P., Poole‐Warren, L., & Green, R.
- Venue
- Advanced Healthcare Materials
- Publisher
- Wiley
- Published
- 2017-02-15
- Volume
- 6
- Issue
- 9
- ISSN
- 2192-2640 (ISSN-L)
- 2192-2659
- OpenAlex
- W2588722509
- Cited by
- 110
- References
- 5
- FWCI
- 7.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.