Stiffness quantification of conductive polymers for bioelectrodes
Abstract
ABSTRACT Conductive polymer (CP) coatings can improve the performance of metallic bioelectrodes in implantable devices, a benefit which is partially attributed to the “softer” material interface. However, due to the nature of CP fabrication on metallic substrates, accurate quantification of mechanical properties has been difficult to achieve. This study demonstrates that peak‐force quantitative nanomechanical mapping (PF‐QNM) is a robust technique for determining the modulus of CP coatings. The effect of dopant size, chemistry, and film hydration on the mechanical properties of poly(3,4‐ethylene dioxythiophene) (PEDOT) is also examined. Analysis of PEDOT doped with poly(styrene sulfonate) produced across five different thicknesses confirms the utility of PF‐QNM in yielding quantitative, repeatable moduli in both the dry and hydrated state. By doping PEDOT with paratoluene sulfonate and perchlorate (ClO4) it is shown that the hydrophilicity and the size of the dopant are both critical factors influencing CP mechanical properties in the hydrated environment. © 2014 Wiley Periodicals, Inc. J. Polym. Sci., Part B: Polym. Phys.2014,52, 666–675
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Conductive polymers are considerably softer than metals, flexible and conformable, and have a high charge injection capacity.
“Conductive polymers have been widely used in implantable devices for research as they are considerably softer than metals, flexible and conformable, and have a high charge injection capacity [166][167][168][169][170].”
From Advances in visual prostheses: engineering and biological challenges (2022) · cites this paper as [166]
Cites
Effect of contact deformations on the adhesion of particles
Derjaguin, B. V., Muller, V. M., & Toporov, Y. P. (1975) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(75)90018-1 · Cited by 4,618 · see citing works
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896 · see citing works
A buckling-based metrology for measuring the elastic moduli of polymeric thin films
Stafford, C. M., Harrison, C. K., Beers, K. L., Karim, A., Amis, E. J., VanLandingham, M. R., Kim, H., Volksen, W., Miller, R. D., & Simonyi, E. E. (2004) · Nature Materials · doi:10.1038/nmat1175 · Cited by 1,369 · see citing works
Conducting polymers for neural interfaces: Challenges in developing an effective long-term implant
Green, R. A., Lovell, N. H., Wallace, G. G., & Poole-Warren, L. A. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.047 · Cited by 691 · see citing works
Self-citationElectrical properties of implant encapsulation tissue
Grill, W. M., & Mortimer, J. T. (1994) · Annals of Biomedical Engineering · doi:10.1007/bf02368219 · Cited by 376 · see citing works
Mechanical characterization of PEDOT:PSS thin films
Lang, U., Naujoks, N., & Dual, J. (2008) · Synthetic Metals · doi:10.1016/j.synthmet.2008.11.005 · Cited by 369 · see citing works
Cui, X. T., Hetke, J. F., Wiler, J. A., Anderson, D. J., & Martin, D. C. (2001) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(01)00637-9 · Cited by 331 · see citing works
A review of analysis methods for sub-micron indentation testing
Fischer-Cripps, A. C. (2000) · Vacuum · doi:10.1016/s0042-207x(00)00377-8 · Cited by 319 · see citing works
Cell attachment functionality of bioactive conducting polymers for neural interfaces
Green, R. A., Lovell, N. H., & Poole-Warren, L. A. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.03.043 · Cited by 258 · see citing works
Self-citationSubstrate dependent stability of conducting polymer coatings on medical electrodes
Green, R. A., Hassarati, R. T., Bouchinet, L., Lee, C. S., Cheong, G. L. M., Yu, J., Dodds, C. W. D., Suaning, G. J., Poole-Warren, L. A., & Lovell, N. H. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.05.017 · Cited by 207 · see citing works
Self-citationThe Morphology of Poly(3,4-Ethylenedioxythiophene)
Martin, D. C., Wu, J., Shaw, C. M., et al. (2010) · Journal of macromolecular science. Part C, Reviews in macromolecular chemistry and physics/Journal of macromolecular science. Reviews in macromolecular chemistry and physics · doi:10.1080/15583724.2010.495440 · Cited by 183 · see citing works
Age-Dependent Regional Mechanical Properties of the Rat Hippocampus and Cortex
Elkin, B. S., Ilankovan, A., & Morrison, B. (2009) · Journal of Biomechanical Engineering · doi:10.1115/1.4000164 · Cited by 166 · see citing works
Tallman, D. E., Vang, C. K., Wallace, G. G., et al. (2002) · Journal of The Electrochemical Society · doi:10.1149/1.1448820 · Cited by 140 · see citing works
Performance of conducting polymer electrodes for stimulating neuroprosthetics
Green, R. A., Matteucci, P. B., Hassarati, R. T., Giraud, B., Dodds, C. W. D., Chen, S., Byrnes-Preston, P., Suaning, G. J., Poole-Warren, L. A., & Lovell, N. H. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/1/016009 · Cited by 127 · see citing works
Self-citationConducting polymer aerogels from supercritical CO2 drying PEDOT-PSS hydrogels
Zhang, X., Chang, D., Liu, J., & Luo, Y. (2010) · Journal of Materials Chemistry · doi:10.1039/c0jm00050g · Cited by 125 · see citing works
Atomic Force Microscopy: General Principles and a New Implementation
McClelland, G. M., Erlandsson, R., & Chiang, S. (1987) · Review of Progress in Quantitative Nondestructive Evaluation · doi:10.1007/978-1-4613-1893-4_148 · Cited by 100 · see citing works
Spanninga, S. A., Martin, D. C., & Chen, Z. (2009) · The Journal of Physical Chemistry C · doi:10.1021/jp811282f · Cited by 95 · see citing works
Wang, X., Tang, H.-P., Li, X., & Hua, X. (2009) · International Journal of Molecular Sciences · doi:10.3390/ijms10125257 · Cited by 72 · see citing works
Yang, J., & Martin, D. C. (2006) · Journal of materials research/Pratt's guide to venture capital sources · doi:10.1557/jmr.2006.0145 · Cited by 63 · see citing works
Ariza, M. J., Benavente, J., Rodrı́guez-Castellón, E., et al. (2002) · Journal of Colloid and Interface Science · doi:10.1006/jcis.2001.8071 · Cited by 55 · see citing works
High Temperature Mechanical Properties of the Platinum Group Metals
Fischer, B. M., Behrends, A., Freund, D., et al. (1999) · Platinum Metals Review · doi:10.1595/003214099x4311828 · Cited by 52 · see citing works
Challenges and Progress in High‐Throughput Screening of Polymer Mechanical Properties by Indentation
Kranenburg, J. M., Tweedie, C. A., Vliet, K. J. V., & Schubert, U. S. (2009) · Advanced Materials · doi:10.1002/adma.200803538 · Cited by 47 · see citing works
Modelling encapsulation tissue around cochlear implant electrodes
Hanekom, T. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345122 · Cited by 42 · see citing works
Fischer, B. M., Behrends, A., Freund, D., et al. (1999) · Platinum Metals Review · Cited by 33 · see citing works
Thin film hydrophilic electroactive polymer coatings for bioelectrodes
Baek, S., Green, R. A., Granville, A. M., et al. (2013) · Journal of Materials Chemistry B · doi:10.1039/c3tb20152j · Cited by 30 · see citing works
Self-citationState-of-the-Art of Thermo-Mechanical Characterization of Thin Polymer Films
Jansen, K. M. B., Gonda, V., Ernst, L. J., et al. (2004) · Journal of Electronic Packaging · doi:10.1115/1.2070092 · Cited by 14 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Sasaki, M., Karikkineth, B. C., Nagamine, K., Kaji, H., Torimitsu, K., & Nishizawa, M. (2014) · Advanced Healthcare Materials · doi:10.1002/adhm.201400209 · Cited by 169 · see citing works
Flexible and highly biocompatible nanofiber-based electrodes for neural surface interfacing
Heo, D. N., Kim, H.-J., Lee, Y. J., Heo, M., Lee, S. J., Lee, D., Do, S. H., Lee, S. H., & Kwon, I. K. (2017) · ACS Nano · doi:10.1021/acsnano.6b08390 · Cited by 86 · see citing works
Visual prosthesis: interfacing stimulating electrodes with retinal neurons to restore vision.
Barriga-Rivera, A., Bareket, L., Goding, J., Aregueta-Robles, U. A., & Suaning, G. J. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00620 · Cited by 73 · see citing works
Self-citationAdvances in visual prostheses: engineering and biological challenges
Borda, E., & Ghezzi, D. (2022) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ac812c · Cited by 44 · see citing works
- Authors
- Hassarati, R. T., Goding, J. A., Baek, S., Patton, A. J., Poole‐Warren, L. A., & Green, R. A.
- Affiliations
- UNSW Sydney (AU)
- Graduate School of Biomedical Engineering University of New South Wales Sydney 2052 New South Wales Australia
- Corresponding author
- Green, Rylie A.
- Venue
- Journal of Polymer Science Part B Polymer Physics
- Publisher
- Wiley
- Published
- 2014-02-26
- Volume
- 52
- Issue
- 9
- Pages
- 666-675
- ISSN
- 0887-6266 (ISSN-L)
- 1099-0488
- OpenAlex
- W2159688165
- Cited by
- 35
- References
- 26
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 3 · 2023: 4 · 2022: 2 · 2021: 1 · 2020: 2 · 2019: 4 · 2018: 2 · 2017: 5 · 2016: 2 · 2015: 6 · 2014: 1
- FWCI
- 3.26
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Polymer Science Part B Polymer Physics (publishedVersion)
- Topics
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Force Microscopy Techniques and Applications
- Keywords
- conducting polymers, bioelectrodes, PEDOT, polystyrene sulfonate, perchlorate doping, elastic modulus, film hydration, hydrophilicity, biomedical implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review