A Physicochemically Optimized and Neuroconductive Biphasic Nerve Guidance Conduit for Peripheral Nerve Repair
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Clinically available hollow nerve guidance conduits (NGCs) have had limited success in treating large peripheral nerve injuries. This study aims to develop a biphasic NGC combining a physicochemically optimized collagen outer conduit to bridge the transected nerve, and a neuroconductive hyaluronic acid‐based luminal filler to support regeneration. The outer conduit is mechanically optimized by manipulating crosslinking and collagen density, allowing the engineering of a high wall permeability to mitigate the risk of neuroma formation, while also maintaining physiologically relevant stiffness and enzymatic degradation tuned to coincide with regeneration rates. Freeze‐drying is used to seamlessly integrate the luminal filler into the conduit, creating a longitudinally aligned pore microarchitecture. The luminal stiffness is modulated to support Schwann cells, with laminin incorporation further enhancing bioactivity by improving cell attachment and metabolic activity. Additionally, this biphasic NGC is shown to support neurogenesis and gliogenesis of neural progenitor cells and axonal outgrowth from dorsal root ganglia. These findings highlight the paradigm that a successful NGC requires the concerted optimization of both a mechanical support phase capable of bridging a nerve defect and a neuroconductive phase with an architecture capable of supporting both Schwann cells and neurons in order to achieve functional regenerative outcome.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Matrix stiffness-induced myofibroblast differentiation is mediated by intrinsic mechanotransduction
Huang, X., Yang, N., Fiore, V. F., Barker, T. H., Sun, Y., Morris, S. W., Ding, Q., Thannickal, V. J., & Zhou, Y. (2012) · American Journal of Respiratory Cell and Molecular Biology · doi:10.1165/rcmb.2012-0050oc · Cited by 530
Mechanical properties of acellular peripheral nerve
Borschel, G. H., Kia, K. F., Kuzon, W. M., & Dennis, R. G. (2003) · Journal of Surgical Research · doi:10.1016/s0022-4804(03)00255-5 · Cited by 284
The influence of substrate stiffness on the behavior and functions of Schwann cells in culture
Gu, Y., Ji, Y., Zhao, Y., Liu, Y., Ding, F., Gu, X., & Yang, Y. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.06.006 · Cited by 162
Cited by
Novel Biomedical Applications of Crosslinked Collagen
Gu, L., Shan, T., Ma, Y.-X., Tay, F. R., & Niu, L. (2019) · Trends in Biotechnology · doi:10.1016/j.tibtech.2018.10.007 · Cited by 305
Modern Trends for Peripheral Nerve Repair and Regeneration: Beyond the Hollow Nerve Guidance Conduit
Carvalho, C. R., Oliveira, J. M., & Reis, R. L. (2019) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00337 · Cited by 297
Yang, C.-Y., Huang, W.-Y., Chen, L.-H., Liang, N.-W., Wang, H.-C., Lu, J., Wang, X., & Wang, T.-W. (2021) · Journal of Materials Chemistry B · doi:10.1039/d0tb01605e · Cited by 161
Metadata
- Authors
- Ryan, A. J., Lackington, W. A., Hibbitts, A. J., Matheson, A., Alekseeva, T., Stejskalova, A., Roche, P., & O'Brien, F. J.
- Venue
- Advanced Healthcare Materials
- Publisher
- Wiley
- Published
- 2017-10-04
- Volume
- 6
- Issue
- 24
- ISSN
- 2192-2640 (ISSN-L)
- 2192-2659
- OpenAlex
- W2763409755
- Cited by
- 67
- References
- 3
- FWCI
- 2.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.