A Capsule‐Type Microrobot with Pick‐and‐Drop Motion for Targeted Drug and Cell Delivery
The DOI matches its Crossref record.
Abstract
A capsule‐type microrobot exhibits “pick‐and‐drop” (P&D) motion to hold a particle within a confined volume and transports it via a corkscrewing motion. The P&D motion is possible because the capsule‐type microrobot has two parts: a plunger and a cap. The fabricated microrobots are wirelessly controlled by a magnetic manipulator. Drugs or cells can be encapsulated in the container of the capsule‐type microrobot by the P&D motion or attached to the surface of the cap, which can be used as a supporting structure. Therefore, the capsule‐type microrobot can deliver suspended or adherent cells. The drug or cells are minimally exposed or not completely exposed to the surrounding fluid and do not experience shear force when encapsulated in the container. As a proof‐of‐concept, secure transportation of microparticles in the confined volume of the capsule via P&D motion is demonstrated. In addition, the cap is used as a scaffold for neuronal cell culture on a rat brain slice to demonstrate its biocompatibility and feasibility for targeted cell delivery. The proposed capsule‐type microrobot is suitable for diverse applications, as it protects the encapsulated materials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Medical Micro/Nanorobots in Precision Medicine
Soto, F., Wang, J., Ahmed, R., & Demirci, U. (2020) · Advanced Science · doi:10.1002/advs.202002203 · Cited by 442
Magnetically actuated microrobots as a platform for stem cell transplantation
Jeon, S., Kim, S., Ha, S., Lee, S., Kim, E., Kim, S. Y., Park, S. H., Jeon, J. H., Kim, S. W., Moon, C., et al. (2019) · Science Robotics · doi:10.1126/scirobotics.aav4317 · Cited by 412
“A capsule-type microrobot is capable of performing pick-upand-dropmotions to deliver olfactory receptor neuron cells adherent to the scaffold-type cap of the microrobot on a rat brain slice (37).”
BackgroundSelf-citationSpiegel, C. A., Hippler, M., Münchinger, A., Bastmeyer, M., Barner‐Kowollik, C., Wegener, M., & Blasco, E. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201907615 · Cited by 215
Park, J., Jin, C., Lee, S., Kim, J., & Choi, H. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201900213 · Cited by 201
Self-citationTranslational prospects of untethered medical microrobots
Ceylan, H., Yasa, I. C., Kilic, U., Hu, W., & Sitti, M. (2019) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ab22d5 · Cited by 188
Metadata
- Authors
- Lee, S., Kim, S., Kim, S., Kim, J., Moon, C., Nelson, B. J., & Choi, H.
- Venue
- Advanced Healthcare Materials
- Publisher
- Wiley
- Published
- 2018-02-20
- Volume
- 7
- Issue
- 9
- Pages
- e1700985-e1700985
- ISSN
- 2192-2640 (ISSN-L)
- 2192-2659
- OpenAlex
- W2792004436
- Cited by
- 125
- References
- 0
- FWCI
- 8.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Capsule‐Type Microrobot with Pick‐and‐Drop Motion for Targeted Drug and Cell Delivery. https://app.cochat.ai/papers/10.1002/adhm.201700985
- The paper
- Lee, S., Kim, S., Kim, S., Kim, J., Moon, C., Nelson, B. J., & Choi, H. (2018). A Capsule‐Type Microrobot with Pick‐and‐Drop Motion for Targeted Drug and Cell Delivery. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.201700985
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.