The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Magnetically Actuated Degradable Microrobots for Actively Controlled Drug Release and Hyperthermia Therapy
Abstract
Microrobots facilitate targeted therapy due to their small size, minimal invasiveness, and precise wireless control. A degradable hyperthermia microrobot (DHM) with a 3D helical structure is developed, enabling actively controlled drug delivery, release, and hyperthermia therapy. The microrobot is made of poly(ethylene glycol) diacrylate (PEGDA) and pentaerythritol triacrylate (PETA) and contains magnetic Fe 3 O 4 nanoparticles (MNPs) and 5‐fluorouracil (5‐FU). Its locomotion is remotely and precisely controlled by a rotating magnetic field (RMF) generated by an electromagnetic actuation system. Drug‐free DHMs reduce the viability of cancer cells by elevating the temperature under an alternating magnetic field (AMF), a hyperthermic effect. 5‐FU is released from the proposed DHMs in normal‐, high‐burst‐, and constant‐release modes, controlled by the AMF. Finally, actively controlled drug release from the DHMs in normal‐ and high‐burst‐release mode results in a reduction in cell viability. The reduction in cell viability is of greater magnitude in high‐burst‐ than in normal‐release mode. In summary, biodegradable DHMs have potential for actively controlled drug release and hyperthermia therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Drug Delivery Systems: Entering the Mainstream
Allen, T. M., & Cullis, P. R. (2004) · Science · doi:10.1126/science.1095833 · Cited by 4,552
Purcell, E. M. (1977) · American Journal of Physics · doi:10.1119/1.10903 · Cited by 4,360
Poly(ethylene glycol) in Drug Delivery: Pros and Cons as Well as Potential Alternatives
Knop, K., Hoogenboom, R., Fischer, D., & Schubert, U. S. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200902672 · Cited by 3,533
Kamaly, N., Yameen, B., Wu, J., & Farokhzad, O. C. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00346 · Cited by 3,070
Polymeric systems for controlled drug release
Uhrich, K. E., Cannizzaro, S. M., Langer, R. S., & Shakesheff, K. M. (1999) · Chemical Reviews · doi:10.1021/cr940351u · Cited by 2,633
Langer, R. (1990) · Science · doi:10.1126/science.2218494 · Cited by 1,778
Bio-inspired magnetic swimming microrobots for biomedical applications
Peyer, K. E., Zhang, L., & Nelson, B. J. (2013) · Nanoscale · doi:10.1039/c2nr32554c · Cited by 820
Phase inversion dynamics of PLGA solutions related to drug delivery
Graham, P. D., Brodbeck, K. J., & McHugh, A. J. (1999) · Journal of Controlled Release · doi:10.1016/s0168-3659(98)00158-8 · Cited by 222
HE, G., MA, L., PAN, J., & VENKATRAMAN, S. (2007) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2006.10.020 · Cited by 123
Cited by
3D printing of functional microrobots
Li, J., & Pumera, M. (2021) · Chemical Society Reviews · doi:10.1039/d0cs01062f · Cited by 303
Metadata
- Authors
- Park, J., Jin, C., Lee, S., Kim, J., & Choi, H.
- Venue
- Advanced Healthcare Materials
- Publisher
- Wiley
- Published
- 2019-07-10
- Volume
- 8
- Issue
- 16
- Pages
- e1900213-e1900213
- ISSN
- 2192-2640 (ISSN-L)
- 2192-2659
- OpenAlex
- W2960639179
- Cited by
- 201
- References
- 9
- FWCI
- 11.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetically Actuated Degradable Microrobots for Actively Controlled Drug Release and Hyperthermia Therapy. https://app.cochat.ai/papers/10.1002/adhm.201900213
- The paper
- Park, J., Jin, C., Lee, S., Kim, J., & Choi, H. (2019). Magnetically Actuated Degradable Microrobots for Actively Controlled Drug Release and Hyperthermia Therapy. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.201900213
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.