The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Translational prospects of untethered medical microrobots
Open accessAbstract
Untethered mobile microrobots have the potential to transform medicine radically. Their small size and wireless mobility can enable access to and navigation in confined, small, hard-to-reach, and sensitive inner body sites, where they can provide new ways of minimally invasive interventions and targeted diagnosis and therapy down to the cellular length scales with high precision and repeatability. The exponential recent progress of the field at the preclinical level raises anticipations for their near-future clinical prospects. To pave the way for this transformation to happen, however, the formerly proposed microrobotic system designs need a comprehensive review by including essential aspects that a microrobot needs to function properly and safely in given in vivo conditions of a targeted medical problem. The present review provides a translational perspective on medical microrobotics research with an application-oriented, integrative design approach. The blueprint of a medical microrobot needs to take account of microrobot shape, material composition, manufacturing technique, permeation of biological barriers, deployment strategy, actuation and control methods, medical imaging modality, and the execution of the prescribed medical tasks altogether at the same time. The incorporation of functional information pertaining each such element to the physical design of the microrobot is highly dependent on the specific clinical application scenario. We discuss the complexity of the challenges ahead and the potential directions to overcome them. We also throw light on the potential regulatory aspects of medical microrobots toward their bench-to-bedside translation. Such a multifaceted undertaking entails multidisciplinary involvement of engineers, materials scientists, biologists and medical doctors, and bringing their focus on specific medical problems where microrobots could make a disruptive or radical impact.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Purcell, E. M. (1977) · American Journal of Physics · doi:10.1119/1.10903 · Cited by 4,360
Biomedical applications of biodegradable polymers
Ulery, B. D., Nair, L. S., & Laurencin, C. T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22259 · Cited by 2,206
Biomedical applications of soft robotics
Cianchetti, M., Laschi, C., Menciassi, A., & Dario, P. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0022-y · Cited by 1,435
Reconfigurable magnetic microrobot swarm: Multimode transformation, locomotion, and manipulation
Xie, H., Sun, M., Fan, X., Lin, Z., Chen, W., Wang, L., Dong, L., & He, Q. (2019) · Science Robotics · doi:10.1126/scirobotics.aav8006 · Cited by 772
A Decade of the Protein Corona
Ke, P. C., Lin, S., Parak, W. J., Davis, T. P., & Caruso, F. (2017) · ACS Nano · doi:10.1021/acsnano.7b08008 · Cited by 672
Bioinspired Helical Microswimmers Based on Vascular Plants
Gao, W., Feng, X., Pei, A., Kane, C. R., Tam, R., Hennessy, C., & Wang, J. (2014) · Nano Letters · doi:10.1021/nl404044d · Cited by 380
Hadjidemetriou, M., Al-Ahmady, Z., Mazza, M., Collins, R. F., Dawson, K., & Kostarelos, K. (2015) · ACS Nano · doi:10.1021/acsnano.5b03300 · Cited by 358
Clinical Trials: IL-12 Deaths: Explanation and a Puzzle
Cohen, J. (1995) · Science · doi:10.1126/science.270.5238.908a · Cited by 332
CNS Infection and Immune Privilege
Forrester, J. V., McMenamin, P. G., & Dando, S. J. (2018) · Nature Reviews Neuroscience · doi:10.1038/s41583-018-0070-8 · Cited by 313
Taylor, A. W. (2009) · Eye · doi:10.1038/eye.2008.382 · Cited by 253
Cited by
3D printing of functional microrobots
Li, J., & Pumera, M. (2021) · Chemical Society Reviews · doi:10.1039/d0cs01062f · Cited by 303
Photoacoustic Imaging-Trackable Magnetic Microswimmers for Pathogenic Bacterial Infection Treatment
Xie, L., Pang, X., Yan, X., Dai, Q., Lin, H., Ye, J., Cheng, Y., Zhao, Q., Ma, X., Zhang, X., et al. (2020) · ACS Nano · doi:10.1021/acsnano.9b06731 · Cited by 261
Ferromagnetic soft catheter robots for minimally invasive bioprinting
Zhou, C., Yang, Y., Wang, J., Wu, Q., Gu, Z., Zhou, Y., Liu, X., Yang, Y., Tang, H., Ling, Q., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-25386-w · Cited by 242
Metadata
- Authors
- Ceylan, H., Yasa, I. C., Kilic, U., Hu, W., & Sitti, M.
- Venue
- Progress in Biomedical Engineering
- Publisher
- IOP Publishing
- Published
- 2019-07-01
- Volume
- 1
- Issue
- 1
- Pages
- 012002
- ISSN
- 2516-1091 (ISSN-L)
- OpenAlex
- W2958330632
- Cited by
- 188
- References
- 10
- FWCI
- 13.04
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Translational prospects of untethered medical microrobots. https://app.cochat.ai/papers/10.1088/2516-1091/ab22d5
- The paper
- Ceylan, H., Yasa, I. C., Kilic, U., Hu, W., & Sitti, M. (2019). Translational prospects of untethered medical microrobots. Progress in Biomedical Engineering. https://doi.org/10.1088/2516-1091/ab22d5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.