The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Ultrastretchable Kirigami Bioprobes
Abstract
An ultrastretchable film device is developed that can follow the shape of spherical and large deformable biological samples such as heart and brain tissues. Although the film is composed of biocompatible parylene for the device substrate and metal layers of platinum (Pt)/titanium (Ti), which are unstretchable materials, the film shows a high stretchability by patterning slits as a “Kirigami” design. A Pt/Ti‐microelectrode array embedded in 11 µm thick parylene film with 5 × 91 slits exhibits a film strain of ≈250% at 9 mN strain‐force (0.08 MPa in stress) with a Young's modulus of 23 kPa, while the 3 × 91‐slit film shows a Young's modulus of 3.6 kPa. The maximum strains of these devices are ≈470% and ≈840%, respectively. It is demonstrated that the Kirigami‐based microelectrode device can simultaneously record in vivo electrocorticogram signals from the visual and barrel cortices of a mouse by stretching the film and tuning the electrode gap. Moreover, wrapping the Kirigami device around a beating mouse's heart, which shows large and rapid changes in the volume and the surface area, can record the in vivo epicardial electrocardiogram signals. Such a small Young's modulus for a stretchable device reduces the device's strain‐force, minimizing the device‐induced stress to soft biological tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tissue Cells Feel and Respond to the Stiffness of Their Substrate
Discher, D. E., Janmey, P., & Wang, Y.-L. (2005) · Science · doi:10.1126/science.1116995 · Cited by 6,382
Nanowire active-matrix circuitry for low-voltage macroscale artificial skin
Takei, K., Takahashi, T., Ho, J. C., Ko, H., Gillies, A. G., Leu, P. W., Fearing, R. S., & Javey, A. (2010) · Nature Materials · doi:10.1038/nmat2835 · Cited by 1,274
Cited by
Materials and structural designs of stretchable conductors
Matsuhisa, N., Chen, X., Bao, Z., & Someya, T. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00814k · Cited by 566
Natural Biopolymer-Based Biocompatible Conductors for Stretchable Bioelectronics
Wang, C., Yokota, T., & Someya, T. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00897 · Cited by 412
An adaptive ionic skin with multiple stimulus responses and moist-electric generation ability
Pan, X., Wang, Q., Guo, R., Cao, S., Wu, H., Ouyang, X., Huang, F., Gao, H., Huang, L., Zhang, F., et al. (2020) · Journal of Materials Chemistry A · doi:10.1039/c9ta13407g · Cited by 66
Biomedical Implants with Charge‐Transfer Monitoring and Regulating Abilities
Wang, D., Tan, J., Zhu, H., Mei, Y., & Liu, X. (2021) · Advanced Science · doi:10.1002/advs.202004393 · Cited by 49
Recent advances in recording and modulation technologies for next-generation neural interfaces.
Hong, J.-W., Yoon, C., Jo, K., Won, J. H., & Park, S. (2021) · iScience · doi:10.1016/j.isci.2021.103550 · Cited by 25
Metadata
- Authors
- Morikawa, Y., Yamagiwa, S., Sawahata, H., Numano, R., Koida, K., Ishida, M., & Kawano, T.
- Venue
- Advanced Healthcare Materials
- Publisher
- Wiley
- Published
- 2017-12-08
- Volume
- 7
- Issue
- 3
- ISSN
- 2192-2640 (ISSN-L)
- 2192-2659
- OpenAlex
- W2774943527
- Cited by
- 174
- References
- 2
- FWCI
- 4.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrastretchable Kirigami Bioprobes. https://app.cochat.ai/papers/10.1002/adhm.201701100
- The paper
- Morikawa, Y., Yamagiwa, S., Sawahata, H., Numano, R., Koida, K., Ishida, M., & Kawano, T. (2018). Ultrastretchable Kirigami Bioprobes. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.201701100
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.