CoChat

A pH‐Mediated Electronic Wound Dressing for Controlled Drug Delivery

Open access
Kiaee, Gita, Mostafalu, Pooria, Samandari, Mohamadmahdi, Sonkusale, Sameer · 2018 · Advanced Healthcare Materials
Cited by 105

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Topical administration of drugs in a timely manner according to the physiological need at the wound site can enhance the healing rate of chronic wounds. Herein, an electronic wound dressing that enables active topical drug delivery in response to electrically induced pH change is demonstrated for potential treatment of chronic wounds. In this platform, the pH of the dressing is controlled using an electrical field. This allows precise electrical control over the temporal profile of pH‐mediated drug release. This engineered dressing is comprised of microfabricated electrodes serving as anode and cathode, a pH sensitive hydrogel, and controlled electronic circuitry. The anode is coated with a pH sensitive poly(ethylene glycol)‐diacrylate/Laponite hydrogel layer containing drug loaded chitosan nanoparticles (ChPs). Applying a DC voltage between the electrodes results in a local change in pH near the electrodes. In basic environments found near the anode, the ChPs release their drug due to the dehydration process, while in acidic environments the release profile is negligible. Turning off the DC voltage results in immediate pH recovery and cessation of drug release. The biocompatibility of the dressing has also been confirmed—the pH shift resulting from application of DC voltage does not affect the wound pH significantly.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adhm.201800396

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 105

Metadata

Authors
Kiaee, G., Mostafalu, P., Samandari, M., & Sonkusale, S.
Venue
Advanced Healthcare Materials
Publisher
Wiley
Published
2018-08-02
Volume
7
Issue
18
Pages
e1800396-e1800396
ISSN
  • 2192-2640 (ISSN-L)
  • 2192-2659
OpenAlex
W2886533633
Cited by
105
References
2
FWCI
5.94
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A pH‐Mediated Electronic Wound Dressing for Controlled Drug Delivery. https://app.cochat.ai/papers/10.1002/adhm.201800396
The paper
Kiaee, G., Mostafalu, P., Samandari, M., & Sonkusale, S. (2018). A pH‐Mediated Electronic Wound Dressing for Controlled Drug Delivery. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.201800396

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.