An Injectable Strong Hydrogel for Bone Reconstruction
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
For treating bone defects in periarticular fractures, there is a lack of biomaterial with injectable characteristics, tough structure, and osteogenic capacity for providing a whole‐structure support and osteogenesis in the defect area. An injectable hydrogel is an ideal implant, however is weak as load‐bearing scaffolds. Herein, a new strategy, i.e., an in situ formation of “active” composite double network (DN), is raised for the preparation of an injectable strong hydrogel particularly against compression. As a demonstration, 4‐carboxyphenylboronic acid grafted poly(vinyl alcohol) (PVA) is crosslinked using calcium ions to provide a tough frame while bioactive glass (BG) microspheres are associated by poly(ethylene glycol) to obtain an interpenetrated inorganic network for reinforcement. The injected PVA/BG DN hydrogel gains compressive strength, modulus, and fracture energy of 34 MPa, 0.8 MPa, and 40 kJ m−2, respectively. Then, the properties can be “autostrengthened” to 57 MPa, 2 MPa, and 65 kJ m−2 by mineralization in 14 days. In vivo experiments prove that the injected DN hydrogel is more efficient to treat femoral supracondylar bone defects than the implanted bulk DN gel. The work suggests a facile way to obtain a strong hydrogel with injectability, cytocompatibility, and tailorable functionality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
THE MATERIAL BONE: Structure-Mechanical Function Relations
Weiner, S., & Wagner, H. D. (1998) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.28.1.271 · Cited by 2,724
Chen, Q., Zhu, L., Chen, H., Yan, H., Huang, L., Yang, J., & Zheng, J. (2015) · Advanced Functional Materials · doi:10.1002/adfm.201404357 · Cited by 632
Zheng, L., Jiang, X., Chen, X., Fan, H., & Zhang, X. (2014) · Biomedical Materials · doi:10.1088/1748-6041/9/6/065004 · Cited by 59
Cited by
Xu, X., Jerca, V. V., & Hoogenboom, R. (2021) · Materials Horizons · doi:10.1039/d0mh01514h · Cited by 532
Scaffolds for bone-tissue engineering
Lee, S. S., Du, X., Kim, I., & Ferguson, S. J. (2022) · Matter · doi:10.1016/j.matt.2022.06.003 · Cited by 375
Functional Biomaterials for Bone Regeneration: A Lesson in Complex Biology
Armiento, A. R., Hatt, L. P., Sanchez Rosenberg, G., Thompson, K., & Stoddart, M. J. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201909874 · Cited by 273
Recent advances of injectable hydrogels for drug delivery and tissue engineering applications
Sun, Y., Nan, D., Jin, H., & Qu, X. (2020) · Polymer Testing · doi:10.1016/j.polymertesting.2019.106283 · Cited by 227
Self-citationA Review on the Design of Hydrogels With Different Stiffness and Their Effects on Tissue Repair
Luo, T., Tan, B., Zhu, L., Wang, Y., & Liao, J. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.817391 · Cited by 172
Metadata
- Authors
- Zhao, Y., Cui, Z., Liu, B., Xiang, J., Qiu, D., Tian, Y., Qu, X., & Yang, Z.
- Venue
- Advanced Healthcare Materials
- Publisher
- Wiley
- Published
- 2019-07-28
- Volume
- 8
- Issue
- 17
- Pages
- e1900709-e1900709
- ISSN
- 2192-2640 (ISSN-L)
- 2192-2659
- OpenAlex
- W2965678757
- Cited by
- 112
- References
- 3
- FWCI
- 3.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Injectable Strong Hydrogel for Bone Reconstruction. https://app.cochat.ai/papers/10.1002/adhm.201900709
- The paper
- Zhao, Y., Cui, Z., Liu, B., Xiang, J., Qiu, D., Tian, Y., Qu, X., & Yang, Z. (2019). An Injectable Strong Hydrogel for Bone Reconstruction. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.201900709
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.