The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Highly Sensitive and Wearable Liquid Metal‐Based Pressure Sensor for Health Monitoring Applications: Integration of a 3D‐Printed Microbump Array with the Microchannel
Abstract
Wearable pressure sensors capable of sensitive, precise, and continuous measurement of physiological and physical signals have great potential for the monitoring of health status and the early diagnosis of diseases. This work introduces a 3D‐printed rigid microbump‐integrated liquid metal‐based soft pressure sensor (3D‐BLiPS) for wearable and health‐monitoring applications. Using a 3D‐printed master mold based on multimaterial fused deposition modeling, the fabrication of a liquid metal microchannel and the integration of a rigid microbump array above the microchannel are achieved in a one‐step, direct process. The microbump array enhances the sensitivity of the pressure sensor (0.158 kPa−1) by locally concentrating the deformation of the microchannel with negligible hysteresis and a stable signal response under cyclic loading. The 3D‐BLiPS also demonstrates excellent robustness to 10 000 cycles of multidirectional stretching/bending, changes in temperature, and immersion in water. Finally, these characteristics are suitable for a wide range of applications in health monitoring systems, including a wristband for the continuous monitoring of the epidermal pulse rate for cuffless blood pressure estimation and a wireless wearable device for the monitoring of body pressure using a multiple pressure sensor array for the prevention of pressure ulcers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935
Cuffless Blood Pressure Estimation Algorithms for Continuous Health-Care Monitoring
Kachuee, M., Kiani, M. M., Mohammadzade, H., & Shabany, M. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2580904 · Cited by 621
Cited by
Yang, R., Dutta, A., Li, B., Tiwari, N., Zhang, W., Niu, Z., Gao, Y., Erdely, D., Xin, X., Li, T., et al. (2023) · Nature Communications · doi:10.1038/s41467-023-38274-2 · Cited by 390
Shi, Z., Meng, L., Shi, X., Li, H., Zhang, J., Sun, Q., Liu, X., Chen, J., & Liu, S. (2022) · Nano-Micro Letters · doi:10.1007/s40820-022-00874-w · Cited by 282
Liquid Metal‐Based Soft Electronics for Wearable Healthcare
Park, Y., Lee, G., Jang, J., Yun, S. M., Kim, E., & Park, J. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202002280 · Cited by 258
Three-dimensional flexible electronics using solidified liquid metal with regulated plasticity
Li, G., Zhang, M., Liu, S., Yuan, M., Wu, J., Yu, M., Teng, L., Xu, Z., Guo, J., Li, G., et al. (2023) · Nature Electronics · doi:10.1038/s41928-022-00914-8 · Cited by 258
Metadata
- Authors
- Kim, K., Choi, J., Jeong, Y., Cho, I., Kim, M., Kim, S., Oh, Y., & Park, I.
- Venue
- Advanced Healthcare Materials
- Publisher
- Wiley
- Published
- 2019-10-09
- Volume
- 8
- Issue
- 22
- Pages
- e1900978-e1900978
- ISSN
- 2192-2640 (ISSN-L)
- 2192-2659
- OpenAlex
- W2979796094
- Cited by
- 186
- References
- 2
- FWCI
- 6.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly Sensitive and Wearable Liquid Metal‐Based Pressure Sensor for Health Monitoring Applications: Integration of a 3D‐Printed Microbump Array with the Microchannel. https://app.cochat.ai/papers/10.1002/adhm.201900978
- The paper
- Kim, K., Choi, J., Jeong, Y., Cho, I., Kim, M., Kim, S., Oh, Y., & Park, I. (2019). Highly Sensitive and Wearable Liquid Metal‐Based Pressure Sensor for Health Monitoring Applications: Integration of a 3D‐Printed Microbump Array with the Microchannel. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.201900978
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.