Cuffless Blood Pressure Estimation Algorithms for Continuous Health-Care Monitoring
Abstract
GOAL: Continuous blood pressure (BP) monitoring can provide invaluable information about individuals' health conditions. However, BP is conventionally measured using inconvenient cuff-based instruments, which prevents continuous BP monitoring. This paper presents an efficient algorithm, based on the pulse arrival time (PAT), for the continuous and cuffless estimation of the systolic BP, diastolic blood pressure (DBP), and mean arterial pressure (MAP) values. METHODS: The proposed framework estimates the BP values through processing vital signals and extracting two types of features, which are based on either physiological parameters or whole-based representation of vital signals. Finally, the regression algorithms are employed for the BP estimation. Although the proposed algorithm works reliably without any need for calibration, an optional calibration procedure is also suggested, which can improve the system's accuracy even further. RESULTS: The proposed method is evaluated on about a thousand subjects using the Association for the Advancement of Medical Instrumentation (AAMI) and the British Hypertension Society (BHS) standards. The method complies with the AAMI standard in the estimation of DBP and MAP values. Regarding the BHS protocol, the results achieve grade A for the estimation of DBP and grade B for the estimation of MAP. CONCLUSION: We conclude that by using the PAT in combination with informative features from the vital signals, the BP can be accurately and reliably estimated in a noninvasive fashion. SIGNIFICANCE: The results indicate that the proposed algorithm for the cuffless estimation of the BP can potentially enable mobile health-care gadgets to monitor the BP continuously.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In individuals with very large arm size, defined as arm circumference greater than 42 cm, the shape of the cuff is important because the large arm shape is troncoconical.
“In individuals with very large arm size (arm circumference >42 cm) the shape of the cuff is also important as the large arm shape is troncoconical [101,102].”
A rectangular or cylindrical shape cuff is unsuitable for very large arms because it cannot evenly compress the upper arm, and a troncoconical cuff shape seems more appropriate.
“Thus, a rectangular (cylindrical) shape cuff is unsuitable as it cannot evenly compress the upper arm and a troncoconical cuff shape seems to be more appropriate [101,102].”
There is still uncertainty on how to validate devices in people with a large arm size greater than 42 cm, as there are issues with the cuff size and shape of the reference auscultatory blood pressure measurement.
“However, there is still uncertainty on how to validate devices in people with a large arm size (i.e. >42 cm), as there are issues with the cuff size and shape of the reference (auscultatory) BP measurement as well [102].”
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538 · see citing works
LIBSVM: A library for support vector machines
Chang, C.-C., & Lin, C.-J. (2011) · ACM Transactions on Intelligent Systems and Technology · doi:10.1145/1961189.1961199 · Cited by 40,918 · see citing works
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809 · see citing works
On the Analysis of Fingertip Photoplethysmogram Signals
Elgendi, M. (2012) · Current Cardiology Reviews · doi:10.2174/157340312801215782 · Cited by 1,206 · see citing works
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935 · see citing works
Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressure
Payne, R. A., Symeonides, C. N., Webb, D. J., & Maxwell, S. R. J. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00657.2005 · Cited by 418 · see citing works
Peter, L., Noury, N., & Cerny, M. (2014) · IRBM · doi:10.1016/j.irbm.2014.07.002 · Cited by 261 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Flexible Hybrid Electronics for Digital Healthcare
Ma, Y., Zhang, Y., Cai, S., Han, Z., Liu, X., Wang, F., Cao, Y., Wang, Z., Li, H., Chen, Y., et al. (2020) · Advanced Materials · doi:10.1002/adma.201902062 · Cited by 620 · see citing works
The use of photoplethysmography for assessing hypertension
Elgendi, M., Fletcher, R., Liang, Y., Howard, N., Lovell, N. H., Abbott, D., Lim, K., & Ward, R. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0136-7 · Cited by 625 · see citing works
Blood Pressure Estimation from Photoplethysmogram Using a Spectro-Temporal Deep Neural Network
Slapničar, G., Mlakar, N., & Luštrek, M. (2019) · Sensors · doi:10.3390/s19153420 · Cited by 387 · see citing works
Cuff-Less and Continuous Blood Pressure Monitoring: A Methodological Review
Sharma, M., Barbosa, K., Ho, V., Griggs, D., Ghirmai, T., Krishnan, S., Hsiai, T., Chiao, J.-C., & Cao, H. (2017) · Technologies · doi:10.3390/technologies5020021 · Cited by 226 · see citing works
Evaluation of the Accuracy of Cuffless Blood Pressure Measurement Devices: Challenges and Proposals
Mukkamala, R., Yavarimanesh, M., Natarajan, K., Hahn, J.-O., Kyriakoulis, K. G., Avolio, A. P., & Stergiou, G. S. (2021) · Hypertension · doi:10.1161/hypertensionaha.121.17747 · Cited by 211 · see citing works
Parati, G., Stergiou, G. S., Bilo, G., Kollias, A., Pengo, M., Ochoa, J. E., Agarwal, R., Asayama, K., Asmar, R., Burnier, M., et al. (2021) · Journal of Hypertension · doi:10.1097/hjh.0000000000002922 · Cited by 178 · see citing works
Toward an AI Era: Advances in Electronic Skins
Fu, X., Cheng, W., Wan, G., Yang, Z., & Tee, B. C. K. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.4c00049 · Cited by 172 · see citing works
PPG2ABP: Translating photoplethysmogram (PPG) signals to arterial blood pressure (ABP) waveforms
Ibtehaz, N., Mahmud, S., Chowdhury, M. E. H., Khandakar, A., Salman Khan, M., Ayari, M. A., Tahir, A. M., & Rahman, M. S. (2022) · Bioengineering · doi:10.3390/bioengineering9110692 · Cited by 133 · see citing works
Photoplethysmography signal processing and synthesis
Mejía-Mejía, E., Allen, J., Budidha, K., El-Hajj, C., Kyriacou, P. A., & Charlton, P. H. (2022) · Photoplethysmography · doi:10.1016/b978-0-12-823374-0.00015-3 · Cited by 138 · see citing works
Large-Scale Distributed Dedicated- and Non-Dedicated Smart City Sensing Systems
Habibzadeh, H., Qin, Z., Soyata, T., & Kantarci, B. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2725638 · Cited by 114 · see citing works
Cuffless Blood Pressure Monitoring: Promises and Challenges
Pandit, J. A., Lores, E., & Batlle, D. (2020) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.03680320 · Cited by 101 · see citing works
Shi, C., Zhang, H., Ni, X., & Wang, K. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3311052 · Cited by 33 · see citing works
tinyCare: A tinyML-based Low-Cost Continuous Blood Pressure Estimation on the Extreme Edge
Ahmed, K., & Hassan, M. (2022) · 2022 IEEE 10th International Conference on Healthcare Informatics (ICHI) · doi:10.1109/ichi54592.2022.00047 · Cited by 29 · see citing works
Sex-Related Differences in Photoplethysmography Signals Measured From Finger and Toe
Dehghanojamahalleh, S., & Kaya, M. (2019) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2019.2938506 · Cited by 25 · see citing works
- Authors
- Kachuee, M., Kiani, M. M., Mohammadzade, H., & Shabany, M.
- Affiliations
- Sharif University of Technology (IR)
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2017-04
- Volume
- 64
- Issue
- 4
- Pages
- 859-869
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2431637923
- Cited by
- 621
- References
- 7
- Citations by year
- 2026: 50 · 2025: 70 · 2024: 67 · 2023: 101 · 2022: 95 · 2021: 88 · 2020: 60 · 2019: 47 · 2018: 29 · 2017: 14
- FWCI
- 14.46
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Keywords
- cuffless blood pressure measurement, pulse arrival time, continuous blood pressure monitoring, systolic blood pressure, diastolic blood pressure, mean arterial pressure, vital signs, regression estimation, calibration, non-invasive blood pressure measurement, mobile health monitoring
- MeSH terms
- Machine Learning, Algorithms, Blood Pressure, Blood Pressure Determination, Diagnosis, Computer-Assisted, Equipment Design, Humans, Sensitivity and Specificity, Reproducibility of Results, Blood Pressure Monitors, Monitoring, Ambulatory, Equipment Failure Analysis, Pulse Wave Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review