CoChat

3D Bioprinting of Oxygenated Cell‐Laden Gelatin Methacryloyl Constructs

Open access
Erdem, Ahmet, Darabi, Mohammad Ali, Nasiri, Rohollah, Sangabathuni, Sivakoti, Ertas, Yavuz Nuri, Alem, Halima, Hosseini, Vahid, Shamloo, Amir, Nasr, Ali S., Ahadian, Samad, Dokmeci, Mehmet R., Khademhosseini, Ali, Ashammakhi, Nureddin · 2020 · Advanced Healthcare Materials
Cited by 148

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Cell survival during the early stages of transplantation and before new blood vessels formation is a major challenge in translational applications of 3D bioprinted tissues. Supplementing oxygen (O 2) to transplanted cells via an O 2 generating source such as calcium peroxide (CPO) is an attractive approach to ensure cell viability. Calcium peroxide also produces calcium hydroxide that reduces the viscosity of bioinks, which is a limiting factor for bioprinting. Therefore, adapting this solution into 3D bioprinting is of significant importance. In this study, a gelatin methacryloyl (GelMA) bioink that is optimized in terms of pH and viscosity is developed. The improved rheological properties lead to the production of a robust bioink suitable for 3D bioprinting and controlled O 2 release. In addition, O 2 release, bioprinting conditions, and mechanical performance of hydrogels having different CPO concentrations are characterized. As a proof of concept study, fibroblasts and cardiomyocytes are bioprinted using CPO containing GelMA bioink. Viability and metabolic activity of printed cells are checked after 7 days of culture under hypoxic condition. The results show that the addition of CPO improves the metabolic activity and viability of cells in bioprinted constructs under hypoxic condition.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adhm.201901794

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 148

Metadata

Authors
Erdem, A., Darabi, M. A., Nasiri, R., Sangabathuni, S., Ertas, Y. N., Alem, H., Hosseini, V., Shamloo, A., Nasr, A. S., Ahadian, S., Dokmeci, M. R., Khademhosseini, A., & Ashammakhi, N.
Venue
Advanced Healthcare Materials
Publisher
Wiley
Published
2020-06-16
Volume
9
Issue
15
Pages
e1901794-e1901794
ISSN
  • 2192-2640 (ISSN-L)
  • 2192-2659
OpenAlex
W3035486498
Cited by
148
References
3
FWCI
6.71
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: 3D Bioprinting of Oxygenated Cell‐Laden Gelatin Methacryloyl Constructs. https://app.cochat.ai/papers/10.1002/adhm.201901794
The paper
Erdem, A., Darabi, M. A., Nasiri, R., Sangabathuni, S., Ertas, Y. N., Alem, H., Hosseini, V., Shamloo, A., Nasr, A. S., Ahadian, S., Dokmeci, M. R., Khademhosseini, A., & Ashammakhi, N. (2020). 3D Bioprinting of Oxygenated Cell‐Laden Gelatin Methacryloyl Constructs. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.201901794

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.