Stretchable Electrodes with High Conductivity and Photo‐Patternability
The DOI matches its Crossref record.
Abstract
Electrically conductive materials that are elastomeric and photopatternable are presented. They are capable of achieving strains of up to 150% and thousands of cycles while retaining a low Young's modulus and low resistance. These compliant electrodes are made by mixing platinum salt into an elastomeric photo-polymer, exposing the film to UV light and developing, and then chemically reducing the Pt.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A stretchable carbon nanotube strain sensor for human-motion detection
Yamada, T., Hayamizu, Y., Yamamoto, Y., Yomogida, Y., Izadi-Najafabadi, A., Futaba, D. N., & Hata, K. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.36 · Cited by 3,247
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
Nature-Inspired Structural Materials for Flexible Electronic Devices
Liu, Y., He, K., Chen, G., Leow, W. R., & Chen, X. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00291 · Cited by 798
Materials and Structures toward Soft Electronics
Wang, C., Wang, C., Huang, Z., & Xu, S. (2018) · Advanced Materials · doi:10.1002/adma.201801368 · Cited by 662
Stretchable Electronics: Materials Strategies and Devices
Kim, D., & Rogers, J. A. (2008) · Advanced Materials · doi:10.1002/adma.200801788 · Cited by 648
Flexible and stretchable electrodes for dielectric elastomer actuators
Rosset, S., & Shea, H. R. (2013) · Applied Physics A · doi:10.1007/s00339-012-7402-8 · Cited by 529
Niu, Z., Dong, H., Zhu, B., Li, J., Hng, H. H., Zhou, W., Chen, X., & Xie, S. (2013) · Advanced Materials · doi:10.1002/adma.201204003 · Cited by 523
Flexible Hybrid Sensors for Health Monitoring: Materials and Mechanisms to Render Wearability
Gao, Y., Yu, L., Yeo, J. C., & Lim, C. T. (2020) · Advanced Materials · doi:10.1002/adma.201902133 · Cited by 505
Robotic Artificial Muscles: Current Progress and Future Perspectives
Zhang, J., Sheng, J., O'Neill, C. T., Walsh, C. J., Wood, R. J., Ryu, J.-H., Desai, J. P., & Yip, M. C. (2019) · IEEE Transactions on Robotics · doi:10.1109/tro.2019.2894371 · Cited by 398
Design of conductive composite elastomers for stretchable electronics
Park, M., Park, J., & Jeong, U. (2014) · Nano Today · doi:10.1016/j.nantod.2014.04.009 · Cited by 295
Recent Advances in Stretchable and Transparent Electronic Materials
McCoul, D., Hu, W., Gao, M., Mehta, V., & Pei, Q. (2016) · Advanced Electronic Materials · doi:10.1002/aelm.201500407 · Cited by 293
Highly stretchable, conductive, and transparent nanotube thin films
Hu, L., Yuan, W., Brochu, P., Gruner, G., & Pei, Q. (2009) · Applied Physics Letters · doi:10.1063/1.3114463 · Cited by 177
Sasaki, M., Karikkineth, B. C., Nagamine, K., Kaji, H., Torimitsu, K., & Nishizawa, M. (2014) · Advanced Healthcare Materials · doi:10.1002/adhm.201400209 · Cited by 169
Metadata
- Authors
- Urdaneta, M. G., Delille, R., & Smela, E.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2007-08-15
- Volume
- 19
- Issue
- 18
- Pages
- 2629-2633
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W2142866890
- Cited by
- 61
- References
- 0
- FWCI
- 2.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.