Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.

Highly Conductive Stretchable and Biocompatible Electrode–Hydrogel Hybrids for Advanced Tissue Engineering

Abstract

Hydrogel‐based, molecular permeable electronic devices are considered to be promising for electrical stimulation and recording of living tissues, either in vivo or in vitro. This study reports the fabrication of the first hydrogel‐based devices that remain highly electrically conductive under substantial stretch and bending. Using a simple technique involving a combination of chemical polymerization and electropolymerization of poly (3,4‐ethylenedioxythiophene) (PEDOT), a tight bonding of a conductive composite of PEDOT and polyurethane (PU) to an elastic double‐network hydrogel is achieved to make fully organic PEDOT/PU–hydrogel hybrids. Their response to repeated bending, mechanical stretching, hydration‐dessication cycles, storage in aqueous condition for up to 6 months, and autoclaving is assessed, demonstrating excellent stability, without any mechanical or electrical damage. The hybrids exhibit a high electrical conductivity of up to 120 S cm −1 at 100% elongation. The adhesion, proliferation, and differentiation of neural and muscle cells cultured on these hybrids are demonstrated, as well as the fabrication of 3D hybrids, advancing the field of tissue engineering with integrated electronics.

Overview

Integrity signals

Registry

Crossref · 10.1002/adhm.201400209

Cites

59 of 59 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 59 references

Research works printed but not linked: 3

  1. Tang‐Schomer M. D., 2013, Adv. Funct. Mater., 24, 1934
  2. Miriani R. M., 2008, Conf. Proc. IEEE Eng. Med. Biol. Soc., 2008, 1841
  3. Wilks S. J., 2011, Conf. Proc. IEEE Eng. Med. Biol. Soc., 2011, 5412

Cited by

See all 169

Metadata

Authors
Sasaki, M., Karikkineth, B. C., Nagamine, K., Kaji, H., Torimitsu, K., & Nishizawa, M.
Affiliations
Tohoku University (JP)
Corresponding author
  • Karikkineth, Bijoy Chandapillai
  • Nishizawa, Matsuhiko
Venue
Advanced Healthcare Materials
Publisher
Wiley
Published
2014-06-10
Volume
3
Issue
11
Pages
1919-1927
ISSN
  • 2192-2640 (ISSN-L)
  • 2192-2659
OpenAlex
W2059610514
Cited by
169
References
59
Citations by year
2026: 7 · 2025: 11 · 2024: 9 · 2023: 7 · 2022: 10 · 2021: 25 · 2020: 26 · 2019: 21 · 2018: 14 · 2017: 16 · 2016: 12 · 2015: 10 · 2014: 1
FWCI
9.07
Type
journal article
Language
en
Open access
closed
Locations
  • Advanced Healthcare Materials (publishedVersion)
  • PubMed (publishedVersion)
Funders
Japan Society for the Promotion of Science (25790031, 25246016, 25600053, 26286031)
Topics
  • Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
Keywords
stretchable electrodes, PEDOT, polyurethane, double-network hydrogel, electropolymerization, chemical polymerization, electrical conductivity, neuronal adhesion, muscle cell differentiation, tissue engineering, 3D printed electronics, biocompatibility
MeSH terms
Animals, Cell Line, Electric Conductivity, Electrodes, Polymers, Polyurethanes, Bridged Bicyclo Compounds, Heterocyclic, Hydrogel, Polyethylene Glycol Dimethacrylate, Tissue Engineering, Mice

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Highly Conductive Stretchable and Biocompatible Electrode–Hydrogel Hybrids for Advanced Tissue Engineering. https://app.cochat.ai/papers/10.1002/adhm.201400209
The paper
Sasaki, M., Karikkineth, B. C., Nagamine, K., Kaji, H., Torimitsu, K., & Nishizawa, M. (2014). Highly Conductive Stretchable and Biocompatible Electrode–Hydrogel Hybrids for Advanced Tissue Engineering. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.201400209

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.