The DOI matches its Crossref record.
Dynamic Imaging of Functionalized Multi‐Walled Carbon Nanotube Systemic Circulation and Urinary Excretion
Abstract
Intravenously administered multi-walled carbon nanotubes, functionalized with DTPA and radiolabeled with Indium-111, were dynamically tracked in vivo using a microSingle Photon Emission Tomography scanner. Imaging showed that nanotubes enter the systemic blood circulation and within 5 min begin to permeate through the renal glomerular filtration system into the bladder.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Understanding biophysicochemical interactions at the nano–bio interface
Nel, A. E., Mädler, L., Velegol, D., Xia, T., Hoek, E. M. V., Somasundaran, P., Klaessig, F., Castranova, V., & Thompson, M. (2009) · Nature Materials · doi:10.1038/nmat2442 · Cited by 7,083
Sharifi, S., Behzadi, S., Laurent, S., Laird Forrest, M., Stroeve, P., & Mahmoudi, M. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15188f · Cited by 1,460
Promises, facts and challenges for carbon nanotubes in imaging and therapeutics
Kostarelos, K., Bianco, A., & Prato, M. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.241 · Cited by 787
Self-citationEfficient water oxidation at carbon nanotube–polyoxometalate electrocatalytic interfaces
Toma, F. M., Sartorel, A., Iurlo, M., Carraro, M., Parisse, P., Maccato, C., Rapino, S., Gonzalez, B. R., Amenitsch, H., Da Ros, T., et al. (2010) · Nature Chemistry · doi:10.1038/nchem.761 · Cited by 503
Self-citationParadoxical glomerular filtration of carbon nanotubes
Ruggiero, A., Villa, C. H., Bander, E., Rey, D. A., Bergkvist, M., Batt, C. A., Manova-Todorova, K., Deen, W. M., Scheinberg, D. A., & McDevitt, M. R. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0913667107 · Cited by 404
Metadata
- Authors
- Lacerda, L., Soundararajan, A., Singh, R., Pastorin, G., Al‐Jamal, K. T., Turton, J., Frederik, P., Herrero, M. A., Li, S., Bao, A., Emfietzoglou, D., Mather, S., Phillips, W. T., Prato, M., Bianco, A., Goins, B., & Kostarelos, K.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2007-12-11
- Volume
- 20
- Issue
- 2
- Pages
- 225-230
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W2116564247
- Cited by
- 211
- References
- 0
- FWCI
- 9.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dynamic Imaging of Functionalized Multi‐Walled Carbon Nanotube Systemic Circulation and Urinary Excretion. https://app.cochat.ai/papers/10.1002/adma.200702334
- The paper
- Lacerda, L., Soundararajan, A., Singh, R., Pastorin, G., Al‐Jamal, K. T., Turton, J., Frederik, P., Herrero, M. A., Li, S., Bao, A., Emfietzoglou, D., Mather, S., Phillips, W. T., Prato, M., Bianco, A., Goins, B., & Kostarelos, K. (2008). Dynamic Imaging of Functionalized Multi‐Walled Carbon Nanotube Systemic Circulation and Urinary Excretion. Advanced Materials. https://doi.org/10.1002/adma.200702334
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.