The DOI matches its Crossref record.
Polydiacetylene–Liposome Microarrays for Selective and Sensitive Mercury(II) Detection
Abstract
Polydiacetylene (PDA) liposome microarrays are developed for selective and sensitive mercury (Hg2+) detection. The PDA mercury sensors are designed to produce red fluorescence emission upon binding with Hg2+, when the ssDNA aptamers on the PDA surface recognize and wrap around mercury ions and the resulting bulky T-Hg-T complexes repulse each other.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dave, N., Chan, M. Y., Huang, P.-J. J., Smith, B. D., & Liu, J. (2010) · Journal of the American Chemical Society · doi:10.1021/ja106098j · Cited by 461
Photonic Nanosensor for Colorimetric Detection of Metal Ions
Yetisen, A. K., Montelongo, Y., Qasim, M. M., Butt, H., Wilkinson, T. D., Monteiro, M. J., & Yun, S. H. (2015) · Analytical Chemistry · doi:10.1021/ac504274q · Cited by 94
Metadata
- Authors
- Lee, J., Jun, H., & Kim, J.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2009-09-22
- Volume
- 21
- Issue
- 36
- Pages
- 3674-3677
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W1973987550
- Cited by
- 213
- References
- 0
- FWCI
- 8.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Polydiacetylene–Liposome Microarrays for Selective and Sensitive Mercury(II) Detection. https://app.cochat.ai/papers/10.1002/adma.200900639
- The paper
- Lee, J., Jun, H., & Kim, J. (2009). Polydiacetylene–Liposome Microarrays for Selective and Sensitive Mercury(II) Detection. Advanced Materials. https://doi.org/10.1002/adma.200900639
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.