The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Biodegradable Materials for Multilayer Transient Printed Circuit Boards
Abstract
Biodegradable printed circuit boards based on water-soluble materials are demonstrated. These systems can dissolve in water within 10 mins to yield end-products that are environmentally safe. These and related approaches have the potential to reduce hazardous waste streams associated with electronics disposal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kirkpatrick, S. (1973) · Reviews of Modern Physics · doi:10.1103/revmodphys.45.574 · Cited by 5,260
Poly Lactic-co-Glycolic Acid (PLGA) as Biodegradable Controlled Drug Delivery Carrier
Makadia, H. K., & Siegel, S. J. (2011) · Polymers · doi:10.3390/polym3031377 · Cited by 4,816
Synthetic biodegradable polymers as orthopedic devices
Middleton, J. C., & Tipton, A. J. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00101-0 · Cited by 2,741
A Physically Transient Form of Silicon Electronics
Hwang, S.-W., Tao, H., Kim, D.-H., Cheng, H., Song, J.-K., Rill, E., Brenckle, M. A., Panilaitis, B., Won, S. M., Kim, Y.-S., et al. (2012) · Science · doi:10.1126/science.1226325 · Cited by 1,286
Self-citationOrthopaedic applications for PLA‐PGA biodegradable polymers
Athanasiou, K., Agrawal, C., Barber, F., & Burkhart, S. (1998) · Arthroscopy · doi:10.1016/s0749-8063(98)70099-4 · Cited by 487
Cited by
Bioresorbable silicon electronic sensors for the brain
Kang, S.-K., Murphy, R. K. J., Hwang, S.-W., Lee, S. M., Harburg, D. V., Krueger, N. A., Shin, J., Gamble, P., Cheng, H., Yu, S., et al. (2016) · Nature · doi:10.1038/nature16492 · Cited by 998
Self-citationTransient Electronics: Materials and Devices
Fu, K. K., Wang, Z., Dai, J., Carter, M., & Hu, L. (2016) · Chemistry of Materials · doi:10.1021/acs.chemmater.5b04931 · Cited by 371
Liquid Metal‐Based Transient Circuits for Flexible and Recyclable Electronics
Teng, L., Ye, S., Handschuh‐Wang, S., Zhou, X., Gan, T., & Zhou, X. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201808739 · Cited by 323
Flexible Artificial Sensory Systems Based on Neuromorphic Devices
Sun, F., Lu, Q., Feng, S., & Zhang, T. (2021) · ACS Nano · doi:10.1021/acsnano.0c10049 · Cited by 286
Design, manufacturing and applications of wearable triboelectric nanogenerators
Wang, H., Han, M., Song, Y., & Zhang, H. (2021) · Nano Energy · doi:10.1016/j.nanoen.2020.105627 · Cited by 179
Metadata
- Authors
- Huang, X., Liu, Y., Hwang, S., Kang, S., Patnaik, D., Cortes, J. F., & Rogers, J. A.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2014-09-22
- Volume
- 26
- Issue
- 43
- Pages
- 7371-7377
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W4249124298
- Cited by
- 162
- References
- 5
- FWCI
- 6.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biodegradable Materials for Multilayer Transient Printed Circuit Boards. https://app.cochat.ai/papers/10.1002/adma.201403164
- The paper
- Huang, X., Liu, Y., Hwang, S., Kang, S., Patnaik, D., Cortes, J. F., & Rogers, J. A. (2014). Biodegradable Materials for Multilayer Transient Printed Circuit Boards. Advanced Materials. https://doi.org/10.1002/adma.201403164
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.