Cited by 148Silk-based biomaterials and applicationsAdvanced Materials and MechanicsAdvanced Fiber Optic Sensors

The Use of Functionalized Silk Fibroin Films as a Platform for Optical Diffraction‐Based Sensing Applications

Zhou, Zhitao, Shi, Zhifeng, Cai, Xiaoqing, Zhang, Shaoqing, Corder, Stephanie G., Li, Xinxin, Zhang, Yeshun, Zhang, Guozheng +7 more·2017·Advanced Materials

Abstract

A set of biocompatible, biodegradable, and biofunctionalizable diffractive optical elements (DOEs) using silk proteins as the building materials is reported. The diffraction pattern of a DOE is highly sensitive to the surrounding environment and the structural integrity, offering numerous opportunities for biosensing applications.

Integrity signals

Registry

Crossref · 10.1002/adma.201605471

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • In vivo animal models possess limitations: species-specific differences between animals and humans cause differences in drug efficacy and toxicity tests in physiology and cell biology.

    “Species-specific differences between animals and humans cause differences in drug efficacy and toxicity tests in physiology and cell biology31–37.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Zhou, Z., Shi, Z., Cai, X., Zhang, S., Corder, S. G., Li, X., Zhang, Y., Zhang, G., Chen, L., Liu, M., Kaplan, D. L., Omenetto, F. G., Mao, Y., Tao, Z., & Tao, T. H.
Affiliations
  • Chinese Academy of Sciences (CN)
  • Shanghai Medical College of Fudan University (CN)
  • The University of Texas at Austin (US)
  • Department of Physics and Astronomy Stony Brook University Stony Brook NY 11794 USA
  • Jiangsu University of Science and Technology (CN)
  • Stony Brook University (US)
  • Tufts University (US)
  • Second Hospital of Nanchang (CN)
Corresponding author
  • Tao, Zhendong
  • Tao, Tiger H.
Venue
Advanced Materials
Publisher
Wiley
Published
2017-02-13
Volume
29
Issue
15
ISSN
  • 0935-9648 (ISSN-L)
  • 1521-4095
OpenAlex
W2588839040
Cited by
148
References
20
Citations by year
2026: 6 · 2025: 4 · 2024: 8 · 2023: 15 · 2022: 22 · 2021: 20 · 2020: 20 · 2019: 22 · 2018: 24 · 2017: 7
FWCI
7.18
Type
journal article
Language
en
Open access
closed
Locations
  • Advanced Materials (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Natural Science Foundation of China (61574156, 61527818)
  • Ministry of Science and Technology of the People's Republic of China (2016YFA0200800)
  • Natural Science Foundation of Jiangsu Province (BK20160554)
  • Science and Technology Commission of Shanghai Municipality
  • Natural Science Foundation of Shanghai (16JC1420100)
  • Directorate for Engineering (1563422, 1562915)
Topics
  • Physical Sciences › Materials Science › Biomaterials › Silk-based biomaterials and applications
  • Physical Sciences › Engineering › Mechanical Engineering › Advanced Materials and Mechanics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Fiber Optic Sensors
Keywords
silk fibroin, diffractive optical elements, light diffraction, biosensing, biodegradable materials, biomaterials, biofunctionalization
MeSH terms
Animals, Biocompatible Materials, Fibroins, Bombyx, Silk, Optical Devices

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review