The DOI matches its Crossref record; 234 of the 234 references it cites were found in a registry or an index.
Biomaterials and Advanced Technologies for Hemostatic Management of Bleeding
Open accessAbstract
Bleeding complications arising from trauma, surgery, and as congenital, disease‐associated, or drug‐induced blood disorders can cause significant morbidities and mortalities in civilian and military populations. Therefore, stoppage of bleeding (hemostasis) is of paramount clinical significance in prophylactic, surgical, and emergency scenarios. For externally accessible injuries, a variety of natural and synthetic biomaterials have undergone robust research, leading to hemostatic technologies including glues, bandages, tamponades, tourniquets, dressings, and procoagulant powders. In contrast, treatment of internal noncompressible hemorrhage still heavily depends on transfusion of whole blood or blood's hemostatic components (platelets, fibrinogen, and coagulation factors). Transfusion of platelets poses significant challenges of limited availability, high cost, contamination risks, short shelf‐life, low portability, performance variability, and immunological side effects, while use of fibrinogen or coagulation factors provides only partial mechanisms for hemostasis. With such considerations, significant interdisciplinary research endeavors have been focused on developing materials and technologies that can be manufactured conveniently, sterilized to minimize contamination and enhance shelf‐life, and administered intravenously to mimic, leverage, and amplify physiological hemostatic mechanisms. Here, a comprehensive review regarding the various topical, intracavitary, and intravenous hemostatic technologies in terms of materials, mechanisms, and state‐of‐art is provided, and challenges and opportunities to help advancement of the field are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Items 201–234 of 234
An evidence-based review of the use of a combat gauze (QuikClot) for hemorrhage control.
Gegel, B. T., Austin, P. N., & Johnson, D. (2013) · PubMed · Cited by 44
Okamura, Y., Takeoka, S., Teramura, Y., Maruyama, H., Tsuchida, E., Handa, M., & Ikeda, Y. (2005) · Transfusion · doi:10.1111/j.1537-2995.2005.00173.x · Cited by 43
Self-expanding foam for prehospital treatment of severe intra-abdominal hemorrhage
Peev, M. P., Rago, A. P., Hwabejire, J. O., Duggan, M., Beagle, J., Marini, J., Zugates, G., Busold, R., Freyman, T. M., Velmahos, G. C., et al. (2014) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0000000000000126 · Cited by 43
Haemostyptic preparations on the basis of collagen alone and as fixed combination with fibrin glue
Schiele, U., Kuntz, G., & Riegler, A. (1992) · Clinical Materials · doi:10.1016/0267-6605(92)90097-d · Cited by 40
Wound‐healing properties of trehalose‐stabilized freeze‐dried outdated platelets
Sum, R., Hager, S., Pietramaggiori, G., Orgill, D. P., Dee, J., Rudolph, A. S., Orser, C., Fitzpatrick, G. M., & Ho, D. H. (2007) · Transfusion · doi:10.1111/j.1537-2995.2007.01170.x · Cited by 40
Wang, R., Zhou, B., Liu, W., Feng, X., Li, S., Yu, D.-F., Chang, J., Chi, B., & Xu, H. L. (2014) · Journal of Biomaterials Applications · doi:10.1177/0885328214553960 · Cited by 39
New generation tissue sealants and hemostatic agents: innovative urologic applications.
Traver, M. A., & Assimos, D. G. (2006) · PubMed · Cited by 38
Cell-Based Models of Coagulation: A Paradigm in Evolution
Becker, R. C. (2005) · Journal of Thrombosis and Thrombolysis · doi:10.1007/s11239-005-3118-3 · Cited by 38
Applying results from clinical trials: tranexamic acid in trauma patients
Roberts, I., & Prieto‐Merino, D. (2014) · Journal of Intensive Care · doi:10.1186/s40560-014-0056-1 · Cited by 38
Pharmacologic treatment options in patients with thrombocytopenia
Demetri, G. D. (2000) · Seminars in Hematology · doi:10.1016/s0037-1963(00)90048-9 · Cited by 37
Biomaterials for Hemorrhage Control
Peng, T. (2010) · Trends in Biomaterials and Artificial Organs · Cited by 36
Intravenous hemostats: challenges in translation to patients
Lashof-Sullivan, M. M., Shoffstall, A. J., & Lavik, E. (2013) · Nanoscale · doi:10.1039/c3nr03595f · Cited by 36
Current concepts in platelet transfusion
Mohanty, D. (2009) · Asian Journal of Transfusion Science · doi:10.4103/0973-6247.45257 · Cited by 34
Pasic, M., Unbehaun, A., Drews, T., & Hetzer, R. (2011) · Interactive Cardiovascular and Thoracic Surgery · doi:10.1510/icvts.2011.276360 · Cited by 34
Okamura, Y., Fujie, T., Nogawa, M., Maruyama, H., Handa, M., Ikeda, Y., & Takeoka, S. (2008) · Transfusion Medicine · doi:10.1111/j.1365-3148.2008.00860.x · Cited by 33
A rapidly resorbable hemostatic biomaterial based on dihydroxyacetone
Henderson, P. W., Kadouch, D. J. M., Singh, S. P., Zawaneh, P. N., Weiser, J. R., Yazdi, S., Weinstein, A. L., Krotscheck, U., Wechsler, B., Putnam, D. A., et al. (2009) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32586 · Cited by 32
Blood compatibility of polymers derived from natural materials
Fedel, M., Tanır, T. E., Hasırcı, N., Maniglio, D., Morelli, A., Chiellini, E., & Motta, A. (2012) · Journal of Bioactive and Compatible Polymers · doi:10.1177/0883911512446060 · Cited by 30
Recombinant biologics for treatment of bleeding disorders
Bishop, P. D., & Lawson, J. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1443 · Cited by 29
Tachocomb used in endoscopic surgery
Scheyer, M., & Zimmermann, G. (1996) · Surgical Endoscopy · doi:10.1007/bf00188394 · Cited by 29
A Platelet-Inspired Paradigm for Nanomedicine Targeted to Multiple Diseases
Modery-Pawlowski, C. L., Kuo, H.-H., rd, W. M. B., & Gupta, A. S. (2013) · Nanomedicine · doi:10.2217/nnm.13.113 · Cited by 27
Self-citationRecombinant factor VIIa in trauma patients with the ‘triad of death’
Mitra, B., Cameron, P. A., Parr, M. J., & Phillips, L. E. (2011) · Injury · doi:10.1016/j.injury.2011.01.033 · Cited by 27
A Porcine Epistaxis Model: Hemostatic Effects of Octylcyanoacrylate
Singer, A. J., McClain, S. A., & Katz, A. E. (2004) · Otolaryngology · doi:10.1016/j.otohns.2003.09.035 · Cited by 25
Leixnering, M., Reichetseder, J., Schultz, A. E., Figl, M., Wassermann, E., Thurnher, M., & Redl, H. R. (2008) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0b013e3180340de1 · Cited by 24
Haemophilia 2002: emerging risks of treatment
Evatt, B. L., Farrugia, A., Shapiro, A. D., & Wilde, J. (2002) · Haemophilia · doi:10.1046/j.1365-2516.2002.00612.x · Cited by 24
Development of a recombinant human collagen‐type III based hemostat
Yang, C., Hillas, P. J., Tang, J. Z., Balan, J., Notbohm, H., & Polarek, J. W. (2003) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.20030 · Cited by 24
Cejas, M. A., Chen, C., Kinney, W. A., & Maryanoff, B. E. (2007) · Bioconjugate Chemistry · doi:10.1021/bc070105s · Cited by 22
Ryan, K. L., Cortez, D. S., Dick, E. J., et al. (2006) · Resuscitation · doi:10.1016/j.resuscitation.2005.11.008 · Cited by 21
Kodama, K. (1997) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/s1010-7940(96)01006-8 · Cited by 21
Briggs, A., & Askari, R. (2016) · International Journal of Surgery · doi:10.1016/j.ijsu.2016.03.064 · Cited by 18
Izumi, Y., Gika, M., Shinya, N., Miyabashira, S., Imamura, T., Nozaki, C., Kawamura, M., & Kobayashi, K. (2007) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0b013e318151ffdc · Cited by 16
Oxidized Regenerated Cellulose Gauze for Hemostasis of a Two-Stage Interpolation Flap Pedicle
Christenson, L. J., Otley, C. C., & Roenigk, R. K. (2004) · Dermatologic Surgery · doi:10.1097/00042728-200412020-00026 · Cited by 14
Rothwell, S. W., Settle, T., Wallace, S. M., Dorsey, J., Simpson, D. J. W., Bowman, J. R., Janmey, P. A., & Sawyer, E. S. (2010) · Biologicals · doi:10.1016/j.biologicals.2010.07.001 · Cited by 14
Edwards, J. V., Graves, E. E., Bopp, A. F., Prevost, N. T., Cintrón, M. S., & Condon, B. (2014) · Journal of Functional Biomaterials · doi:10.3390/jfb5040273 · Cited by 12
Effective application of fibrin sealant using a spray device with a double-tube structure
Fukunaga, N., Uchida, T., Kaetsu, H., et al. (1998) · International Journal of Adhesion and Adhesives · doi:10.1016/s0143-7496(98)00016-5 · Cited by 10
Cited by
Haemostatic materials for wound healing applications
Guo, B., Dong, R., Liang, Y., & Li, M. (2021) · Nature Reviews Chemistry · doi:10.1038/s41570-021-00323-z · Cited by 992
Nam, S., & Mooney, D. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00798 · Cited by 764
Supramolecular Adhesive Hydrogels for Tissue Engineering Applications
Zhao, Y., Song, S., Ren, X., Zhang, J., Lin, Q., & Zhao, Y. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00815 · Cited by 711
Polymeric hydrogel systems as emerging biomaterial platforms to enable hemostasis and wound healing
Pourshahrestani, S., Zeimaran, E., Kadri, N. A., Mutlu, N., & Boccaccini, A. R. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.202000905 · Cited by 448
Ren, H., Zhang, Z., Cheng, X., Zou, Z., Chen, X., & He, C. (2023) · Science Advances · doi:10.1126/sciadv.adh4327 · Cited by 431
Metadata
- Authors
- Hickman, D. A., Pawlowski, C. L., Sekhon, U. D. S., Marks, J., & Gupta, A. S.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2017-11-22
- Volume
- 30
- Issue
- 4
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W2770162756
- Cited by
- 583
- References
- 234
- FWCI
- 14.11
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.