The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Self‐Powered Pulse Sensor for Antidiastole of Cardiovascular Disease
Abstract
Cardiovascular diseases are the leading cause of death globally; fortunately, 90% of cardiovascular diseases are preventable by long‐term monitoring of physiological signals. Stable, ultralow power consumption, and high‐sensitivity sensors are significant for miniaturized wearable physiological signal monitoring systems. Here, this study proposes a flexible self‐powered ultrasensitive pulse sensor (SUPS) based on triboelectric active sensor with excellent output performance (1.52 V), high peak signal‐noise ratio (45 dB), long‐term performance (10 7 cycles), and low cost price. Attributed to the crucial features of acquiring easy‐processed pulse waveform, which is consistent with second derivative of signal from conventional pulse sensor, SUPS can be integrated with a bluetooth chip to provide accurate, wireless, and real‐time monitoring of pulse signals of cardiovascular system on a smart phone/PC. Antidiastole of coronary heart disease, atrial septal defect, and atrial fibrillation are made, and the arrhythmia (atrial fibrillation) is indicative diagnosed from health, by characteristic exponent analysis of pulse signals accessed from volunteer patients. This SUPS is expected to be applied in self‐powered, wearable intelligent mobile diagnosis of cardiovascular disease in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kleiger, R. E., Miller, J. P., Bigger, J. T., & Moss, A. J. (1987) · The American Journal of Cardiology · doi:10.1016/0002-9149(87)90795-8 · Cited by 3,995
A wearable and highly sensitive pressure sensor with ultrathin gold nanowires
Gong, S., Schwalb, W., Wang, Y., Chen, Y., Tang, Y., Si, J., Shirinzadeh, B., & Cheng, W. (2014) · Nature Communications · doi:10.1038/ncomms4132 · Cited by 2,064
Impact of Reduced Heart Rate Variability on Risk for Cardiac Events: The Framingham Heart Study
Tsuji, H., Larson, M. G., Venditti, F. J., Manders, E. S., Evans, J. C., Feldman, C. L., & Levy, D. (1996) · Circulation · doi:10.1161/01.cir.94.11.2850 · Cited by 1,762
On the Analysis of Fingertip Photoplethysmogram Signals
Elgendi, M. (2012) · Current Cardiology Reviews · doi:10.2174/157340312801215782 · Cited by 1,206
Wearable photoplethysmographic sensors—past and present
Tamura, T., Maeda, Y., Sekine, M., & Yoshida, M. (2014) · Electronics · doi:10.3390/electronics3020282 · Cited by 912
Sustainably powering wearable electronics solely by biomechanical energy
Wang, J., Li, S., Yi, F., Zi, Y., Lin, J., Wang, X., Xu, Y., & Wang, Z. L. (2016) · Nature Communications · doi:10.1038/ncomms12744 · Cited by 648
Self-citationBiodegradable triboelectric nanogenerator as a life-time designed implantable power source
Zheng, Q., Zou, Y., Zhang, Y., Liu, Z., Shi, B., Wang, X., Jin, Y., Ouyang, H., Li, Z., & Wang, Z. L. (2016) · Science Advances · doi:10.1126/sciadv.1501478 · Cited by 617
Self-citationIn Vivo Powering of Pacemaker by Breathing‐Driven Implanted Triboelectric Nanogenerator
Zheng, Q., Shi, B., Fan, F., Wang, X., Yan, L., Yuan, W., Wang, S., Liu, H., Li, Z., & Wang, Z. L. (2014) · Advanced Materials · doi:10.1002/adma.201402064 · Cited by 603
Self-citationLiu, Y., Norton, J. J. S., Qazi, R., Zou, Z., Ammann, K. R., Liu, H., Yan, L., Tran, P. L., Jang, K.-I., Lee, J. W., et al. (2016) · Science Advances · doi:10.1126/sciadv.1601185 · Cited by 397
Office, Home, and Ambulatory Blood Pressures as Predictors of Cardiovascular Risk
Niiranen, T. J., Mäki, J., Puukka, P., Karanko, H., & Jula, A. M. (2014) · Hypertension · doi:10.1161/hypertensionaha.114.03292 · Cited by 143
Cited by
The emergence of AI-based wearable sensors for digital health technology: a review
Shajari, S., Kuruvinashetti, K., Komeili, A., & Sundararaj, U. (2023) · Sensors · doi:10.3390/s23239498 · Cited by 535
Material choices for triboelectric nanogenerators: A critical review
Zhang, R., & Olin, H. (2020) · EcoMat · doi:10.1002/eom2.12062 · Cited by 533
Fully Bioabsorbable Natural‐Materials‐Based Triboelectric Nanogenerators
Jiang, W., Li, H., Liu, Z., Li, Z., Tian, J., Shi, B., Zou, Y., Ouyang, H., Zhao, C., Zhao, L., et al. (2018) · Advanced Materials · doi:10.1002/adma.201801895 · Cited by 449
Self-citationWearable and flexible sensors for user-interactive health-monitoring devices
Ha, M., Lim, S., & Ko, H. (2018) · Journal of Materials Chemistry B · doi:10.1039/c8tb01063c · Cited by 352
Self-powered cardiovascular electronic devices and systems
Zheng, Q., Tang, Q., Wang, Z. L., & Li, Z. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-020-0426-4 · Cited by 348
Self-citation
Metadata
- Authors
- Ouyang, H., Tian, J., Sun, G., Zou, Y., Liu, Z., Li, H., Zhao, L., Shi, B., Fan, Y., Fan, Y., Wang, Z. L., & Li, Z.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2017-09
- Volume
- 29
- Issue
- 40
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W2751242759
- Cited by
- 468
- References
- 11
- FWCI
- 16.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Self‐Powered Pulse Sensor for Antidiastole of Cardiovascular Disease. https://app.cochat.ai/papers/10.1002/adma.201703456
- The paper
- Ouyang, H., Tian, J., Sun, G., Zou, Y., Liu, Z., Li, H., Zhao, L., Shi, B., Fan, Y., Fan, Y., Wang, Z. L., & Li, Z. (2017). Self‐Powered Pulse Sensor for Antidiastole of Cardiovascular Disease. Advanced Materials. https://doi.org/10.1002/adma.201703456
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.