Giant Magnetic Heat Induction of Magnesium‐Doped γ‐Fe2O3 Superparamagnetic Nanoparticles for Completely Killing Tumors
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Magnetic fluid hyperthermia has been recently considered as a Renaissance of cancer treatment modality due to its remarkably low side effects and high treatment efficacy compared to conventional chemotheraphy or radiotheraphy. However, insufficient AC induction heating power at a biological safe range of AC magnetic field (Happl·fappl < 3.0–5.0 × 10 9 A m−1 s−1), and highly required biocompatibility of superparamagnetic nanoparticle (SPNP) hyperthermia agents are still remained as critical challenges for successful clinical hyperthermia applications. Here, newly developed highly biocompatible magnesium shallow doped γ‐Fe 2 O 3 (Mg 0.13‐γFe 2 O 3) SPNPs with exceptionally high intrinsic loss power (ILP) in a range of 14 nH m 2 kg−1, which is an ≈100 times higher than that of commercial Fe 3 O 4 (Feridex, ILP = 0.15 nH m 2 kg−1) at Happl·fappl = 1.23 × 10 9 A m−1 s−1 are reported. The significantly enhanced heat induction characteristics of Mg 0.13‐γFe 2 O 3 are primarily due to the dramatically enhanced out‐of‐phase magnetic susceptibility and magnetically tailored AC/DC magnetic softness resulted from the systematically controlled Mg 2+ cations distribution and concentrations in octahedral site Fe vacancies of γ‐Fe 2 O 3 instead of well‐known Fe 3 O 4 SPNPs. In vitro and in vivo magnetic hyperthermia studies using Mg 0.13‐γFe 2 O 3 nanofluids are conducted to estimate bioavailability and biofeasibility. Mg 0.13‐γFe 2 O 3 nanofluids show promising hyperthermia effects to completely kill the tumors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ferrite-based magnetic nanofluids used in hyperthermia applications
Sharifi, I., Shokrollahi, H., & Amiri, S. (2012) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2011.10.017 · Cited by 759
Cited by
Comprehensive understanding of magnetic hyperthermia for improving antitumor therapeutic efficacy
Liu, X., Zhang, Y., Wang, Y., Zhu, W., Li, G., Ma, X., Zhang, Y., Chen, S., Tiwari, S., Shi, K., et al. (2020) · Theranostics · doi:10.7150/thno.40805 · Cited by 719
Magnetic nanoparticles in biomedical applications: A review
Materón, E. M., Miyazaki, C. M., Carr, O., Joshi, N., Picciani, P. H. S., Dalmaschio, C. J., Davis, F., & Shimizu, F. M. (2021) · Applied Surface Science Advances · doi:10.1016/j.apsadv.2021.100163 · Cited by 456
Said, Z., Sundar, L. S., Tiwari, A. K., Ali, H. M., Sheikholeslami, M., Bellos, E., & Babar, H. (2022) · Physics Reports · doi:10.1016/j.physrep.2021.07.002 · Cited by 391
Recent advances in magnetic fluid hyperthermia for cancer therapy
Das, P., Colombo, M., & Prosperi, D. (2019) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2018.10.051 · Cited by 329
Biomedical applications of metallic nanoparticles in cancer: Current status and future perspectives
Khursheed, R., Dua, K., Vishwas, S., Gulati, M., Jha, N. K., Aldhafeeri, G. M., Alanazi, F. G., Goh, B. H., Gupta, G., Paudel, K. R., et al. (2022) · Biomedicine & Pharmacotherapy · doi:10.1016/j.biopha.2022.112951 · Cited by 286
Mild Magnetic Hyperthermia-Activated Innate Immunity for Liver Cancer Therapy
Pan, J., Xu, Y., Wu, Q., Hu, P., & Shi, J. (2021) · Journal of the American Chemical Society · doi:10.1021/jacs.1c02537 · Cited by 224
Chao, Y., Chen, G., Liang, C., Xu, J., Dong, Z., Han, X., Wang, C., & Liu, Z. (2019) · Nano Letters · doi:10.1021/acs.nanolett.9b00579 · Cited by 222
Albarqi, H. A., Wong, L. H., Schumann, C., Sabei, F. Y., Korzun, T., Li, X., Hansen, M. N., Dhagat, P., Moses, A. S., Taratula, O., et al. (2019) · ACS Nano · doi:10.1021/acsnano.8b06542 · Cited by 215
Genetically engineered magnetic nanocages for cancer magneto-catalytic theranostics
Zhang, Y., Wang, X., Chu, C., Zhou, Z., Chen, B., Pang, X., Lin, G., Lin, H., Guo, Y., Ren, E., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-19061-9 · Cited by 168
Rational Design of Biomaterials to Potentiate Cancer Thermal Therapy
Zhu, Y., Li, Q., Wang, C., Hao, Y., Yang, N., Chen, M., Ji, J., Feng, L., & Liu, Z. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00822 · Cited by 163
Tapeinos, C., Tomatis, F., Battaglini, M., Larrañaga, A., Marino, A., Telleria, I. A., Angelakeris, M., Debellis, D., Drago, F., Brero, F., et al. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201900612 · Cited by 54
Multifunctional Magnetic Nanoparticles for Dynamic Imaging and Therapy
Ko, M. J., Hong, H., Choi, H., Kang, H., & Kim, D. (2022) · Advanced NanoBiomed Research · doi:10.1002/anbr.202200053 · Cited by 29
Metadata
- Authors
- Jang, J., Lee, J., Seon, J., Ju, E., Kim, M., Kim, Y. I., Kim, M. G., Takemura, Y., Arbab, A. S., Kang, K. W., Park, K. H., Paek, S. H., & Bae, S.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2017-12-20
- Volume
- 30
- Issue
- 6
- Pages
- e1806347-e1806347
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W2778505746
- Cited by
- 133
- References
- 1
- FWCI
- 4.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.