Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.

Personalized Hydrogels for Engineering Diverse Fully Autologous Tissue Implants

Abstract

Despite incremental improvements in the field of tissue engineering, no technology is currently available for producing completely autologous implants where both the cells and the scaffolding material are generated from the patient, and thus do not provoke an immune response that may lead to implant rejection. Here, a new approach is introduced to efficiently engineer any tissue type, which its differentiation cues are known, from one small tissue biopsy. Pieces of omental tissues are extracted from patients and, while the cells are reprogrammed to become induced pluripotent stem cells, the extracellular matrix is processed into an immunologically matching, thermoresponsive hydrogel. Efficient cell differentiation within a large 3D hydrogel is reported, and, as a proof of concept, the generation of functional cardiac, cortical, spinal cord, and adipogenic tissue implants is demonstrated. This versatile bioengineering approach may assist to regenerate any tissue and organ with a minimal risk for immune rejection.

Overview

Integrity signals

Registry

Crossref · 10.1002/adma.201803895

Cites

49 of 49 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 49 references

Cited by

See all 128

Metadata

Authors
Edri, R., Gal, I., Noor, N., Harel, T., Fleischer, S., Adadi, N., Green, O., Shabat, D., Heller, L., Shapira, A., Gat‐Viks, I., Peer, D., & Dvir, T.
Affiliations
  • Tel Aviv University (IL)
  • Assaf Harofeh Medical Center (IL)
Corresponding author
Dvir, Tal
Venue
Advanced Materials
Publisher
Wiley
Published
2018-11-08
Volume
31
Issue
1
Pages
e1803895-e1803895
ISSN
  • 0935-9648 (ISSN-L)
  • 1521-4095
OpenAlex
W2899651107
Cited by
128
References
49
Citations by year
2026: 6 · 2025: 9 · 2024: 15 · 2023: 14 · 2022: 15 · 2021: 20 · 2020: 27 · 2019: 21 · 2018: 1
FWCI
6.52
Type
journal article
Language
en
Open access
closed
Locations
  • Advanced Materials (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • European Research Council (637943)
  • Ministry of Science, Technology and Space (3‐12587)
Topics
  • Physical Sciences › Materials Science › Biomaterials › Hydrogels: synthesis, properties, applications
  • Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
  • Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
Keywords
thermosensitive hydrogel, induced pluripotent stem cells, omental tissue, immune rejection, 3D tissue engineering, cardiac regeneration, spinal cord regeneration, cell differentiation, personalized medicine
MeSH terms
Animals, Cell Differentiation, Extracellular Matrix, Humans, Mice, Inbred C57BL, Omentum, Swine, Transplantation, Autologous, Prostheses and Implants, Hydrogels, Tissue Engineering, Myocytes, Cardiac, Endothelial Cells, Mice, Tissue Scaffolds, Induced Pluripotent Stem Cells, Cellular Reprogramming

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Personalized Hydrogels for Engineering Diverse Fully Autologous Tissue Implants. https://app.cochat.ai/papers/10.1002/adma.201803895
The paper
Edri, R., Gal, I., Noor, N., Harel, T., Fleischer, S., Adadi, N., Green, O., Shabat, D., Heller, L., Shapira, A., Gat‐Viks, I., Peer, D., & Dvir, T. (2019). Personalized Hydrogels for Engineering Diverse Fully Autologous Tissue Implants. Advanced Materials. https://doi.org/10.1002/adma.201803895

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.