The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
A Highly Responsive Organic Image Sensor Based on a Two‐Terminal Organic Photodetector with Photomultiplication
Abstract
Highly responsive organic image sensors are crucial for medical imaging applications. To enhance the pixelwise photoresponse in an organic image sensor, the integration of an organic photodetector with amplifiers, or the use of a highly responsive organic photodetector without an additional amplifying component, is required. The use of vertically stacked, two‐terminal organic photodetectors with photomultiplication is a promising approach for highly responsive organic image sensors owing to their simple two‐terminal structure and intrinsically large responsivity. However, there are no demonstrations of an imaging sensor array using organic photomultiplication photodetectors. The main obstacle to a sensor array is the weak‐light sensitivity, which is limited by a relatively large dark current. Herein, a highly responsive organic image sensor based on monolithic, vertically stacked two‐terminal pixels is presented. This is achieved using pixels of a vertically stacked diode‐type organic photodetector with photomultiplication. Furthermore, applying an optimized injection electrode and additionally stacked rectifying layers, this two‐terminal device simultaneously demonstrates a high responsivity (>40 A W−1), low dark current, and high rectification under illumination. An organic image sensor based on this device with an extremely simple architecture exhibits a high pixel photoresponse, demonstrating a weak‐light imaging capability even at 1 µW cm−2.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
The rise of plastic bioelectronics
Someya, T., Bao, Z., & Malliaras, G. G. (2016) · Nature · doi:10.1038/nature21004 · Cited by 1,884
Self-citationUltraflexible organic photonic skin
Yokota, T., Zalar, P., Kaltenbrunner, M., Jinno, H., Matsuhisa, N., Kitanosako, H., Tachibana, Y., Yukita, W., Koizumi, M., & Someya, T. (2016) · Science Advances · doi:10.1126/sciadv.1501856 · Cited by 1,024
Self-citationA skin-inspired organic digital mechanoreceptor
Tee, B. C.-K., Chortos, A., Berndt, A., Nguyen, A. K., Tom, A., McGuire, A., Lin, Z. C., Tien, K., Bae, W.-G., Wang, H., et al. (2015) · Science · doi:10.1126/science.aaa9306 · Cited by 882
Optical properties of human skin
Lister, T., Wright, P. A., & Chappell, P. H. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.9.090901 · Cited by 467
Noninvasive pulse oximetry utilizing skin reflectance photoplethysmography
Mendelson, Y., & Ochs, B. D. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.7286 · Cited by 251
Cited by
Recent Progress in Organic Photodetectors and their Applications
Ren, H., Chen, J., Li, Y., & Tang, J. (2021) · Advanced Science · doi:10.1002/advs.202002418 · Cited by 536
Recent Progress on Broadband Organic Photodetectors and their Applications
Zhao, Z., Xu, C., Niu, L., Zhang, X., & Zhang, F. (2020) · Laser & Photonics Reviews · doi:10.1002/lpor.202000262 · Cited by 290
Emerging New-Generation Photodetectors Based on Low-Dimensional Halide Perovskites
Wang, Y., Song, L., Chen, Y., & Huang, W. (2020) · ACS Photonics · doi:10.1021/acsphotonics.9b01233 · Cited by 156
Metadata
- Authors
- Wu, Y., Fukuda, K., Yokota, T., & Someya, T.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2019-09-09
- Volume
- 31
- Issue
- 43
- Pages
- e1903687-e1903687
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W2972559297
- Cited by
- 190
- References
- 6
- FWCI
- 7.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.