Cited by 251Non-Invasive Vital Sign MonitoringOptical Imaging and Spectroscopy TechniquesAnalytical Chemistry and Sensors

Noninvasive pulse oximetry utilizing skin reflectance photoplethysmography

Mendelson, Y., Ochs, B.D.·1988·IEEE Transactions on Biomedical Engineering

Abstract

The major concern in developing a sensor for reflectance pulse oximetry is the ability to measure large and stable photoplethysmograms from light which is backscattered from the skin. Utilizing a prototype optical reflectance sensor, locally heating the skin is shown to increase the pulsatile component of the reflected photoplethysmograms. Additional improvements to signal-to-noise ratio were achieved by increasing the active area of the photodetector and optimizing the separation distance between the light source and photodetector. The results from a series of in vivo studies to evaluate a prototype skin-reflectance pulse oximeter in humans are presented.>

Integrity signals

Registry

Crossref · 10.1109/10.7286

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

The citation lists haven’t been fetched yet

References 9 · Cited by 251

Authors
Mendelson, Y., & Ochs, B. D.
Affiliations
Worcester Polytechnic Institute (US)
Venue
IEEE Transactions on Biomedical Engineering
Published
1988-10
Volume
35
Issue
10
Pages
798-805
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2050755789
Cited by
251
References
9
Citations by year
2026: 4 · 2025: 1 · 2024: 6 · 2023: 12 · 2022: 16 · 2021: 16 · 2020: 19 · 2019: 8 · 2018: 12 · 2017: 7 · 2016: 15 · 2015: 10 · 2014: 11 · 2013: 8 · 2012: 7
FWCI
1.93
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
  • Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
Keywords
pulse oximetry, photoplethysmogram, skin heating, signal-to-noise ratio, in vivo validation
MeSH terms
Adult, Equipment Design, Female, Hot Temperature, Humans, Light, Male, Oximetry, Oxygen, Plethysmography, Skin Temperature

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review